Module 1/15 · Weeks 1 · 9 h

Inspection methodology and planning

UAT 453 UAS for Infrastructure, Energy and Utility Inspection

About 90 minDraft, awaiting reviewLast updated 24 October 2026

Lesson

By the end of this module you will be able to

  1. Explain the role of drones in building and infrastructure inspection, and what they cannot replace
  2. Classify common defects in concrete structures
  3. Define the smallest defect to be seen, then compute GSD, stand-off distance and lens choice
  4. Plan inspection at two levels: the whole wall first, then detail at selected spots
  5. Plan inspection of towers and tall structures, including what to check, the flight pattern, stand-off and specific hazards

Prerequisites: UAT 451 Aerial Photography and Photogrammetry

Why this matters

Traditional inspection of tall walls or bridge soffits needs scaffolding, cherry pickers or rope access, takes days, costs a lot and puts people at height. Drones capture images much faster and reduce risk to people, but images that are not detailed enough or incomplete lead to “inspected” when the real damage could not be seen. This module starts from what must be seen, then plans the flight.

Modules 1 to 5 of the course follow one fictional case through all of them: the university’s facilities department asks for an inspection of an eight-storey teaching building wall, 60 m wide and 30 m high, and a concrete bridge over a canal on campus. The team uses a 4/3-inch camera (17.3 mm wide, 5,280 × 3,956 pixels) with interchangeable lenses, plus a thermal camera. All figures are fictional. The Python code can be downloaded from /downloads/uat-453/.

Drones support inspectors, not replace them

Inspections range from routine to in-depth to special inspections after events. The US National Bridge Inspection Standards (NBIS, 2022) accept technologies such as drones to supplement the work of qualified inspectors, but tasks requiring contact, such as sounding for hollow concrete, measuring steel thickness or taking core samples, still need people. The engineer-inspector judges the structure’s condition; the drone pilot collects data good enough for that judgement.

Common defects in concrete

TypeAppearance in imagesWhat to record
CrackThin dark line, straight or map-likeWidth, length, direction, location
SpallingPits or broken edges, sometimes exposing rebarArea, approximate depth, whether rebar is exposed
EfflorescenceWhite deposits running from cracksIndicates water passing through the structure
Rust stainingReddish-brown stainsIndicates corroding rebar or metal parts
DelaminationOften invisible in colour images; needs thermal imaging or soundingApproximate extent

From defect size to GSD and distance

Start by agreeing with the user the smallest defect that must be seen and how many pixels must span it. Research by Lee et al. (2026) found that cracks only about 3 pixels wide or less are measured with high uncertainty, but it set no fixed number, so the pixel count is a project agreement, not an international standard.

The stand-off formula is the same as flight height in mapping, with the wall replacing the ground.

Example 1 A 1 mm crack spanning 4 pixels

SW, IW = 17.3, 5280                        # sensor width (mm) and pixels across
CRACK_MM, PX_ACROSS = 1.0, 4               # smallest crack to see, and pixels across agreed by the team
gsd = CRACK_MM / PX_ACROSS                 # required GSD (mm per pixel)
for f in (12.3, 45.0):                     # wide-angle and telephoto lens (mm)
    d = gsd / 1000 * f * IW / SW           # stand-off D = GSD · f · Iw / Sw
    print(f"lens {f:>4} mm: stand-off {d:.2f} m, image width on wall {gsd * IW / 1000:.2f} m")
lens 12.3 mm: stand-off 0.94 m, image width on wall 1.32 m
lens 45.0 mm: stand-off 3.43 m, image width on wall 1.32 m

The required GSD is 0.25 mm. The 12.3 mm wide-angle lens would need to fly less than 1 m from the wall, too close to be safe. A 45 mm telephoto gives the same detail at about 3.4 m. Both cover a 1.32 m wide strip of wall per image, because the GSD and pixel count are the same; what differs is the safety distance (module 2).

