UAT 363 Unmanned Aircraft Systems Technology for Transportation and Smart Warehousing

Worksheet 3 Scanning a mock rack

Lab 12 hAssesses CLO2

Objective

Plan cycle counting, set up and measure an indoor positioning system, and fly rack scans to measure the tag read rate

Equipment and materials

  • Mock rack with a barcode or AprilTag on every slot
  • Small indoor drone with propeller guards
  • Indoor positioning system (UWB or motion capture)
  • PX4 and its external-position guide
  • Python and the module 3 example code

Safety

  • Fly in a netted closed area; observers stay outside the net
  • Use propeller guards and set a geofence or height limit before autonomous flight
  • A pilot is ready to take manual control or kill the motors at once

Steps

  1. Set up the mock rack with a barcode or AprilTag on every slot
  2. Apply Example 1 to the hospital or lab store size; plan cycle counting
  3. Install indoor positioning, feed positions to PX4 per the guide, measure error against reference points
  4. Apply Example 2 to real UWB ranges from several points; record the error
  5. Fly manual or automatic scans in the closed area; record the successful read rate

Record of results

Table 1 Rack layout and cycle-counting plan
ItemStore or lab valueResultUnit
Table 2 Indoor position error against reference points
Reference pointTrue position x, y (m)Estimated position x, y (m)Error (cm)Source (UWB, motion capture or computed from ranges)
Table 3 Tag read success rate
RunMode (manual or automatic)Tags read / totalRead rate (%)Causes of missed reads

Questions

  1. From Table 1, if one aisle is cycle-counted each day, how often is every location recounted, and why do drones suit cycle counting better than a once-a-year full stock take?

  2. Which reference point in Table 2 has the largest error? Explain the likely causes, and what happens if a UWB anchor position is surveyed 30 cm wrong?

  3. Why does 2D positioning need at least 3 UWB anchors that are not in a straight line, and what does a fourth anchor add?

  4. If your read rate is below 100%, can you conclude that the unread slots are empty? What should you do before concluding?

  5. Why must GNSS-dependent flight modes not be used indoors, and how, and at what rate according to the guide, did the group feed position into PX4?

Check before you hand in

What to hand in

  • Rack layout and counting plan
  • Indoor position error table
  • UWB position calculation
  • Read rate with causes of missed reads
  • Lab notebook

CLO2 Apply drones and IoT in smart warehouses. (CLOs are a web-team draft; the course owner sets the final ones.)

Instructors: answers and teaching notes for this worksheet are in the teaching pack