Module 7/10 · Weeks 10–11 · 14 h

Thermal camera operation and settings

UAT 455 Sensor, Camera and Thermal Imaging Technology for UAS

About 95 minDraft, awaiting reviewLast updated 1 October 2026

Lesson

By the end of this module you will be able to

  1. Explain how a microbolometer works and calculate the signal chain of one pixel, from a 1 K temperature difference in the scene to the converter count
  2. Estimate NETD from noise and counts per kelvin, and explain that NETD depends on the lens f-number
  3. Separate temporal noise from sensor fixed-pattern noise, and explain what shutter correction (FFC) does and does not fix
  4. Calculate the effect of the microbolometer time constant on a small target while the drone is flying
  5. Set the temperature range, gain, level and span, palette and object parameters for night search, and explain how auto range can make a person's contrast disappear

Prerequisites: Module 6 Thermal radiation, apparent temperature and emissivity

Why this matters

At 22:40 the camera operator of the volunteer search team of Thung Sommuti sub-district (fictional name) opened the live thermal feed on the first flight of the night and found almost the whole image a flat dark grey, with no visible difference between the rice-field bunds and the water. The cause was a water pump in a hut beside the canal, glowing hot in the frame. Auto-range mode stretched the scale to cover everything from the cold ground to the pump, so the few degrees of contrast from a person shrank to just a few grey levels. The fix did not need a different camera. It needed an understanding of how the camera works and what each control changes. This module walks from the sensor to the settings used in the field.

From sensor to number in the image

Almost every drone thermal camera uses a microbolometer sensor, which needs no cooling. Rogalski (2012) reports that microbolometers held more than 95% of the uncooled infrared detector market in 2010, and the most widely used materials are vanadium oxide (VOx) and amorphous silicon (a-Si). According to DJI’s spec sheet, the drone camera used in this course has a VOx sensor with a 12 µm pixel pitch, 640 × 512 resolution, a 30 Hz frame rate, an f/1.0 lens and a 45° diagonal field of view, and it is sensitive in the 8–14 µm band.

The principle has four steps. One, infrared radiation that passes through the lens falls on an absorber plate the size of a pixel, suspended on thin bridges that insulate it thermally from the silicon base. Two, the absorbed energy warms the plate slightly. Three, the electrical resistance of the material on the plate changes with temperature, in a proportion called the temperature coefficient of resistance (TCR). Four, the readout circuit converts the resistance change to a voltage, and an analogue-to-digital converter turns it into a count. Rogalski (2012) states that pixel sensitivity can be raised by increasing the fill factor, absorption, TCR and bias voltage, or by lowering the thermal conductance of the bridge () and the resistance. The same review points out that the detection range of many uncooled systems is limited by pixel resolution more than by sensitivity, which is why manufacturers have shrunk pixels to 12 µm.

Example 1 How many counts does a 1 K difference in the scene become

Use from Module 6 and the parameters of the f/1.0 camera with 12 µm pixels. Values not in the spec are assumed: lens transmission 0.9, pixel absorption 0.7, bridge thermal conductance W/K and TCR 3 %/K (the same order as the 3.2–3.9 %/K that Rogalski (2012) reports for silicon alloys). The high-gain range of −20 to 150 °C, per the spec, is assumed to map to the full 14-bit count range linearly in radiance, with 3.5 counts of noise.

