UAT 365 Unmanned Aircraft Systems Technology for Smart Agriculture and Remote Sensing
Worksheet 2 Calibrating multispectral images
Objective
Convert DN to reflectance with reference panels, compare the effect on NDVI and check the effects of changing light and band alignment
Equipment and materials
- Computer with the imageprocessing package (needs Git LFS) and sample images
- Multispectral camera with DLS and reference panel (if available)
- Lab survey drone (if available)
- Python and the module 2 example code
Safety
- Fly within CAAT conditions in visual line of sight under supervision
- Inspect batteries before flight and do not touch the reference panel surface
Steps
- Install the imageprocessing package per the project guide and open the sample images
- Locate the panel, compute mean DN and calibrate red and NIR with Example 1
- Compare NDVI from raw DN and from reflectance; record the difference
- Compare images before and after band alignment and inspect misaligned edges
- If a camera is available, shoot the panel before and after a real flight and log time, sky and DLS in the notebook
Record of results
| Band | Mean DN, dark panel (5%) | Mean DN, bright panel (50%) | Gain a (DN per unit reflectance) | Offset b (DN) |
|---|---|---|---|---|
| Sample point | Red reflectance | NIR reflectance | NDVI from DN | NDVI from reflectance | Difference |
|---|---|---|---|---|---|
| Time | Sky | Panel shot (before/after flight) | DLS red | DLS NIR | Notes (shadow, passing cloud, battery) |
|---|---|---|---|---|---|
Questions
From Table 2, how much does NDVI from DN differ from NDVI from reflectance, and why can NDVI from DN not be compared with published thresholds or across weeks?
If cloud passed during the flight as logged in Table 3, what happens to reflectance and NDVI of those images without DLS correction? Explain with Example 2.
In the image before band alignment, where are the index values wrong, and why?
Why must calibration be done band by band rather than with one line for all bands? Answer using the gain and offset in Table 1.
Check before you hand in
What to hand in
- Calibration coefficients per band
- NDVI from DN versus reflectance table
- Before-and-after alignment images
- Flight and light log in the notebook