UAT 321 Unmanned Aircraft Systems Installation, Integration, Inspection and Maintenance Laboratory

Worksheet 2 Calibration and first test flight

Lab 12 hAssesses CLO1, CLO2

Objective

Calibrate in sequence, confirm motor order and direction, tune the battery monitor, set failsafes and check vibration from a test flight

Equipment and materials

  • Training drone from worksheet 1
  • Mission Planner or QGroundControl
  • Multimeter
  • Charger that shows charge added
  • Enclosed flying area or cage
  • Python and the module 2 example code

Safety

  • Propellers off during calibration and motor tests
  • Test-fly under lecturer supervision in an enclosed area, within CAAT conditions and visual line of sight
  • Set failsafes before the first flight
  • Charge batteries in a fire-safe container, never unattended

Steps

  1. Calibrate in the Figure 1 order; record firmware version and a screenshot of each step
  2. Propellers off, test each motor; confirm order and direction against the frame's motor map
  3. Measure voltage with a multimeter, adjust the voltage multiplier and set 6-cell failsafe thresholds with reasons
  4. Hover for two minutes in the enclosed area; download the log and analyse vibration with Example 2
  5. Compare logged capacity used with the charger's recharge; decide whether to adjust the current multiplier

Record of results

Table 1 Calibration log in the Figure 1 order
StepItem calibrated or setResult or valueScreenshot no.Checker
Table 2 Motor order and direction test (propellers off)
Motor (frame map)Position on frameExpected directionObserved directionPass or fix made
Table 3 Battery monitor, failsafe and vibration
QuantitySystem or log valueReference (multimeter or charger)New setting or resultReason

Questions

  1. Before adjustment, did the system read voltage high or low, and if left uncorrected would the voltage failsafe act earlier or later than it should? How does an under-read current affect the remaining-charge failsafe?

  2. Explain the low and critical failsafe thresholds your group set for a 6-cell battery. Why is the 10.5 V default unusable, and why wait for the voltage to stay low before acting?

  3. Which ArduPilot range does your logged vibration fall in, and did clipping increase? If any axis is above 30 m/s², what would you check next, in order?

  4. From the comparison of logged charge used with the charger's recharge, would your group adjust the current multiplier from this one flight? Why?

Check before you hand in

What to hand in

  • Screenshots of every calibration step
  • Motor order and direction results
  • Multipliers and failsafe thresholds with reasons
  • Vibration plot and current multiplier conclusion

CLO1 Install, configure and calibrate UAS subsystems. CLO2 Diagnose and maintain from operational data. (CLOs are a web-team draft; the course owner sets the final ones.)

Instructors: answers and teaching notes for this worksheet are in the teaching pack