import math
import numpy as np
H, K, C = 6.62607015e-34, 1.380649e-23, 299792458.0
C2 = 1.438776877e-2
lam = np.linspace(8e-6, 14e-6, 601)
def band_radiance(t_c):                              # radiance in the 8-14 um band, as in Example 1 of Module 6
    t = np.asarray(t_c, dtype=float) + 273.15
    l = 2 * H * C**2 / lam**5 / (np.exp(C2 / (lam * t[..., None])) - 1)
    return np.trapezoid(l, lam, axis=-1)
PITCH, F_NUM, TAU_OPT = 12e-6, 1.0, 0.9               # pixel pitch, f-number, lens transmission (assumed)
G_TH, ABSORB, TCR = 1.0e-7, 0.7, 0.03                 # bridge and material values (assumed)
dL = band_radiance(31.0) - band_radiance(30.0)        # radiance difference when the scene differs by 1 K at 30 C
sin2 = 1 / (1 + 4 * F_NUM**2)
phi = dL * PITCH**2 * TAU_OPT * math.pi * sin2        # power falling on one pixel (W)
dT_b = ABSORB * phi / G_TH                            # temperature rise of the absorber plate
print(f"power change on one pixel per scene kelvin {phi * 1e12:.1f} pW")
print(f"bolometer temperature rise {dT_b * 1e3:.2f} mK, relative resistance change {TCR * dT_b:.2e}")
span = band_radiance(150.0) - band_radiance(-20.0)
cpk = dL / span * 16383                               # counts per kelvin at 30 C
NOISE = 3.5
netd = NOISE / cpk
print(f"high gain: {cpk:.1f} counts per K, NETD {netd * 1000:.0f} mK for {NOISE:.1f} counts noise")
for f in (1.0, 1.4, 2.0):
    ratio = (1 + 4 * f**2) / (1 + 4 * 1.0**2)
    print(f"f/{f:.1f}: NETD x{ratio:.2f} -> {netd * ratio * 1000:.0f} mK")
power change on one pixel per scene kelvin 70.5 pW
bolometer temperature rise 0.49 mK, relative resistance change 1.48e-05
high gain: 73.9 counts per K, NETD 47 mK for 3.5 counts noise
f/1.0: NETD x1.00 -> 47 mK
f/1.4: NETD x1.77 -> 84 mK
f/2.0: NETD x3.40 -> 161 mK

This chain shows how small the signal is. A 1 K difference in the scene changes the power on the pixel by only 70.5 picowatts, warms the absorber plate by 0.49 mK and changes the resistance by a relative 1.5 × 10⁻⁵. Making that readable depends on bridges that insulate well, vacuum sealing and a low-noise readout circuit. On the digital side, the high-gain range, 170 K wide, maps to 16,383 counts, which gives 73.9 counts per kelvin at 30 °C, and 3.5 counts of noise is equivalent to an NETD of 47 mK, below DJI’s spec of ≤ 50 mK at f/1.0.

NETD (noise equivalent temperature difference) is the smallest temperature difference that can be separated from noise. Manufacturers should state it at 30 °C, the standard used for comparison (Teledyne FLIR), and DJI’s spec also gives NETD at f/1.0. The figure depends on the f-number because the power falling on a pixel from an emitting scene equals the radiance times the pixel area times the solid angle the lens opens up, which scales as (about when is large). Going from f/1.0 to f/1.4 reduces the signal to 56.5% and raises NETD to 1.77 times (84 mK), and at f/2.0 it is 3.40 times (161 mK). A telephoto lens, or any lens with a higher f-number, therefore gives a noisier image, which is consistent with the Infiniti Optics document stating that NETD depends on both the sensor and the lens f-number. All the assumed variables may differ from a real camera, so use them only for the order of magnitude and the direction of the effect.

Horizontal bar chart of NETD against lens f-number, three bars: f/1.0 47 millikelvin, f/1.4 84 millikelvin, f/2.0 161 millikelvin. The pink dashed line at 50 millikelvin is the maximum spec value at f/1.0
Figure 1 NETD of the example camera against lens f-number

Temporal noise, fixed pattern and FFC

NETD describes only the noise that changes from frame to frame. Real images contain another kind, fixed-pattern noise, because each pixel has a slightly different offset and gain. This pattern does not change from one frame to the next, so it looks like a fixed tile pattern or lines in the image, and averaging many frames does not help. The camera corrects it with flat-field correction (FFC), which closes a shutter so that every pixel looks at the same surface, then uses that image to subtract the offset differences. Rashman et al. (2020), who used a FLIR microbolometer with an internal shutter, report that the shutter closes periodically at intervals of about 2.5 minutes, with extra closures when the ambient or sensor temperature changes a lot. This reduces drift, which makes the counts creep upward until the camera corrects itself. While the shutter is closed the image freezes briefly, so do not press the capture or confirm-target button at that moment.

