Teaching pack · UAT 103
A 15-week teaching plan, 5 worksheets, a scoring rubric and a map from the course description to the lessons, for instructors to evaluate and adapt before teaching.
Coverage of the course description
The lessons fully teach 10 of 10 description topics. Each topic lists the modules and lesson sections that teach it, and incomplete topics say what is missing.
| Description topic | Modules | Where it is taught | Status |
|---|---|---|---|
| Electrical quantities and units, voltage, current, resistance and electrical power | M1 | Module 1: Charge, current and voltage · Resistance and Ohm's law · Power and energy · Wire resistance | Covered |
| Basic direct current and alternating current circuits | M1M2M3 | Modules 1–2: DC circuits from supplies and batteries · Module 3: Alternating current, Capacitors, RC circuits and the time constant, and Inductors | Covered |
| Fundamental electrical laws | M1M2 | Module 1: Resistance and Ohm's law · Module 2: Kirchhoff's laws (KCL and KVL) | Covered |
| Series and parallel circuits | M2 | Module 2: Series and parallel circuits · The voltage divider · Battery cell arrangements (4S2P) | Covered |
| Basic electrical and electronic components: resistors, capacitors, diodes, transistors and introductory semiconductor devices | M1M3M4 | Module 1: Resistor power ratings and fuses · Module 3: Capacitors and inductors · Module 4: Diodes and LEDs · Transistors and MOSFETs · Voltage regulators and BECs · Op-amp amplifiers | Covered |
| Basic analog and digital signals | M2M3M4 | Module 4: Analog and digital signals (logic levels and noise margins, sampling and the Nyquist criterion, aliasing, ADC resolution, Examples 7–8) · Pulse-width modulation (PWM) · The ESC and control signals (PWM versus DShot) · Module 2: the voltage divider into an ADC · Module 3: the low-pass filter | Covered |
| Reading simple electrical symbols and circuit diagrams | M2 | Module 2: Reading symbols and circuit diagrams | Covered |
| Use of multimeters and basic measuring instruments | M3M5 | Module 3: oscilloscope peak, period and RMS in the lab · Module 5: The multimeter, Reading meter accuracy, Measurement categories (CAT) and The oscilloscope | Covered |
| Basic circuit inspection | M5 | Module 5: Basic circuit inspection and the example of a voltage divider giving the wrong value | Covered |
| Safety practices in electrical and electronic work | M1M5 | Module 1: Fuses and overcurrent protection · Module 5: Electrical safety and Charging and handling lithium batteries | Covered |
Weekly teaching plan
| Week | Topic | Pre-class | Lecture | Lab | Evidence |
|---|---|---|---|---|---|
| 1 M1 | Charge, current, voltage and electrical units | Read module 1 up to 'Charge, current and voltage' | Electricity as a drone's circulation system; meaning and units of charge, current and voltage | Worksheet 1 part A: set the supply current limit; measure voltage and current of a 100 Ω resistor from 1 to 10 V | Table of measured voltage and current |
| 2 M1 | Ohm's law, power and energy | Read 'Resistance and Ohm's law' and 'Power and energy'; work Examples 1–2 by hand | Size an LED current-limiting resistor and a resistor's power rating | Worksheet 1 part B: plot I against V and compare the slope with 1/R; build the LED circuit of Example 1 and measure its current | I-V graph and LED current against calculation |
| 3 M1 | Wire resistance, fuses and overcurrent protection | Read 'Wire resistance' and 'Fuses'; work Example 3 and take the module 1 quiz | Voltage drop and heat in a drone's main leads; choosing a fuse | Worksheet 1 part C: pass 10 A through 1 m of different wire gauges; measure the drop and compare resistance with the formula | Worksheet 1 report and quiz result |
| 4 M2 | Symbols, circuit diagrams, series and parallel circuits | Read module 2 'Reading symbols and circuit diagrams' and 'Series and parallel circuits'; work Example 1 | Reading simple schematics; equivalent resistance of series and parallel circuits | Worksheet 2 part A: build series and parallel circuits of three resistors from a schematic; measure voltage and current everywhere | Hand-drawn schematic and measurement table |
| 5 M2 | Kirchhoff's laws and the voltage divider | Read 'Kirchhoff's laws' and 'The voltage divider'; work Examples 2–4 | KVL and KCL on a distribution board; a voltage divider for an ADC | Worksheet 2 part B: check KCL and KVL from readings; design and build a divider for a 4S battery giving at most 3.3 V | KCL/KVL check and divider output against calculation |