Side view with a grey wall on the right. A pink drone with a 12.3 mm lens is 0.94 metres from the wall; a green drone with a 45 mm lens is 3.43 metres away. Double-headed arrows show each distance
Figure 1 Stand-off for a 0.25 mm GSD with two lenses

Planning inspection at two levels

Images detailed to a fraction of a millimetre cover very little area, so capturing the whole wall at the highest detail does not pay.

Example 2 Images for the whole wall at two resolutions

With 70% overlap both horizontally and vertically.

import math

WALL_W, WALL_H = 60.0, 30.0                # wall width × height (m)
IW, IH, OVER = 5280, 3956, 0.70            # image pixels and overlap in both directions
for gsd_mm in (2.0, 0.25):                 # whole-wall survey, then detail at selected spots
    w, h = gsd_mm / 1000 * IW, gsd_mm / 1000 * IH
    cols = math.ceil(WALL_W / (w * (1 - OVER))) + 1
    rows = math.ceil(WALL_H / (h * (1 - OVER))) + 1
    print(f"GSD {gsd_mm} mm: image {w:.2f} x {h:.2f} m, {cols} x {rows} = {cols * rows:,} images for the whole wall")
GSD 2.0 mm: image 10.56 x 7.91 m, 20 x 14 = 280 images for the whole wall
GSD 0.25 mm: image 1.32 x 0.99 m, 153 x 103 = 15,759 images for the whole wall

At a 2 mm GSD about 280 images cover the whole wall, showing cracks several millimetres wide, spalls, stains and spots needing detail. At 0.25 mm almost 16,000 images would be needed. A sensible plan therefore works at two levels: survey the whole wall at a coarse GSD, then capture detail only where anomalies were found or at known risk spots such as window corners, joints and areas with water stains.

A blue wall 60 by 30 metres divided into a coarse 20 by 14 grid for whole-wall images at a 2 mm GSD, with one pink box in the middle finely divided for detailed 0.25 mm images at a selected spot
Figure 2 Survey the whole wall, then detail selected zones

Planning inspection of towers and tall structures

Towers and tall structures, such as lattice power-transmission towers, telecom towers and monopoles, guyed masts, chimneys, water towers and high-rise buildings, differ from a wall in three ways: they are open frames seen from every side, much of the important detail is high up, and they carry equipment that is itself a hazard.

What to look at. For telecom towers, the industry standard ANSI/TIA-222 (revision I, effective 1 January 2024, is the latest) sets out a maintenance and condition assessment in Section 14. Its Annex J checklist covers the structure’s condition, finish (paint or galvanising), lighting, grounding, mounts, antennas and lines, other appurtenances such as platforms, guy wires, concrete foundations, alignment (twist and plumb) and earlier modifications. As described for revision H, the standard recommends an assessment every three years for guyed masts and every five years for self-supporting towers, after severe wind or ice storms, and more often in coastal or corrosive places (Kisting & Erichsen, 2017); the summary of revision I changes (Stekr et al., 2024) does not mention a change to these intervals, but check Section 14 of the revision the owner works to. A drone survey records most of these items visually. Rusted area can be graded on a percentage scale such as ASTM D610 (written for painted steel) if the owner agrees. Bolt tightness, guy tension and plumb still need people and instruments on site.

How to fly. First name the legs (A, B, C, D), the faces and the height sections, just as the wall was named by face, floor and column bay. Then fly each face in vertical columns from the base up with the camera perpendicular to the face, add a ring at antenna or cross-arm level with the camera tilted up to see the undersides of platforms and mounts, and a ring at the base for foundations and anchor bolts. A high-rise building is planned like the wall at two levels, flown in vertical strips.

Hazards specific to towers. Transmission towers carry live conductors: EGAT advises people and machines to stay at least 4 m from high-voltage lines, so work near them must be coordinated with the utility and planned so that a drift can never bring the drone close. Telecom towers carry transmitting antennas: agree with the network operator which antennas will be transmitting and follow the operator’s RF safety rules (Annex J itself does not cover RF protection). Guy wires are thin and invisible to obstacle sensors, steel members disturb the compass as module 2 explains, and wind at the top of a tall structure is usually stronger than at the take-off point, so stop criteria must refer to wind at working height.

