UAT 303 UAS Inspection and Maintenance

Worksheet 3 Diagnosis from a real log

Lab 12 hAssesses CLO2

Objective

Diagnose faults with vibration spectra and redundant-sensor comparison, then confirm by flying again

Equipment and materials

  • Training drone that records logs
  • ArduPilot WebTools (FilterReview)
  • Small pieces of tape
  • Computer with Python and the module 3 example code
  • Thrust stand with a shield, or a thrust-stand data set prepared by the instructor

Safety

  • Fly within CAAT conditions in visual line of sight; keep people clear
  • Add tape only under supervision, with the battery removed
  • Land at once if vibration becomes severe
  • Run the thrust stand from behind a shield with current and speed cut-offs set; stay out of the propeller plane

Steps

  1. Download a hover log and view the spectrum in FilterReview
  2. Add tape near one blade tip under supervision and hover again
  3. Compare the spectra with Example 1
  4. Test a suspect and a new motor on the thrust stand (or the instructor's data set if no stand is available) and compare with Example 3
  5. Extract every IMU at rest and compare with Example 2
  6. Write a one-page diagnosis separating evidence, conclusion and confirmation
  7. Remove the tape and fly to confirm the spectrum returns to normal

Record of results

Table 1 Spectrum peaks before, with and after the tape
FlightHover rpm and source1× and blade-pass frequency (Hz)1× peak sizeBlade-pass peak size1× to blade-pass ratio
Table 2 IMU comparison at rest
SampleIMU0 (deg/s)IMU1 (deg/s)IMU2 (deg/s)Median (deg/s)Outlier beyond 1.0 deg/s
Table 3 Thrust-stand results, reference against suspect motor
Throttle step or no loadThrust (g) reference/suspectCurrent (A) reference/suspectg/W reference/suspectChange (%)Meets criterion?

Questions

  1. In your group's spectra, which peak changed when the tape was added, and why does this pattern point to imbalance in a rotating part rather than a loose damping mount?

  2. The suspect motor in Example 3 loses only a few percent of thrust. Why must it be judged by thrust per watt rather than thrust alone, and what cause does the higher no-load current point to?

  3. If two motors turn at 5,000 and 5,060 rpm, can a 3 s log separate their 1× peaks? What about a 1 s log?

  4. If a drone has only two IMUs and they differ by 1.6 deg/s at rest, what can and cannot be concluded, and what should be done next?

Check before you hand in

What to hand in

  • Spectra before, with and after the tape
  • IMU comparison table
  • One-page diagnosis
  • Thrust-stand results table and motor verdict

CLO2 Diagnose faults from symptoms and flight logs. (CLOs are a web-team draft; the course owner sets the final ones.)

Instructors: answers and teaching notes for this worksheet are in the teaching pack