UAT 208 Digital Drafting and Prototyping Technology
Worksheet 3 Thickness and arm deflection (L04)
Objective
Calculate, simulate with FEM and physically test the effect of thickness and print orientation on arm deflection
Equipment and materials
- FreeCAD FEM
- Python and the module 3 example code
- 3D printer and PLA
- Weights, clamp fixture and ruler or dial gauge
Safety
- Hot nozzle and bed: do not touch while printing
- Clamp the part firmly before hanging weights; never stand under them
- Wear safety glasses when a part may break
Steps
- Model a simple arm with clear material, load and support
- Run a static FreeCAD FEM analysis; compare deflection with Example 2
- Change thickness only; record deflection and mass
- Refine the mesh two levels and note how much the result changes
- Print the arm in two orientations, load with weights and compare measured deflection with calculation
Record of results
| Thickness t (mm) | Hand-calculated deflection (mm) | FEM deflection (mm) | Difference (%) | Mass (g) |
|---|---|---|---|---|
| Mesh level | Number of elements | Maximum deflection (mm) | Change from previous level (%) |
|---|---|---|---|
| Print orientation | Load (N) | Measured deflection (mm) | Calculated deflection (mm) | Notes (cracks, layer failure) |
|---|---|---|---|---|
Questions
From Table 1, by what factor does deflection fall when thickness grows from 3 to 6 mm? Does it match the formula (proportional to 1/t³), and by what factor does the mass grow?
From Table 2, at which mesh level would you stop refining, and why? If the FEM result differs a lot from the hand calculation, what should you check first?
In Table 3, how far is the measured deflection from the calculated one? Give at least two reasons why a real printed part does not match the formula.
For a 4 mm plate with 10 N at the tip, what is the stress at the root, and how do the safety factors differ when layers run along the plate and across it? Which orientation would you print the real arm in?
Check before you hand in
What to hand in
- Hand calculation and FEM results
- Thickness, deflection and mass table
- Mesh study
- Measured results for two orientations with reasons for differences