UAT 465 UAS Technology for Smart Farming and Precision Agriculture
Worksheet 2 Surveying a field and calibrating reflectance
Objective
Fly a multispectral survey in a suitable time window and convert pixel values to reflectance comparable across days
Equipment and materials
- Drone with multispectral camera and downwelling light sensor
- Reflectance reference panel
- MicaSense processing software or code
- Python and the module 2 example code
- Spare batteries and a fire-safe battery bag
Safety
- Fly within CAAT conditions in visual line of sight; keep people clear
- Check batteries before flight and keep them in fire-safe bags
- When working in the field under strong sun, drink water and rest in shade
Steps
- Compute the flight window for survey day with Example 2
- Photograph the reference panel before and after flight
- Fly the field as planned in module 1; record light and cloud
- Convert pixels to reflectance with MicaSense software or code; check sample points against the Example 1 hand calculation
- Find abnormally bright strips and explain whether light or plants caused them
- Stitch an orthomosaic, read the share of calibrated images in the quality report, and compare the mosaic with the earlier check points using the limit in Example 4
Record of results
| Time | Sun elevation (deg) | Fly? | Sky and cloud | Notes |
|---|---|---|---|---|
| Point | DN | Light E from sensor | Uncorrected reflectance | Corrected reflectance | Software value |
|---|---|---|---|---|---|
| Item | Value | Criterion | Pass? |
|---|---|---|---|
Questions
How does your survey day's flight window differ from 15 January in Example 2, why, and when should you fly the repeat survey next season?
By what percentage does the uncorrected reflectance of a point captured under reduced light differ from the corrected value? If you mapped uncorrected values, how would the fertiliser decision go wrong?
Did your abnormally bright strips come from light or from the crop, and what evidence confirms it?
If the quality report says 94.7% of images were calibrated, what should your group do next, and when should you refly?
Check before you hand in
What to hand in
- Flight window and flight log
- Field reflectance images
- Hand-calculation comparison
- Explanation of abnormal strips
- Mosaic quality check
- Lab notebook