Example 3 A 45 m self-supporting telecom tower

With the network operator’s consent, the facilities department also asks for an inspection of a 45 m lattice telecom tower on campus. Its faces narrow from 6 m at the base to 1.5 m at the top (assumed values). The owner wants items 5 mm across to span 4 pixels, using the 45 mm lens.

import math

SW, IW, IH, F = 17.3, 5280, 3956, 45.0     # case-study camera with the 45 mm lens
ITEM_MM, PX = 5.0, 4                       # smallest item to see and pixels across it (assumed agreement)
HEIGHT, BASE_W, TOP_W = 45.0, 6.0, 1.5     # tower height and face width at base and top (m), assumed
STANDOFF, OVERLAP = 12.0, 0.6              # chosen distance from the tower face (m), vertical overlap

d_max = ITEM_MM / PX / 1000 * F * IW / SW  # farthest distance that still gives the required GSD
gsd = STANDOFF * SW / (F * IW) * 1000      # GSD at the chosen distance (mm)
w, h = gsd * IW / 1000, gsd * IH / 1000    # image footprint on the tower face (m)
step = h * (1 - OVERLAP)
rows = math.ceil(HEIGHT / step) + 1
per_face = 0
for k in range(rows):
    z = min(k * step, HEIGHT)
    face_w = BASE_W + (TOP_W - BASE_W) * z / HEIGHT
    per_face += math.ceil(face_w / (0.8 * w))   # keep 10% margin on each side of the image
total = 4 * per_face + 12 + 8               # 4 faces, a 12-image ring at the antennas, 8 at the base
print(f"farthest distance for {ITEM_MM / PX:.2f} mm GSD: {d_max:.1f} m")
print(f"at {STANDOFF:.0f} m: GSD {gsd:.2f} mm, image {w:.2f} x {h:.2f} m on the face")
print(f"{rows} rows per face, {per_face} images per face, {total} images in all")
print(f"at 3 s per image: about {total * 3 / 60:.0f} min of capture")
farthest distance for 1.25 mm GSD: 17.2 m
at 12 m: GSD 0.87 mm, image 4.61 x 3.46 m on the face
34 rows per face, 51 images per face, 224 images in all
at 3 s per image: about 11 min of capture

The farthest distance that still gives a 1.25 mm GSD is about 17 m. A 12 m stand-off therefore leaves a wide margin over the minimum near structures computed in module 2 (about 4 m) and keeps clear of guy wires and antennas, while giving a 0.87 mm GSD. Each image covers about 4.6 × 3.5 m of a face, so below about 23 m, where the face is wider than 3.7 m, two columns are needed; above that one is enough. About 224 images take about 11 minutes of capture, but moving between faces and changing batteries make the real flight longer, so one battery per face is a safe plan. Unlike the wall, a tower is small enough to be captured at full detail everywhere; the two-level idea is for large surfaces, not for a single tower.

Before flying

  • Scope: which parts of the structure to inspect, what size of defect must be seen, and the delivery format
  • Existing information: drawings, previous inspection reports and earlier images for comparison
  • Permissions: flight under the current CAAT notification, the building owner’s permission, and notice to building users, because the camera may see people in rooms
  • Location reference system: name building faces, floors and column bays, or piers and spans for the bridge, so defect locations can be stated in the report

Module lab

Lab: a wall inspection plan

  1. Choose one building wall on campus and measure or estimate its width and height
  2. Agree the smallest crack and pixel count with your lecturer, and compute GSD and stand-off for the available lenses with the code in Example 1
  3. Compute the number of images at two resolutions with the code in Example 2
  4. Survey the wall from the ground by eye or binoculars and identify at least five spots needing detail
  5. Set up a location reference system on the wall (face, floor, column bay) and write a one-page inspection plan

Common mistakes

Watch out

  • Starting from the drone model or a familiar distance instead of the defect size to be seen
  • Promising the user that drones replace all inspection, when contact tasks still need people
  • Capturing the whole wall at the highest resolution, producing more images than anyone can review
  • No location reference system, so nobody can say where a crack in an image is on the building
  • Not notifying building users, even though the camera may see people in rooms
  • Flying a telecom tower without agreeing with the operator which antennas will be transmitting, or trusting obstacle sensors to see guy wires