Example 2 Measuring NETD and fixed pattern from a synthetic image set

Simulate a 16 × 16 pixel sensor imaging a flat black-body plate for 60 frames, with a per-pixel offset σ = 25 counts, a per-pixel gain σ = 0.2% and temporal noise of 3.5 counts (all assumed values). Then correct the offset with one set of shutter frames at the same temperature as the scene, and test scenes 2 K and 20 K warmer than the shutter.

rng = np.random.default_rng(481)
S0 = 8000.0                                           # scene signal in counts
gain = 1 + rng.normal(0, 0.002, (16, 16))             # per-pixel gain
off = rng.normal(0, 25.0, (16, 16))                   # per-pixel offset
def shoot(s, n=60):
    return (gain * s + off)[None] + rng.normal(0, NOISE, (n, 16, 16))
frames = shoot(S0)
temporal = frames.std(axis=0, ddof=1).mean()
print(f"temporal noise {temporal:.2f} counts -> NETD {temporal / cpk * 1000:.0f} mK")
fpn = frames.mean(axis=0).std()
print(f"fixed pattern before correction {fpn:.1f} counts = {fpn / cpk * 1000:.0f} mK")
shut = shoot(S0).mean(axis=0)                         # image while the shutter is closed (same temperature as the scene)
offset_est = shut - shut.mean()
for dt in (0.0, 2.0, 20.0):
    s = S0 + dt * cpk
    img = shoot(s).mean(axis=0) - offset_est
    print(f"scene {dt:4.1f} K from shutter temperature: pattern {img.std() / cpk * 1000:5.0f} mK")
temporal noise 3.48 counts -> NETD 47 mK
fixed pattern before correction 29.6 counts = 400 mK
scene  0.0 K from shutter temperature: pattern     9 mK
scene  2.0 K from shutter temperature: pattern     9 mK
scene 20.0 K from shutter temperature: pattern    40 mK

The temporal noise measures 3.48 counts, matching the NETD of 47 mK that was set up, but the fixed pattern before correction is 29.6 counts, or 400 mK, more than eight times the NETD. The raw image is therefore full of texture that comes from the sensor itself. After shutter correction the pattern falls to about 9 mK (part of which is temporal noise remaining after averaging 60 frames). With the scene 2 K warmer than the shutter it stays at 9 mK, but with the scene 20 K warmer, for example when a hot engine is in view, the pattern rises to 40 mK. This happens because single-point shutter correction removes only the offset differences, not the gain differences, which grow with the difference between the scene and the shutter. The field conclusion is to warm up the camera and let it complete flat-field correction before searching, and not to interpret faint patterns that appear near hot spots as objects.

Time constant: when the camera cannot keep up with the drone

The signal of a microbolometer does not change instantly when the scene changes, because the absorber plate must first warm up or cool down. Oswald-Tranta (2017) reports that the pixel signal decays exponentially with a time constant of 10–15 ms (typically about 10 ms), unlike cooled cameras, which expose for only 1–1.5 ms. When an object moves, the image therefore has a “tail”, and that paper shows that a 45 °C warm ball moving at 1 m/s reads only about 35 °C. The next example uses a simple first-order model. If a target stays on one pixel for , the peak signal at that pixel reaches the fraction of the full value, where is the time constant. A target pixels wide reaches (this expression was formulated for this course and is not a manufacturer’s formula).

Example 3 How much of a small target is lost when flying fast

A 12 µm camera with a 45° diagonal field of view flies at heights of 40, 80 and 120 m (120 m is above the 90 m ceiling of the general conditions discussed in Module 10, so it is used only to show the trend) at speeds of 4 and 8 m/s. Use ms, the typical value from Oswald-Tranta (2017). The focal length is found from the diagonal field of view, as in UAT 460.