| 6 M2 | Series and parallel battery cell arrangements | Read 'Battery cell arrangements'; work Example 5 and take the module 2 quiz | Voltage and capacity of a 4S2P pack; what cell imbalance means | Worksheet 2 part C: check a sample battery with a cell checker; record each cell and find the largest difference | Worksheet 2 report and quiz result |
| 7 M3 | Alternating current: peak, period, frequency and RMS | Read module 3 'Electricity that changes with time' and 'Alternating current'; work Example 1 | Thai mains, 50 Hz and nominally 230 V; peak versus RMS | Worksheet 3 part A: view a function-generator signal on the oscilloscope; read peak, period and frequency and compare with the multimeter RMS | Oscilloscope readings against the multimeter |
| 8 M3 | Capacitors, RC circuits and the time constant | Read 'Capacitors' and 'RC circuits and the time constant'; work Example 2 | The capacitor at the ESC power input; charging to 63% | Worksheet 3 part B: build an RC circuit with 10 kΩ and 100 µF; apply a slow square wave and compare the time to 63% with τ = 1 s | Oscilloscope capture and measured τ |
| 9 M3 | Low-pass filter, inductors; midterm | Read 'The low-pass filter' and 'Inductors'; work Examples 3–4; review modules 1–3 and take the module 3 quiz | Midterm examination (modules 1–3) | Worksheet 3 part C: feed sine waves of several frequencies into an RC filter and find where amplitude falls to about 70.7% | Worksheet 3 report and midterm score |
| 10 M4 | Diodes, LEDs, transistors and MOSFETs | Read module 4 'Diodes and LEDs' and 'Transistors and MOSFETs'; work Examples 1–2 | Reverse-polarity diodes and heat in an ESC MOSFET | Worksheet 4 part A: measure forward voltage of silicon and Schottky diodes and several LED colours in diode mode | Forward-voltage table |
| 11 M4 | Pulse-width modulation (PWM) | Read the PWM section; work Example 3 and run the module 4 lesson code | Duty cycle and average voltage; switching a MOSFET instead of dropping voltage in a resistor | Worksheet 4 part B: generate PWM on a microcontroller to drive a MOSFET and a small DC motor; measure duty cycle and average voltage | Duty cycle against average voltage, with calculations |
| 12 M4 | ESCs, control signals, regulators, op-amps, and analog and digital signals | Read 'The ESC and control signals', 'Voltage regulators and BECs', 'Op-amp amplifiers' and 'Analog and digital signals'; work Examples 4–8 and take the module 4 quiz | 1000–2000 µs pulses versus DShot; linear versus switching regulators; amplifying a current-sense signal; logic levels, sampling and ADC resolution | Worksheet 4 part C: connect a servo tester to an ESC with propellers removed and view the pulses on the oscilloscope | Worksheet 4 report and quiz result |
| 13 M5 | Multimeters, accuracy and measurement categories (CAT) | Read module 5 'The multimeter', 'Reading meter accuracy' and 'Measurement categories'; work Example 1 | Connecting the meter for each quantity; reading error from the specification; the hazard of measuring current in the wrong jack | Worksheet 5 part A: practise measuring cell voltages through the balance lead and current in LED and small-motor circuits, then return the lead to the V jack | Measurements with the meter's error band |
| 14 M5 | Circuit inspection, oscilloscopes and battery safety | Read 'Basic circuit inspection', 'The oscilloscope', 'Electrical safety' and 'Charging and handling lithium batteries'; work Example 2 and take the module 5 quiz | A fault-finding sequence, the scope ground, and battery charging practice | Worksheet 5 part B: rehearse measuring servo-tester pulses, continuity checks on a harness, and the charging checklist | Signed charging checklist and quiz result |
| 15 M5 | Practical assessment: instruments and safety | Review all labs and the safety checklists | Course wrap-up and practical assessment criteria | Five-station practical from the module 5 lab box: cell voltages, current measurement, pulse measurement, harness fault finding and a charging demonstration | Practical assessment result, scored with the rubric |
Worksheets and instructor guide
One worksheet per module. Students open it on the web, print it or download the .docx. The instructor guide under each worksheet gives the class timing, expected results, discussion questions and notes for students with different backgrounds.
