การวัดทางไฟฟ้าและความปลอดภัยทางไฟฟ้า
Multimeters, oscilloscopes, current/voltage measurement and laboratory safety
Overview
Every assembly, repair and test job on a drone depends on measurement: are the cells balanced, how much current does a motor draw, where is a wire broken, does the flight controller's signal reach the ESC intact? A measurement taken the wrong way gives the wrong number, and can also destroy the meter, cause a spark or injure the person measuring. This unit summarises the multimeter and the oscilloscope, reading accuracy specifications, measuring high currents, and electrical safety rules in the laboratory.
The digital multimeter
A multimeter measures several quantities; the key is connecting it the right way.
| Measurement | Connection | First |
|---|---|---|
| Voltage | Parallel, across two points | Choose DC or AC; leads in the V jack |
| Current | Series; break the circuit so current flows through the meter | Move the lead to the A or mA jack and check the meter's fuse rating |
| Resistance and continuity | Across the part or wire | Always remove power first |
| Diode | Across the diode | Power off; read the forward voltage |
To measure current, the meter passes it through a small internal resistor, the shunt, and measures the voltage across it. That voltage, the burden voltage, is taken away from the circuit under test and can upset low-voltage devices. After measuring current, move the lead back to the V jack immediately; forget, and the next voltage measurement across a battery turns the meter into a short circuit.
Reading accuracy
Makers state accuracy as ±(a% of reading + n digits), where a digit is one unit of the last displayed place on that range. The two parts add, so a reading is really a range, not a single point.
Example 1: measuring a camera's current
Assume the current range is specified at ±(0.8% + 3 digits), shows three decimal places and reads 1.234 A, and that the meter's shunt on this range is about 0.1 Ω (assumed).
- Percentage part: 0.008 × 1.234 ≈ 0.0099 A.
- Digit part: 3 × 0.001 = 0.003 A.
- Total ±0.0129 A, so the true value lies between about 1.221 and 1.247 A.
Measuring 2 A through a 0.1 Ω shunt drops 2 × 0.1 = 0.2 V inside the meter and heats it by 22 × 0.1 = 0.4 W. On a 5 V circuit, losing 0.2 V is 4%, enough to reset a camera. High currents of motors or the whole aircraft are therefore measured with a DC clamp meter, which needs no break in the circuit, or with a power module whose very low-value shunt stays permanently in the main lead.
Measurement categories (CAT) and instrument ratings
IEC 61010-1 groups measurement locations by the transient overvoltages they can experience; the closer to the mains supply, the more dangerous. CAT II covers equipment plugged into mains outlets, such as chargers; CAT III, building installations; CAT IV, the utility connection. Circuits on the drone and its battery sit outside the mains system, but when measuring at a charger or an outlet, use a meter and leads rated for that CAT and at least that voltage. Replace leads with cracked insulation or loose tips immediately.
The oscilloscope
A multimeter shows an average or RMS value and hides the waveform. An oscilloscope plots voltage against time, so it reveals PWM, digital signals, noise and spikes. Terms to know:
- time/div and volts/div: the size of one screen division on each axis; count divisions and multiply.
- Trigger: the condition that starts each sweep at the same point, such as a rising edge at 1.5 V, giving a stable picture.
- Bandwidth: the highest frequency displayed without significant attenuation. It must be several times the signal frequency so square edges are not rounded.
- Sample rate: points captured per second. You need several points within each bit or pulse.
- 10× probes load the circuit less; set the scope's probe factor to match.
Example 2: setting up a scope for DShot600
DShot600 sends 600,000 bits per second, so one bit lasts 1 ÷ 600,000 ≈ 1.67 µs (the rate named in the protocol, per the ArduPilot documentation).
- For at least 10 samples per bit, the sample rate must be at least 10 ÷ 1.67 µs = 6 million samples per second (6 MS/s).
- At 5 µs/div, ten divisions show 50 µs, about 30 bits, so individual bit shapes and the gap between commands fit on one screen.
- Trigger on the rising edge of the DShot line, with the probe ground clipped to the flight controller's ground.
Heavily rounded edges or sharp spikes often point to long signal leads or poor grounding, which is why the ArduPilot documentation recommends a slower DShot rate for aircraft with long signal wires.
Electrical safety in the laboratory
There are two main hazards: electric shock when current passes through the body, which 230 V mains can make fatal, and fire or arcing from high-current short circuits, which drone batteries can cause despite their modest voltage. Basic rules:
- Remove rings, watches and metal jewellery before working on batteries.
- Connect the battery last and disconnect it first; cover unused lead ends.
- Power up for the first time through a smoke stopper or a current-limited supply.
- Remove propellers for every bench test.
- A bench oscilloscope's probe ground is usually tied to mains earth; clip it only to circuit ground.
- Never open a charger or power supply while it is plugged in, and use outlets protected by a residual-current device.
Fault-finding should follow an order: inspect by eye, then with power off check continuity and look for a short between positive and negative, and only then power up and compare measured voltages with values calculated from the schematic.
Common pitfalls
- Measuring voltage with the lead still in the A jack.
- Measuring resistance in a live circuit.
- Using a meter or leads rated below the CAT of the measurement point.
- Ignoring accuracy when comparing values that differ only slightly, such as cell voltages.
- Forgetting burden voltage, so the circuit under test misbehaves.
- A probe factor that does not match the probe, giving readings ten times off.
- Clipping the probe ground to the wrong point and shorting through mains earth.
Continue in the lessons
- UAT 103 Module 5: Instruments and electrical safety: multimeter connections, accuracy, CAT ratings, reading an oscilloscope and handling lithium batteries.
Key references
- International Electrotechnical Commission. (2010). Safety requirements for electrical equipment for measurement, control, and laboratory use: Part 1. General requirements (IEC 61010-1:2010).
- Fluke Corporation. ABCs of multimeter safety [Application note; copy hosted by distributor TEquipment]. link
- Horowitz, P., & Hill, W. (2015). The art of electronics (3rd ed.). Cambridge University Press.
- ArduPilot Dev Team. Power module / battery monitor. ArduPilot Copter documentation. link
- ArduPilot Dev Team. ESCs and motors; DShot ESCs. link