PITCH_M, DFOV, NX, NY = 12e-6, 45.0, 640, 512
f = math.hypot(NX, NY) * PITCH_M / 2 / math.tan(math.radians(DFOV / 2))
TAU_TH = 0.010                                        # microbolometer time constant, 10 ms
print(f"focal length {f * 1000:.1f} mm")
for h in (40, 80, 120):
    gsd = PITCH_M * h / f
    for v in (4.0, 8.0):
        t_pix = gsd / v                               # time the target stays on one pixel
        one = 1 - math.exp(-t_pix / TAU_TH)
        three = 1 - math.exp(-3 * t_pix / TAU_TH)
        print(f"{h:3d} m {v:3.0f} m/s: GSD {gsd * 100:4.1f} cm, dwell {t_pix * 1000:5.1f} ms, 1-px target reaches {100 * one:4.1f} %, 3-px {100 * three:4.1f} %, tail 3tau = {3 * TAU_TH * v / gsd:4.1f} px")
focal length 11.9 mm
 40 m   4 m/s: GSD  4.0 cm, dwell  10.1 ms, 1-px target reaches 63.6 %, 3-px 95.2 %, tail 3tau =  3.0 px
 40 m   8 m/s: GSD  4.0 cm, dwell   5.1 ms, 1-px target reaches 39.7 %, 3-px 78.0 %, tail 3tau =  5.9 px
 80 m   4 m/s: GSD  8.1 cm, dwell  20.2 ms, 1-px target reaches 86.8 %, 3-px 99.8 %, tail 3tau =  1.5 px
 80 m   8 m/s: GSD  8.1 cm, dwell  10.1 ms, 1-px target reaches 63.6 %, 3-px 95.2 %, tail 3tau =  3.0 px
120 m   4 m/s: GSD 12.1 cm, dwell  30.3 ms, 1-px target reaches 95.2 %, 3-px 100.0 %, tail 3tau =  1.0 px
120 m   8 m/s: GSD 12.1 cm, dwell  15.2 ms, 1-px target reaches 78.0 %, 3-px 98.9 %, tail 3tau =  2.0 px

At 80 m (GSD 8.1 cm) and 8 m/s, a one-pixel target stays on the pixel for only 10.1 ms and so reaches only 63.6% of its full signal. A 5 K temperature difference would shrink to about 3.2 K. At 40 m, where the GSD falls to 4.0 cm, it reaches only 39.7%. By contrast, a target three pixels wide still reaches 95.2% at 80 m, and a whole person (several pixels wide) loses almost no signal. The time constant therefore matters for small targets, such as embers or a face seen in only a few pixels. At the lower speed of 4 m/s, the signal of a one-pixel target at 80 m is 86.8%. The image tail of three time constants (3τ) equals 3.0 pixels at 80 m and 8 m/s, so a tail must not be read as another object.

Horizontal bar chart of six bars showing the peak signal reached by a one-pixel target. At 40 metres: 63.6 percent at 4 metres per second and 39.7 at 8. At 80 metres: 86.8 and 63.6. At 120 metres: 95.2 and 78.0
Figure 2 Peak signal of a one-pixel target at various heights and speeds (τ = 10 ms)

Settings the operator chooses

Temperature range or gain mode. A microbolometer camera has no adjustable exposure time like an RGB camera, so the operator chooses the temperature range, which makes the full count range match the radiance coming from the scene. If the range is too low, the image saturates on hot objects. If it is too high, the image is “underexposed”. Teledyne FLIR (2019) advises choosing the lowest range that still covers the highest temperature in the image. For the camera used in this course, DJI’s spec gives high gain measuring −20 to 150 °C with an accuracy of ±2 °C or ±2% (whichever is greater), and low gain measuring 0 to 550 °C with an accuracy of ±5 °C or ±3%. In practice, use high gain when searching for people and switch to low gain when you need to view objects hotter than 150 °C, such as embers (Module 9). The spec document also warns against pointing the infrared lens at strong energy sources such as the sun, lava or lasers, because the sensor can be permanently damaged (DJI).

Level and span, and auto range. Teledyne FLIR (2019) explains that in automatic mode the camera takes the lowest and highest apparent temperature in the image as the lower and upper limits of the displayed range. Manual adjustment (thermal tuning) lets the user set which temperature range all the colours of the palette are spread over. That document states that scaling the image to suit the task is an important step in interpreting an image and is often underestimated. The next example shows why.