1Worksheet 1 Ohm's law, an LED circuit and wire resistance
Lab · About 6 h of class time · CLO1, CLO3
Objective: Confirm Ohm's law from measurements, size an LED current-limiting resistor and find the voltage drop in main power leads
Equipment
- Adjustable supply with a settable current limit
- Multimeter
- 100 Ω resistor with an adequate power rating
- LED and resistor from Example 1
- 1 m lengths of different wire gauges
- Breadboard and jumper leads
Safety
- Set the supply's current limit before connecting any circuit
- Do not touch power resistors or leads while passing 10 A; they get very hot
- Check the resistor's power rating before powering up
Steps
- Set the current limit and connect the 100 Ω resistor to the supply
- Vary voltage from 1 to 10 V and record current at each step
- Plot I against V; find the slope and compare with 1/R
- Size the LED resistor as in Example 1; build it and measure the actual current
- Pass 10 A through each 1 m wire and measure the voltage drop across it
- Compute each wire's resistance from the readings and compare with the lesson formula
Deliverables
- I-V table and graph with slope
- LED calculation and measured current
- Wire voltage-drop and resistance table against the formula
Checklist
- Table 1 has all 10 rows (1 to 10 V) with units, and the I-V graph has a straight line with its slope
- The LED resistor calculation converts 15 mA to 0.015 A before substituting and also shows the resistor's power
- Table 3 computes R = ρL/A with the area in m² and gives the percentage difference from the reading in every row
- You recorded that the current limit was set before each circuit was connected, and the limit used in each part
- Current was measured with the meter in series, and the meter jack used (mA or A) is stated
Instructor guide
Class timing
- Objectives, safety and how to set the supply's current limit30 min
- Measure I against V for the 100 Ω resistor and plot the graph90 min
- Calculate, build and measure the LED circuit60 min
- Pass 10 A through each wire and measure the drop90 min
- Compare with the formula and answer the questions60 min
- Wrap-up, discussion and hand-in checklist30 min
Expected results
- Table 1: 10, 20, ... up to 100 mA at 1 to 10 V (I = V/100). The graph is a straight line through the origin with slope 0.0100 A/V = 1/R. With a ±5% resistor accept slopes of 0.0095 to 0.0105 A/V (R of 95 to 105 Ω). R = V/I should be about the same in every row.
- Table 2 (Example 1: 5 V supply, LED drop 2.0 V, 15 mA): R = 3.0/0.015 = 200 Ω, resistor power 3.0 × 0.015 = 0.045 W, so 0.25 W is fine. The measured current depends on the LED's real drop: for 1.8 to 2.2 V expect about 14 to 16 mA.
- Table 3 (if the lab uses 1 m copper wires of 0.5, 1.0 and 2.08 mm² (14 AWG), ρ = 1.68 × 10⁻⁸ Ω·m): formula R of 33.6, 16.8 and 8.08 mΩ; drops at 10 A of about 336, 168 and 81 mV; heat of 3.36, 1.68 and 0.81 W. Readings are usually a little above the formula because the wire warms and the probe points may include part of a joint; accept about 10 to 20% difference.
- R = 1/slope; a slope of 0.0098 A/V gives about 102 Ω (2% off). Causes: resistor tolerance, meter accuracy and reading. A strong answer says a few percent still agrees with Ohm's law because the points still lie on a straight line.
- P = V²/R = 100/100 = 1.0 W. A 0.25 W resistor would overheat and burn; choose at least twice the calculated power, so 2 W or more.
- Current = (5 − V_LED)/200: a real drop of 1.8 V gives about 16 mA, 2.2 V about 14 mA. LED colours have different drops. A strong answer puts the measured drop into the formula and gets close to the meter reading.
- Doubling the area halves R and the drop (336 to 168 mV). With 0.5 mm² wire, 0.6 m at 30 A: R = 20.2 mΩ, drop about 0.60 V and heat about 18.1 W, against 0.15 V and 4.4 W for the 14 AWG leads of Example 3. A strong answer concludes that thin wire starves the motors of voltage and runs dangerously hot.
Discussion questions
- Why does a drop of only 0.15 V in the main leads still matter on a drone, once you think about heat and loose connectors?
