UAT 303 UAS Inspection and Maintenance
Worksheet 3 Diagnosis from a real log
Objective
Diagnose faults with vibration spectra and redundant-sensor comparison, then confirm by flying again
Equipment and materials
- Training drone that records logs
- ArduPilot WebTools (FilterReview)
- Small pieces of tape
- Computer with Python and the module 3 example code
- Thrust stand with a shield, or a thrust-stand data set prepared by the instructor
Safety
- Fly within CAAT conditions in visual line of sight; keep people clear
- Add tape only under supervision, with the battery removed
- Land at once if vibration becomes severe
- Run the thrust stand from behind a shield with current and speed cut-offs set; stay out of the propeller plane
Steps
- Download a hover log and view the spectrum in FilterReview
- Add tape near one blade tip under supervision and hover again
- Compare the spectra with Example 1
- Test a suspect and a new motor on the thrust stand (or the instructor's data set if no stand is available) and compare with Example 3
- Extract every IMU at rest and compare with Example 2
- Write a one-page diagnosis separating evidence, conclusion and confirmation
- Remove the tape and fly to confirm the spectrum returns to normal
Record of results
| Flight | Hover rpm and source | 1× and blade-pass frequency (Hz) | 1× peak size | Blade-pass peak size | 1× to blade-pass ratio |
|---|---|---|---|---|---|
| Sample | IMU0 (deg/s) | IMU1 (deg/s) | IMU2 (deg/s) | Median (deg/s) | Outlier beyond 1.0 deg/s |
|---|---|---|---|---|---|
| Throttle step or no load | Thrust (g) reference/suspect | Current (A) reference/suspect | g/W reference/suspect | Change (%) | Meets criterion? |
|---|---|---|---|---|---|
Questions
In your group's spectra, which peak changed when the tape was added, and why does this pattern point to imbalance in a rotating part rather than a loose damping mount?
The suspect motor in Example 3 loses only a few percent of thrust. Why must it be judged by thrust per watt rather than thrust alone, and what cause does the higher no-load current point to?
If two motors turn at 5,000 and 5,060 rpm, can a 3 s log separate their 1× peaks? What about a 1 s log?
If a drone has only two IMUs and they differ by 1.6 deg/s at rest, what can and cannot be concluded, and what should be done next?
Check before you hand in
What to hand in
- Spectra before, with and after the tape
- IMU comparison table
- One-page diagnosis
- Thrust-stand results table and motor verdict