Palette. A palette converts signal level to colour. Teledyne FLIR (2019) states that greyscale palettes suit separating shape detail but are poor at showing small temperature differences. The iron palette balances shape detail with temperature detail and is easy for unfamiliar users to understand. The rainbow palette gives high contrast between differences but makes the image busy when there are many surface types or temperatures. DJI’s spec lists 10 palettes: White Hot, Black Hot, Tint, Iron Red, Hot Iron, Arctic, Medical, Fulgurite, Rainbow 1 and Rainbow 2. The camera operator should choose one palette for searching (for example White Hot or Black Hot, which are greyscale palettes suited to shape detail, as Teledyne FLIR states) and another for confirming a hot spot (for example Iron Red), and keep the same ones throughout the flight, because changing the palette mid-mission makes images from different times impossible to compare. No verified document yet gives evidence that any particular palette helps image analysts find more people, so a team should test with its own image analysts in operations.

Isotherm. An isotherm is a function that colours a chosen band of apparent temperature with a colour different from the palette, to highlight heat patterns (Teledyne FLIR, 2019). Use it to highlight every point warmer than a set threshold. Check whether the camera model has this function, because the DJI spec that was read lists spot and area measurement (Spot Meter, Area Measurement) but does not list the isotherm.

Object parameters and recording format. The values of ε, reflected temperature, distance, humidity and air temperature (Module 6) must be set or recorded. DJI’s spec allows still images to be recorded as both 8-bit JPEG and 16-bit R-JPEG (a JPEG that stores radiometric values). An 8-bit image with a range already applied cannot have ε corrected afterwards, so keep R-JPEG every time temperature readings are wanted. On resolution, the spec gives 640 × 512 pixels, and 1280 × 1024 pixels when Super Resolution is on, a mode whose processing method the spec page does not explain. In this course, count the pixels on a target from the 640 × 512 sensor with its 12 µm pixel pitch, and do not count pixels from processing modes.

Example 4 Auto range, locked range and count resolution

Build a 32 × 32 pixel scene: damp rice-field ground at 24 °C (noise 0.05 K), a person blob 5 × 2 pixels wide at 29 °C, and a hot water pump at 110 °C, 3 × 3 pixels (assumed values). Compare three 8-bit displays: an auto linear range, histogram equalisation, and a locked 15–45 °C range. Then compare the temperature step per count (LSB) of high gain and low gain.

rng2 = np.random.default_rng(7)
t = 24.0 + rng2.normal(0, 0.05, (32, 32))                # damp rice-field ground at 24 C
t[10:12, 8:13] = 29.0 + rng2.normal(0, 0.05, (2, 5))     # person blob, 5 x 2 pixels
t[24:27, 24:27] = 110.0                                  # hot water pump
def to8(img, lo, hi): return np.clip((img - lo) / (hi - lo), 0, 1) * 255
def equalise(img):
    flat = img.ravel(); ranks = np.argsort(np.argsort(flat))
    return (ranks / (flat.size - 1) * 255).reshape(img.shape)
modes = {"auto min-max": to8(t, t.min(), t.max()), "equalised": equalise(t), "locked 15-45 C": to8(t, 15.0, 45.0)}
bg = np.ones_like(t, bool); bg[10:12, 8:13] = False; bg[24:27, 24:27] = False
person = np.zeros_like(t, bool); person[10:12, 8:13] = True
for name, im in modes.items():
    print(f"{name:15s} background {im[bg].mean():6.1f}  person {im[person].mean():6.1f}  gap {im[person].mean() - im[bg].mean():6.1f} levels, background noise {im[bg].std():5.1f} levels")
print("temperature step per grey level: auto", round((t.max()-t.min())/255*1000), "mK; locked", round(30/255*1000), "mK")
for name, lo, hi in (("high gain", -20.0, 150.0), ("low gain", 0.0, 550.0)):
    per_k = (band_radiance(31.0) - band_radiance(30.0)) / (band_radiance(hi) - band_radiance(lo)) * 16383   # counts per kelvin at 30 C
    print(f"{name}: range / counts {1000 * (hi - lo) / 2**14:.1f} mK, step at 30 C {1000 / per_k:.1f} mK per count ({per_k:.1f} counts per K)")
auto min-max    background    0.5  person   15.2  gap   14.8 levels, background noise   0.1 levels
equalised       background  125.1  person  251.6  gap  126.5 levels, background noise  72.3 levels
locked 15-45 C  background   76.5  person  118.9  gap   42.4 levels, background noise   0.4 levels
temperature step per grey level: auto 338 mK; locked 118 mK
high gain: range / counts 10.4 mK, step at 30 C 13.5 mK per count (73.9 counts per K)
low gain: range / counts 33.6 mK, step at 30 C 89.3 mK per count (11.2 counts per K)