- Between which two values should a fuse rating sit, and what happens if it is too low or too high?
Adapting to student background
- Upper secondary (M.6)
- Have them predict the graph and every current from the formula before wiring, and pair them with a peer who is quick at breadboarding and supply settings.
- Vocational certificate
- Give a fill-in table that converts mA to A and mm² to m² step by step, and let them check each row with a calculator before plotting.
- Diploma
- Extension: measure the drop across one battery connector pair at 10 A and compare it with the 1 m wire, to see whether the joint has more resistance than the wire.
2Worksheet 2 Series and parallel circuits, Kirchhoff's laws and the voltage divider
Lab · About 6 h of class time · CLO1, CLO3
Objective: Build circuits correctly from schematics, check KCL and KVL from readings, design a battery-sensing divider and check cell balance
Equipment
- Adjustable supply
- Multimeter
- Assorted resistors
- Breadboard and jumper leads
- Cell checker
- Sample lithium battery
Safety
- Use a supply instead of a battery when testing the divider, with the current limit set
- Never short battery terminals; check polarity before plugging in the cell checker
- If a battery is swollen, hot or smells, stop and tell the lecturer
Steps
- Draw schematics of series and parallel circuits with three resistors
- Build them from the schematics; measure voltage and current everywhere
- Check KCL at nodes and KVL around loops from the readings
- Design a 4S battery divider giving at most 3.3 V and compute the scaling factor
- Build it on a breadboard, feed it from the supply and compare with the calculation
- Measure each cell of the sample battery and find the largest difference
Deliverables
- Schematics and measurement tables
- KCL and KVL check
- Divider design with measurements
- Cell-voltage table and battery condition
Checklist
- The series and parallel schematics use standard symbols and show resistor values and measuring points
- Table 1 shows the KVL check around the series loop and the KCL check at the parallel junction as numbers with units
- The divider design shows V_out at 16.8 V is at most 3.3 V and computes the multiplier (R1 + R2)/R2
- The divider was tested from a current-limited supply, not a battery, and polarity was checked before plugging in the cell checker
Instructor guide
Class timing
- Objectives, battery safety and a schematic-reading review30 min
- Draw schematics, build series and parallel circuits and measure every point120 min
- Check KCL and KVL from the readings30 min
- Design, build and measure the voltage divider90 min
- Measure the sample battery's cells45 min
- Questions, wrap-up and hand-in checklist45 min
Expected results
- Table 1 (if the lab uses 1 kΩ, 2 kΩ and 3 kΩ on 12 V): series total 6 kΩ, 2.0 mA, drops of 2.0, 4.0 and 6.0 V, KVL 12 − 2 − 4 − 6 = 0. Parallel branches 12.0, 6.0 and 4.0 mA, total 22.0 mA, combined 545 Ω; the largest power is 0.144 W in 1 kΩ, so 0.25 W resistors are fine. Readings may be about 5% off the calculation because of resistor tolerance, but KCL and KVL should balance to within a few percent.
- Table 2 (if R1 = 47 kΩ and R2 = 10 kΩ as in practice question 5): the ratio must be at most 3.3/16.8 = 0.196; this divider gives 0.175 with multiplier 57/10 = 5.70. At 12.0, 14.8 and 16.8 V, V_out is 2.11, 2.60 and 2.95 V. Accept any other design whose V_out at 16.8 V is at most 3.3 V (for example 100 kΩ with 13 kΩ gives 1.93 V).
- Table 3 (depends on the real pack; for a 4S pack in storage, for example 3.82, 3.80, 3.81 and 3.79 V): total 15.22 V, largest difference 0.03 V, and the pack is at storage level (about 3.8 V per cell). If one cell is clearly lower than the others, it needs balance charging and the lecturer should be told.
- 12.0 + 6.0 + 4.0 = 22.0 mA should match the total within a few percent. Small differences come from meter accuracy, rounding and the small resistance of the meter in series. A strong answer says charge does not disappear, so the difference is in the measurement, not the law.
- 12 V/22 mA ≈ 545 Ω, which is less than 1 kΩ, because each parallel branch adds a path for current: at the same voltage more branches mean more total current, so lower combined resistance.
