UAT 455 Sensor, Camera and Thermal Imaging Technology for UAS
Worksheet 3 Lens calibration and band alignment
Objective
Perform geometric calibration by Zhang's method, compute the effect of distortion, check band misalignment, and calibrate radiometrically to compute NDVI
Equipment and materials
- Checkerboard printed on a flat rigid board
- The department's camera, and a multispectral camera if available
- Computer with Python, OpenCV and the MicaSense code
- Reference-panel images from a multispectral camera, or the sample images in the MicaSense code
Safety
- Mainly desk and tripod work
- If flying at two heights, fly within CAAT conditions in visual line of sight and keep people clear
Steps
- Photograph the checkerboard from at least 15 angles covering the image edges
- Calibrate with OpenCV; record focal length, principal point, k1 and reprojection error
- Compute the edge shift with Example 1
- If a multispectral camera is available, shoot at two heights and compare band misalignment with Example 2
- Align bands with the MicaSense code and compare the vegetation index along edges before and after alignment
- Convert images to reflectance from the reference-panel image with Example 3, then compute NDVI for canopy, mud and water with Example 4
Record of results
| Item (fx, fy, cx, cy, k1, reprojection error, shift at x = 0.1, 0.3, 0.6) | Value | Unit |
|---|---|---|
| Height (m) | Calculated shift (px) | Measured shift (px) | Edge index before alignment | Edge index after alignment |
|---|---|---|---|---|
| Surface | Red signal | NIR signal | Red reflectance | NIR reflectance | NDVI (usable pixels) |
|---|---|---|---|---|---|
Questions
Is your k1 positive or negative, what kind of distortion is that, and what happens at the image edges if it is not corrected before stitching?
Does the misalignment you measured at two heights follow f b / Z, and why can bands not be aligned with one constant offset?
If a thin cloud cuts the DLS reading to 80% of its value at the panel capture and you skip the DLS correction, how are reflectance and NDVI affected?
NDVI at a spot fell by 0.06 between two days, but one day has no panel record and a plot has two of five pixels empty. Can you conclude the forest declined, and how should you report it?
From your results, when should the camera be recalibrated?
Check before you hand in
What to hand in
- Calibration table with reprojection error
- Distortion shift table
- Before and after band alignment images (if a camera is available)
- Conclusion on when to recalibrate
- Table of reflectance and NDVI for each surface type