UAT 459 UAS, Internet of Things and Smart Warehouse Systems

Worksheet 3 Localization and slot inspection on a mock rack

Lab 8 hAssesses CLO2

Objective

Convert label images to location codes correctly on both sides, reduce wrong slots with beam labels, and evaluate slot inspection with precision and recall

Equipment and materials

  • A mock rack of at least three bays and two levels, with beam location labels and box labels
  • A camera on a cart at known positions, and a tape measure
  • A range sensor such as a single-point LiDAR or ToF sensor
  • Computer with the module 3 example code

Safety

  • No flying; fix the mock rack firmly and keep heavy items off the top level
  • Never point laser range sensors at anyone's eyes

Steps

  1. Measure the true x and z of every label and record the correct location codes
  2. Photograph from the cart facing left and right, convert with the locate function and check the sign for each side
  3. Add random errors of 0.05, 0.10 and 0.20 m and compare wrong-slot rates with Example 2
  4. Change the code to measure relative to the beam label in the same image and test again
  5. Arrange empty slots, overhanging boxes and low boxes, measure every slot and compute precision and recall as in Example 3

Record of results

Table 1 Computed versus true location codes
Image no.Camera side (L/R)True x (m)Computed x (m)Computed codeTrue code
Table 2 Wrong-slot rate before and after beam-label anchoring
Added error σ (m)Labels testedWrong beforeWrong after anchoringRate before (%)Rate after (%)
Table 3 Confusion table of slot inspection
ClassTPFPFNPrecisionRecall

Questions

  1. When you used the same sign for cameras on both sides, which side went wrong and how? Why is this error systematic rather than random?

  2. Which label in Table 1 was closest to a slot boundary? From Table 2, how did beam-label anchoring change the wrong-slot rate, and why does it work better than buying a more expensive positioning system?

  3. From Table 3, what in your rack caused slots wrongly called empty and empty slots that were missed? To catch overhanging pallets, should the threshold favour precision or recall, and why?

  4. Why must an "empty" result from the range sensor never adjust the WMS directly? Answer from the errors in your own test.

Check before you hand in

What to hand in

  • Computed versus true location codes
  • Wrong-slot rate before and after beam-label anchoring
  • Confusion table with precision and recall
  • Recommended threshold for overhanging pallets

CLO2 Design drone inventory-counting and stock-inspection missions, including rack localization and indoor route planning. (CLOs are a web-team draft; the course owner sets the final ones.)

Instructors: answers and teaching notes for this worksheet are in the teaching pack