- With 47 kΩ and 10 kΩ: 16.8 × 10/57 ≈ 2.95 V, which is safe. Swapped: 16.8 × 47/57 ≈ 13.85 V, far above 3.3 V, which can destroy the ADC pin. A strong answer says always check V_out from a supply before connecting a real flight controller.
- The cells are in series, so by KVL the pack voltage equals the sum of the cells (for example 15.22 V) within meter accuracy. With a ±(0.5% + 2 digits) meter the uncertainty at 3.80 V is about ±0.04 V, so a 0.03 V difference is not enough to call the pack unbalanced. A strong answer links the measured difference to the instrument's accuracy.
Discussion questions
- If ArduPilot's voltage-multiplier parameter is set wrongly, which way could the low-battery warning go wrong, and why is that dangerous?
- Why must the main leads of a distribution board feeding four ESCs in parallel carry more current than each ESC lead?
- In a 4S pack, what happens to a cell that sits lower than the others when the pack is used until nearly empty?
Adapting to student background
- Upper secondary (M.6)
- Have them write the KVL and KCL equations before measuring and then test them with readings; add practice matching the schematic to the real breadboard with a hands-on peer.
- Vocational certificate
- Start with building and measuring, then use a fill-in table to add up voltages and currents; for the divider give them 47 kΩ and 10 kΩ and let them confirm it by measurement.
- Diploma
- Extension: design a 6S divider giving at most 3.3 V from the resistors in the lab, and compute the multiplier that would be set in the flight controller.
3Worksheet 3 AC signals, RC circuits and filters
Lab · About 6 h of class time · CLO1, CLO3
Objective: Read AC signals on an oscilloscope, measure an RC time constant and find the cut-off of a low-pass filter
Equipment
- Oscilloscope
- Function generator
- Multimeter
- 10 kΩ resistor and 100 µF capacitor
- Breadboard and jumper leads
- 1 kΩ resistor and 100 nF capacitor for the filter (Example 3)
Safety
- Electrolytic capacitors are polarised and can burst if reversed; check polarity before powering
- Use a capacitor rated above the working voltage
- Use only low-voltage signals from the generator; do not measure mains
Steps
- Apply a sine wave; read peak, period and frequency on the oscilloscope
- Measure RMS with the multimeter and compare with the peak
- Build the RC circuit with 10 kΩ and 100 µF; apply a slow square wave
- Measure the time to 63% and compare with τ = RC = 1 s
- Build an RC filter with 1 kΩ and 100 nF as in Example 3; apply sine waves of several frequencies and record output amplitude
- Find where the amplitude falls to about 70.7% and compare with the formula
Deliverables
- Table of peak, period, frequency and RMS
- Charging capture and measured τ
- Amplitude-frequency plot and cut-off frequency
Checklist
- Table 1 records the scope settings (volts/div and time/div) and every reading with its unit
- Table 2 computes v_C = V(1 − e^(−t/RC)) in every row and states the time to 63% against τ = 1 s
- 100 µF and 100 nF are converted to farads before computing τ and f_c
- The electrolytic capacitor's polarity and voltage rating were checked and recorded before powering
- The amplitude-frequency graph marks the measured f_c against the formula value, with the difference explained
Instructor guide
Class timing
- Objectives, safety and an oscilloscope set-up demonstration45 min
- Read the sine wave on the scope and measure RMS75 min
- Build the RC circuit and measure charging75 min
- Build the filter and measure amplitude at several frequencies90 min
- Plot, compare with the formulas and answer the questions45 min
- Wrap-up, discussion and hand-in checklist30 min
Expected results
- Table 1 (if the sine is set to 5 V peak (10 Vpp) at 100 Hz): period 10.0 ms, frequency 100 Hz, V_rms = 5/√2 ≈ 3.54 V. The meter should read close to 3.54 V; accept about ±5%. If the meter reads very differently at higher frequencies, check the AC frequency range in the meter's manual.
- Table 2 (0 to 5 V square wave, τ = 10 kΩ × 100 µF = 1.00 s): at t = 0.5, 1, 2, 3 and 5 s expect 1.97, 3.16, 4.32, 4.75 and 4.97 V (39.3, 63.2, 86.5, 95.0 and 99.3%). The time to 63% (3.16 V) should be about 1 s; the real capacitance may differ from the marking, so accept 0.8 to 1.2 s.
