UAT 361 Unmanned Aircraft Systems Technology for Surveying, Mapping and Inspection

Worksheet 4 Wall and solar roof inspection

Lab 12 hAssesses CLO1, CLO2

Objective

Plan an inspection from the smallest damage to see, capture wall and thermal solar images, and produce a confirmed anomaly list

Equipment and materials

  • Drone with RGB and thermal cameras
  • Irradiance meter, air thermometer and anemometer
  • Python and module 4 example code
  • Lab notebook

Safety

  • Fly within CAAT conditions in visual line of sight under supervision; keep the planned stand-off from walls and roofs
  • Do not climb roofs or touch panels and cables; ground checks only from safe positions
  • Guard against sun and heat outdoors
  • Inspect batteries before flight; keep them in fire-safe bags or boxes

Steps

  1. Agree with the user the smallest damage to see and the pixels needed across it
  2. Apply Example 1 to the real camera, choose stand-off and lens, plan safe wall lanes and fly them
  3. Take thermal images of the panels, recording irradiance, air temperature, wind, emissivity and T_refl
  4. Fix hot-spot criteria before seeing results; build the grid and run Example 3
  5. Confirm each finding with colour images and a ground check
  6. Write the anomaly list with location, images and action level

Record of results

Table 1 Stand-off distance and lens
Lens f (mm)Agreed crack size (mm) / pixelsRequired GSD (mm)Maximum distance D (m)Wall width per image (m)Distance chosen and reason
Table 2 Thermal imaging condition log
TimeIrradiance (W/m²)Air temperature (°C)Wind (km/h)Emissivity / T_refl setImage numbers
Table 3 Anomaly list
ID and location on the structureType (crack / hot spot)Size or ΔT from median (K)Confirmed by colour image and ground checkAction level

Questions

  1. Why did your group choose the distance and lens in Table 1? With the wide-angle lens instead, how far from the wall would you have to fly, and what are the risks?

  2. If the irradiance during imaging was below 600 W/m², how far can your hot-spot results be trusted, and what should you do?

  3. If emissivity is set higher than the true value, what happens to the temperature read? Why does your group use the difference from the median instead of absolute temperatures?

  4. Why must hot-spot criteria be agreed before seeing the results, and how does your group tell that a hot spot is really bird droppings or shade?

  5. From today's work, how should your report state the limits of drone inspection compared with contact inspection?

Check before you hand in

What to hand in

  • Stand-off and lane calculations
  • Wall and thermal image sets with condition log
  • Hot-spot results against pre-agreed criteria
  • Anomaly list

CLO1 Plan and conduct survey, mapping and inspection. CLO2 Process outputs and assess accuracy. (CLOs are a web-team draft; the course owner sets the final ones.)

Instructors: answers and teaching notes for this worksheet are in the teaching pack