With auto range, the scale is 86 K wide, from the 24 °C ground to the 110 °C pump, so each grey level is 338 mK. The person, 5 K above the ground, is left with only 14.8 levels out of 255, and the ground is almost pure black (mean 0.5). With the range locked at 15–45 °C, 30 K wide, each level is 118 mK and the person’s difference is 42.4 levels, almost three times more, without changing the camera or the scene. The pump saturates to pure white, which is acceptable because it is a heat source the team already knows about. Histogram equalisation makes the person very bright (126.5 levels apart) but also amplifies the ground noise to a standard deviation of 72.3 levels, and it destroys the linear relationship between grey level and temperature (Szeliski, 2022 explains that histogram equalisation distributes levels according to how often values occur, not according to the size of the differences). It therefore suits viewing shapes more than comparing heat. On conversion to counts, dividing the width of the range by the number of counts gives 10.4 mK in high gain and 33.6 mK in low gain, but that is only an average over the whole range, because radiance is not linear in temperature. At a 30 °C scene the actual step is 13.5 mK per count in high gain (73.9 counts per kelvin, matching Example 1) and 89.3 mK in low gain (11.2 counts per kelvin). The low-gain step is therefore about 6.6 times coarser and almost twice the 47 mK NETD of high gain. If the noise stayed at 3.5 counts, the low-gain NETD would be about 313 mK, so low gain is unsuitable for searching for people.

Horizontal bar chart of three groups with two bars each: the difference between person and ground in grey levels, and the ground noise. Auto range 14.8 and 0.1; histogram equalisation 126.5 and 72.3; locked range 15 to 45 degrees 42.4 and 0.4
Figure 3 Person-to-ground difference and ground noise for the three display methods (grey levels 0–255)

Starting settings for a search night

The Thung Sommuti team summarised its starting settings for a night flight as follows. Use high gain and lock the range at 15–45 °C (covering cold ground, warm water and people). Turn on the isotherm at a 45 °C threshold to highlight heat sources (if that camera model has the function). Use the White Hot palette throughout the flight. Record R-JPEG for every still image. Limit flight speed to no more than 5 m/s so the time constant does not reduce the signal. Let the camera warm up and complete flat-field correction before the search starts. Note the object parameters (ε 0.95, reflected temperature measured with foil, humidity and temperature from a weather station or a meter at the launch point). All of these are starting values that the team must test and adjust with this module’s lab, not values that work for every mission.

Module lab

Lab: measuring NETD, fixed pattern and the effect of range settings

  1. Image a smooth object at uniform temperature (for example a wall, or an aluminium plate painted matt black and left in the room for a long time) with a thermal camera the department has, for 100 frames or more at the high-gain range. Save the frames as a raw image set or R-JPEG.
  2. Compute the temporal standard deviation per pixel and the fixed pattern across pixels with code adapted from Example 2, then convert to mK using the counts per kelvin found from the difference between two object temperatures.
  3. Trigger flat-field correction or wait for the shutter to close, then compare the fixed pattern before and after. Place a source 20 K warmer in view and see whether the pattern increases.
  4. Build a scene with a small heater (or a covered kettle of hot water) beside the holder, in place of a person. Image it with auto range and with the locked 15–45 °C range, and with high gain and low gain. Compare the difference in grey levels with code like that in Example 4.
  5. Hold the camera and pan across a small target (a warm water bottle 5 cm in diameter) at various speeds. Measure the target’s peak signal, compare it with the formula , and estimate the camera’s .
  6. Compare the White Hot, Black Hot, Iron Red and Rainbow palettes with at least three image analysts who do not know where the targets are. Count the number of targets found with each palette.

Safety: never point the infrared lens at the sun, a laser or any strong energy source. All of this work is done on a bench or a tripod, with no flying.