- Table 3 (f_c = 1/(2π × 1000 × 100 × 10⁻⁹) ≈ 1592 Hz, 2 Vpp input): output/input at 100, 500, 1000, 1592, 3000, 10000 and 20000 Hz of about 0.998, 0.954, 0.847, 0.707, 0.469, 0.157 and 0.079 (output about 2.00, 1.91, 1.69, 1.41, 0.94, 0.31 and 0.16 Vpp). The calculated column uses 1/√(1 + (f/f_c)²); accept a measured f_c of about 1.4 to 1.8 kHz.
- 5/3.54 ≈ 1.41 = √2; measured ratios should be about 1.35 to 1.48. Mains 230 V is an RMS value, so its peak is 230 × √2 ≈ 325 V. A strong answer says equipment on mains must withstand the peak, not just the label value.
- C = τ/R: 0.8 s gives 80 µF and 1.2 s gives 120 µF (20% off). A strong answer says electrolytic capacitors can differ quite a lot from their marking, and reading time on the screen also has error.
- It should be near 1.6 kHz. At 20 kHz the output falls to about 0.079, or 8%, of the input. A strong answer says slow signals such as battery voltage pass almost unchanged while switching noise is strongly reduced.
- Half a period at 1 Hz is 0.5 s, giving only 1 − e^(−0.5) ≈ 39.3%. The high part must last at least 5τ = 5 s, so a period of at least 10 s, or at most 0.1 Hz, to charge above 99%.
Discussion questions
- Why do many ESC makers recommend a low-ESR capacitor close to the ESC's power terminals?
- If an ESC cuts 10 A in 1 µs through a lead with 50 µH of inductance, how large is the spike, and how should battery leads be designed?
Adapting to student background
- Upper secondary (M.6)
- Have them sketch the expected v_C curve from the formula before measuring, and let them time and read the scope while a hands-on peer helps with wiring.
- Vocational certificate
- Give a prepared table of e^(−t/RC) values instead of computing exponentials, and practise setting volts/div and time/div step by step before reading values.
- Diploma
- Extension: view the supply voltage at a small-motor circuit with and without a capacitor across its terminals and compare the noise you see.
4Worksheet 4 Diodes, PWM and ESC signals
Lab · About 6 h of class time · CLO2, CLO3
Objective: Measure diode behaviour, drive a motor with PWM through a MOSFET and read ESC control signals
Equipment
- Multimeter with diode mode
- Silicon and Schottky diodes and LEDs of several colours
- Microcontroller, MOSFET and small DC motor
- Oscilloscope
- Servo tester, ESC and motor with propellers removed
- Smoke stopper
Safety
- Always remove propellers when testing ESCs on the bench
- Use a smoke stopper at first power-up
- MOSFETs and motors can get hot; do not touch them in operation
Steps
- Measure the forward voltage of each diode type in diode mode
- Write a program producing PWM at several duty cycles
- Drive the MOSFET and motor; measure duty cycle on the scope and average voltage on the multimeter
- Compare the average voltage with duty cycle times supply voltage
- Connect the servo tester to the ESC through a smoke stopper
- View the 1000–2000 µs pulses on the scope; record pulse width and frequency
Deliverables
- Forward-voltage table
- Duty cycle, average voltage and calculation table
- ESC pulse captures with readings
Checklist
- Table 1 includes silicon, Schottky and at least two LED colours, each with V_F and its unit
- Table 2 computes D = t_on/T from the scope readings and compares V_avg with D × V_in in every row
- Table 3 converts every pulse width to throttle with (t − 1000 µs)/1000 µs
- Propellers were removed and the smoke stopper connected before powering the ESC, confirmed by the supervisor's signature
- Scope probe and ground were connected to the right points, with time/div set to show at least one full period
Instructor guide
Class timing
- Objectives and safety; remove propellers, fit the smoke stopper30 min
- Measure V_F of the diodes and LEDs45 min
- Program PWM and wire the MOSFET and motor90 min
- Measure duty cycle and average voltage60 min
- Connect the servo tester to the ESC and read the pulses75 min
- Questions, wrap-up and hand-in checklist60 min
Expected results
- Table 1: silicon about 0.7 V, Schottky about 0.3 to 0.4 V, LEDs about 1.8 to 3.3 V depending on colour. Diode-mode readings can be a little below the lesson values because the meter uses a small test current. Heat at 30 A is V_F × 30, for example 21 W at 0.7 V and 12 W at 0.4 V.
