UAT 452 Remote Sensing and Geographic Information Systems for UAS

Worksheet 2 Reflectance calibration and thermal reading

Lab 6 hAssesses CLO1

Objective

Convert DN to reflectance with two panels and show how emissivity affects thermal-camera temperatures

Equipment and materials

  • Drone with multispectral and thermal cameras
  • Two reference panels of known reflectance
  • Contact thermometer
  • Water container, wet soil and dry soil
  • Camera vendor software, Python and the module 2 example code

Safety

  • Fly within CAAT conditions in visual line of sight under the lecturer's control; keep people clear
  • Inspect batteries before flight and do not touch the panel surfaces

Steps

  1. Lay two panels in the test area and capture them with the multispectral camera before and after flight
  2. Read panel DN in each band, compute a and b with Example 1 and convert vegetation, water and soil pixels
  3. Compare the reflectance with the vendor software's values
  4. Take thermal images of water, wet soil and dry soil whose temperatures are measured with the contact thermometer
  5. Adjust emissivity in the software and compare values before and after with the true temperatures, against Example 2

Record of results

Table 1 Panel DN and the a and b of each band
BandDark panel DN (before/after)Bright panel DN (before/after)ab
Table 2 Own reflectance against the vendor software
SurfaceBandDNComputed reflectanceSoftware valueDifference
Table 3 Thermal-camera temperatures before and after emissivity adjustment
SurfaceTrue temperature, thermometer (°C)Reading with ε = 1 (°C)ε setReading after adjustment (°C)

Questions

  1. How much do the a values from the pre-flight and post-flight panels differ? If a lot, how does this affect vegetation reflectance, and which should you use?

  2. On which surface do your reflectance and the vendor software differ most? Explain possible causes such as the downwelling light sensor, shadow on a panel or pixel choice.

  3. With ε = 1, which surface reads furthest from its true temperature? Does this match the trend in Example 2, and how much error remains after adjusting ε, and why?

  4. A staff member sees dry soil cooler than water in a thermal image taken with ε = 1. Is that conclusion reliable? Answer from Table 3.

Check before you hand in

What to hand in

  • a and b for every band
  • Reflectance versus vendor software table
  • Temperatures before and after emissivity adjustment against true values

CLO1 Explain remote sensing and multispectral data. (CLOs are a web-team draft; the course owner sets the final ones.)

Instructors: answers and teaching notes for this worksheet are in the teaching pack