Summary

  • Drones supplement qualified inspectors; they do not replace contact tasks or the engineer’s judgement
  • Key concrete defects are cracks, spalling, efflorescence, rust staining and delamination
  • Start from the smallest defect and agreed pixel count, then compute GSD and
  • A telephoto lens gives the same detail from farther away, which is safer
  • Inspect at two levels: the whole wall at a coarse GSD, then detail at selected spots
  • Towers are flown face by face in vertical columns plus rings at antenna level and at the base; ANSI/TIA-222 Annex J lists what to check, and live conductors, transmitting antennas, guy wires and wind at height are the specific hazards

Check your understanding

  1. To see a 2 mm crack spanning 4 pixels, what GSD is needed?
  2. With a 0.5 mm GSD, a 25 mm lens and a 17.3 mm, 5,280-pixel sensor, how far from the wall must the camera be?
  3. How often does ANSI/TIA-222 recommend assessing a self-supporting telecom tower and a guyed mast, and when else?
  4. Which tasks can drones not take over from inspectors?
  5. Why is two-level inspection recommended?
Answers
  1. mm
  2. m
  3. Every five years for a self-supporting tower and every three years for a guyed mast, after severe wind or ice storms, and more often in coastal or corrosive places
  4. Contact tasks such as sounding, measuring steel thickness and coring, and judging the structure’s condition
  5. Very detailed images cover little area, so whole-wall detail would need an enormous number of images; survey coarsely first, then detail selected spots

Key formulas

Required GSD
Stand-off distance
Number of images

Key references

  1. Federal Highway Administration. (2022). National bridge inspection standards (Final rule). Federal Register, 87(88), 27396. 23 CFR 650 Subpart C. link
  2. Lee, S. B., Lee, D. H., & Kim, J. (2026). An exploratory study on imaging resolution, operational parameters, and measurement uncertainty in UAV-based crack inspection. Sensors, 26(3), 1031. link
  3. Barnhart, R. K., Marshall, D. M., & Shappee, E. (Eds.). (2021). Introduction to unmanned aircraft systems (3rd ed.). CRC Press. link
  4. Wolf, P. R., DeWitt, B. A., & Wilkinson, B. E. (2014). Elements of photogrammetry with applications in GIS (4th ed.). McGraw-Hill Education. link
  5. สำนักงานการบินพลเรือนแห่งประเทศไทย. (2569). ประกาศ กพท. เรื่อง หลักเกณฑ์และวิธีการในการอนุญาตให้ผู้บังคับหรือปล่อยอากาศยานซึ่งไม่มีนักบิน ประเภทอากาศยานที่ควบคุมการบินจากภายนอก ที่มีน้ำหนักไม่เกิน 25 กิโลกรัม ปฏิบัติแตกต่างไปจากเงื่อนไขที่กำหนด พ.ศ. 2569 (มีผล 17 พฤษภาคม 2569). link
  6. Kisting, S., & Erichsen, J. (2017, May/June). ANSI/TIA-222 maintenance and condition assessment of telecommunication towers [Planning advisory notice]. Tower Times. Telecommunications Industry Foundation. link
  7. Stekr, S., Recinos, L., & Kisting, S. (2024). ANSI/TIA-222-I update [Planning advisory notice]. Telecommunications Industry Foundation. link
  8. ASTM International. (2025). Standard practice for evaluating degree of rusting on painted steel surfaces (ASTM D610-25). link
  9. การไฟฟ้าฝ่ายผลิตแห่งประเทศไทย. (2566). ความปลอดภัยจากสายไฟฟ้าแรงสูง [บทความเผยแพร่]. link

Further reading

Study the assigned knowledge units in advance, review media and take the module quiz

In class / field

Lab or field practice from worksheets with a safety checklist

Learning evidence: Checked worksheets and quiz results

Module quiz

This is a formative self-check, not a graded exam

Knowledge domain: Inspection, industry and surveillance · Aircraft, structures and design