- Table 2 (if the motor supply is 12.0 V and PWM is 1 kHz, period 1000 µs): D of 25, 50, 75 and 100% gives t_on of 250, 500, 750 and 1000 µs and D × V_in = 3.0, 6.0, 9.0 and 12.0 V. Meter readings should be within about 10% of the calculation.
- Table 3: pulse widths within 1000 to 2000 µs, for example 1000, 1350, 1500 and 2000 µs for 0, 35, 50 and 100% throttle. Frequency is in the tens to hundreds of hertz depending on the tester, for example 50 Hz with a 20 ms period; changing pulse width does not change the period.
- Silicon 0.7 × 30 = 21 W, Schottky 0.4 × 30 = 12 W; both are far too much heat for a small part. High-current circuits use a MOSFET acting as an ideal diode, or polarised connectors that cannot be reversed. A strong answer puts the group's own readings into P_D = V_F I.
- They should agree nearly everywhere. If every reading is well below the calculation, the microcontroller's gate voltage may be too low, so the MOSFET only partly turns on with high R_DS(on) (a common mistake in the lesson); check whether the MOSFET is hot. A strong answer separates reading error from a circuit problem.
- The resistor must drop 12 − 6 = 6 V; at 0.5 A it wastes 6 × 0.5 = 3.0 W as heat, while a 5 mΩ MOSFET at 0.5 A loses only about 1.25 mW (ignoring switching losses). A strong answer says a switch that is fully on or fully off wastes almost nothing, which is why PWM is efficient.
- Use (t − 1000)/1000; for example 1350 µs is 35%. A servo-PWM ESC must learn which pulse widths mean zero and full throttle, which can differ between devices, so it needs calibration. DShot sends speed as a digital number with a checksum, so it needs no calibration and resists noise better.
Discussion questions
- Why do high-voltage drones use switching BECs instead of linear ones, and what must be watched for with video and radio systems?
- If 100 Hz frame vibration is logged at 150 samples per second, what will the data show, and how should it be fixed?
- What happens if a 5 V signal is connected straight to a 3.3 V microcontroller pin, and how is it prevented?
Adapting to student background
- Upper secondary (M.6)
- Provide working PWM sample code for them to change the duty cycle, focus on predicting V_avg before measuring, and add supervised practice wiring the MOSFET and motor.
- Vocational certificate
- Use a fill-in table for D = t_on/T and (t − 1000)/1000 with the first row worked, and let them explain by watching the real motor speed alongside the screen.
- Diploma
- Extension: measure the drain-source voltage of the MOSFET while it is on, then compute the real R_DS(on) and conduction loss from the measured current.
5Worksheet 5 Using instruments and electrical safety (practical assessment)
Lab · About 6 h of class time · CLO3
Objective: Show correct and safe use of the multimeter and oscilloscope, find a circuit fault and charge a lithium battery by procedure
Equipment
- Multimeter
- Oscilloscope
- Lithium battery with balance lead
- LED circuit and small-motor circuit
- Servo tester
- Sample harness with a fault set by the lecturer
- Balance charger, fire-resistant bag or box and charging checklist
Safety
- Move the lead back to the V jack after every current measurement
- Beware the scope ground; connect the probe ground only to circuit ground
- Charge in a fire-resistant bag or box, always attended, and never charge a swollen battery
Steps
- Measure each cell through the balance lead, record it and state the battery's condition
- Measure current in the LED and small-motor circuits, then return the lead to the V jack
- Measure the pulse width and frequency of the servo tester's signal
- Check continuity in the harness and find the fault set by the lecturer
- Demonstrate battery charging using the checklist
Deliverables
- Record sheet for all five stations
- Fault location and how it was found
- Charging checklist signed by the examiner
Checklist
- Table 1 has every cell voltage, the total, the largest difference and the meter uncertainty calculated from its specification
- Table 2 states that current was measured in series and ticks that the lead went back to the V jack after every current reading
- Pulse width and frequency are computed as divisions times time/div, with the time/div used recorded
- The fault record gives the location and the check order: visual first, measurements with power off, then voltages with power on
- Every item on the charging checklist is done and signed by the examiner
Instructor guide
Class timing
- Assessment briefing, criteria and safety; remove rings, watches and metal jewellery30 min
- Stations 1 and 2: cell voltages and current measurement90 min
- Station 3: pulse measurement on the oscilloscope60 min
- Station 4: harness fault finding75 min
- Station 5: charging demonstration with the checklist75 min
- Questions, review and feedback on results30 min
Expected results
- Table 1 (depends on the real pack): full is 4.20 V per cell (16.8 V for 4S), storage about 3.8 V (15.2 V for 4S). With a ±(0.5% + 2 digits) meter on two decimals the uncertainty is about ±0.041 V at 4.20 V and ±0.039 V at 3.80 V. The condition must follow the readings, such as full, storage or low, and must note any swelling or heat.