Common mistakes

Watch out

  • Leaving the camera in auto range when a hot source is in view: the person’s contrast disappears, so lock the range
  • Using low gain when searching for people: the count steps are coarse and accuracy drops
  • Comparing the NETD of cameras quoted at different f-numbers without normalising them
  • Thinking a low NETD means the image has no pattern: sensor fixed pattern is a separate matter and comes back when the scene differs a lot from the shutter
  • Flying so fast that the time constant reduces the signal of small targets, then concluding there is no heat
  • Changing the palette or range mid-mission and then comparing images from different times directly
  • Keeping only 8-bit images or compressed video and then wanting to read temperatures later

Summary

  • A microbolometer turns radiation into heat on a thin bridge, then into a resistance change, then into a count. A 1 K difference in the scene changes the resistance by only about of its value, so good thermal insulation and a good readout circuit are essential.
  • NETD = noise divided by counts per kelvin. It depends on the f-number as , so f/1.4 is about 1.8 times worse than f/1.0.
  • Sensor fixed pattern is several times larger than NETD before FFC. FFC removes the offset differences but not the gain differences, so more remains when the scene differs a lot from the shutter.
  • A time constant of about 10 ms reduces the signal of small targets when flying fast (63.6% for a one-pixel target at 80 m and 8 m/s). Fly slower or use targets several pixels wide.
  • Lock the range and use high gain when searching for people, and use low gain when there are objects above 150 °C. Choose one palette, use the isotherm to highlight heat sources, and record R-JPEG together with the object parameters.

Check your understanding

  1. A camera has an NETD of 47 mK at f/1.0. If you switch to an f/1.6 lens, about what will the NETD be?
  2. With a GSD of 6 cm at a speed of 6 m/s and a time constant of 10 ms, what percentage of its signal does a one-pixel target reach?
  3. How many grey levels per kelvin does a locked range of 10–40 °C give, and how many levels apart is a person 4 K warmer than the ground? If the auto range is 115 K wide (15 °C ground to a 130 °C engine), how many levels apart?
  4. Low gain spans 550 K mapped to 14 bits. What is the average step (width of the range divided by the counts) in mK per count, and how many times coarser is it than high gain over 170 K?
  5. The gain non-uniformity between pixels is σ = 0.2% and the scene is 30 K warmer than the shutter. About how many mK of fixed pattern remain after FFC?
Answers
  1. The ratio is , so the NETD is about mK
  2. ms , so , or 63.2%
  3. Locked range: levels per K, so a person 4 K warmer differs by levels. Auto range: levels per K, so the difference is levels
  4. K, or 33.6 mK per count. High gain is mK, so low gain is about 3.2 times coarser on average over the whole range (at a 30 °C scene the actual low-gain step is about 6.6 times coarser than high gain, because radiance is not linear in temperature)
  5. The gain difference times the temperature difference is K, or about 60 mK

Key formulas

Power falling on one pixel
NETD from noise and counts per kelvin
Change of NETD with f-number
Peak signal of a one-pixel target while moving

Key references

  1. Rogalski, A. (2012). History of infrared detectors. Opto-Electronics Review, 20(3), 279–308. link
  2. Teledyne FLIR. Comparing sensitivity of thermal imaging cameras and modules (NETD). link
  3. Infiniti Optics. (n.d.). What is f-stop and why is the f-number of the lens so important for thermal infrared cameras? [White paper]. link
  4. DJI. Matrice 4 series specs (O4 Enterprise video transmission). link
  5. Rashman, M. F., Steele, I. A., Bates, S. D., Copley, D., & Longmore, S. N. (2020). Uncooled microbolometer arrays for ground-based astronomy. Monthly Notices of the Royal Astronomical Society, 492(1), 480–487. link
  6. Oswald-Tranta, B. (2017). Motion deblurring of infrared images. In Proceedings of SENSOR 2017 and IRS² 2017 (pp. 783–787). AMA Association for Sensors and Measurement. link
  7. FLIR Systems, Inc. (2019). Reference documentation: Thermography (Publication No. T810442). Teledyne FLIR. link
  8. Szeliski, R. (2022). Computer vision: Algorithms and applications (2nd ed.). Springer. link

Further reading

Study the assigned knowledge units in advance, review media and take the module quiz

In class / field

Lab or field practice from worksheets with a safety checklist

Learning evidence: Checked worksheets and quiz results

Module quiz

This is a formative self-check, not a graded exam

Knowledge domain: Inspection, industry and surveillance · Sensors and embedded systems · Public safety and disasters