UAT 453 UAS for Infrastructure, Energy and Utility Inspection
Worksheet 9 Thermal imaging of solar panels
Objective
Image solar panels thermally under correct conditions, classify anomalies, estimate lost energy and prioritise repairs
Equipment and materials
- Drone or mast with thermal and RGB cameras
- Irradiance meter (pyranometer or reference cell)
- Real module power data
- Computer with Python and the module 9 example code
Safety
- Work under the lecturer's and building owner's supervision
- If flying, do so within CAAT conditions in visual line of sight with people clear
- Beware roof edges and sun heat; drink water and wear a hat
- Never touch the modules or solar wiring
Steps
- Compute the maximum height for the thermal camera and cell size with Example 1
- Measure plane-of-array irradiance
- Capture thermal images above 600 W/m² with paired RGB images
- Classify anomalies by the lesson's patterns and find causes from RGB
- Estimate lost energy with Example 2
- Recommend which modules to repair first, with reasons
Record of results
| Item | Value | Unit | Condition met? |
|---|---|---|---|
| Panel position (row-number) | Thermal pattern | Cause from RGB | Power fraction lost | Energy lost (kWh/yr) |
|---|---|---|---|---|
Questions
Was your real flight height below the maximum, and what would you miss flying higher?
What was the irradiance during your images, and what should you do if cloud drops it below 600 W/m²?
Did your hot spots come from panel faults or something else, such as bird droppings, shading or reflections? Use the paired RGB images.
Why should panels not be replaced from thermal images alone?
Check before you hand in
What to hand in
- Height calculation and irradiance readings
- Paired thermal and RGB images labelled by module
- Anomaly and energy-loss table
- Repair priority recommendation