- Table 2: the LED circuit from Worksheet 1 reads about 14 to 16 mA on the mA jack; the motor current depends on the motor, using the A jack if it exceeds the mA fuse rating. Every row must tick that the lead went back to V. The servo tester signal is within 1000 to 2000 µs. Example reading: at 0.5 ms/div a 3-division pulse is 1.5 ms (1500 µs) and a 5-division period is 2.5 ms, so 400 Hz.
- Fault record: the location matches the fault the lecturer set (for example a broken wire, loose connector or short), with the check order: visual inspection for loose wires, burn marks and poor joints; then power off and check continuity and the resistance between positive and negative (near zero is a short, so do not power it); only then power on and compare voltages at key points with calculated values.
- The uncertainty at 3.80 V is 0.005 × 3.80 + 2 × 0.01 ≈ 0.039 V, about ±0.04 V. A 0.03 V difference lies inside it, so you cannot conclude the pack is unbalanced; a more accurate instrument is needed, or a check of whether the difference grows with use.
- In current mode the meter has almost zero resistance, so across a battery it is a short circuit: a very large current flows, the meter's fuse blows and in severe cases there is an arc flash. A strong answer links this to Ohm's law, I = V/R with R near zero.
- The right order is visual inspection, then measurements with power off, then voltages with power on. Measuring resistance in a live circuit gives wrong readings and can damage the meter, and checking for shorts before powering stops the circuit from burning.
- 1C for 5000 mAh is 5.0 A (not above the maker's rating). The CV stage holds 4.2 V per cell, or 16.8 V for the pack. Before charging, set the correct chemistry and cell count, connect the balance lead, check the pack is not swollen or deformed, place it in a fire-resistant bag or box on a non-flammable surface, and stay with it throughout.
Discussion questions
- To measure at a charger plugged into mains, what minimum CAT rating must the meter and leads have, and why?
- Why can a low-voltage drone battery still be dangerous even though electric shock is unlikely?
Adapting to student background
- Upper secondary (M.6)
- Before the assessment give one extra round of hands-on meter and scope practice on real circuits, and have them explain the reason for each charging-checklist item aloud.
- Vocational certificate
- Provide step cards for each station (select mode, select jack, connect, read, move lead back) and a fill-in table with a worked example for the uncertainty calculation.
- Diploma
- Extension: find a second harness with two faults, and write the check sequence as a flow chart for junior students to use.
Scoring rubric
For worksheets and the mini-project. Each criterion scores level (1–4) ÷ 4 × weight.
| Criterion | Weight | Excellent (4) | Good (3) | Fair (2) | Needs work (1) |
|---|---|---|---|---|---|
| Accuracy of circuit calculations | 25% | Ohm's law, KCL, KVL and formulas all correct with units and every step shown | Nearly all correct; minor unit or rounding slips | Some errors or key steps missing | Many errors or no method shown |
| Circuit building and use of instruments | 30% | Builds circuits correctly from schematics, chooses meter modes and jacks correctly, sets up the oscilloscope unaided | Mostly correct with a little help | Frequent wiring or mode errors; needs much help | Cannot use the instruments |
| Safe working practice | 25% | Always sets current limits, removes propellers, checks polarity and follows the battery checklist without reminders | Complete with occasional reminders | Skips some safety steps | Unsafe practice; work had to be stopped |
| Recording results and comparing with theory | 20% | Complete tables and graphs; measurements compared with calculations and differences explained correctly | Complete with partial explanation of differences | Some tables missing or no comparison with theory | Records too incomplete to conclude |
Assessment map: CLOs and how they are assessed Draft