Module 6/10 · Weeks 9 · 14 h

Thermal radiation, apparent temperature and emissivity

UAT 455 Sensor, Camera and Thermal Imaging Technology for UAS

About 95 minDraft, awaiting reviewLast updated 24 October 2026

Lesson

By the end of this module you will be able to

  1. Calculate the radiation a thermal camera receives in the 8–14 µm band from Planck's law, and explain why the signal is more sensitive to temperature than the T⁴ formula suggests
  2. Explain the definition of apparent temperature, and use the measurement equation with its object, reflected and atmospheric terms to recover the true surface temperature of an object
  3. Assess how a low ε magnifies an error in the reflected temperature by a factor of (1 − ε)/ε
  4. Calculate the emissivity of water by viewing angle with the Fresnel equations, and explain the effect on oblique views over paddy fields and canals
  5. Choose a field method for measuring the apparent reflected temperature and ε by following the procedures given in the standards and by the manufacturer

Prerequisites: Modules 1–5 of this course (Sensor and Surveillance Camera Technology, recommended) · UAT 104 Computer Programming (recommended)

Why this matters

A thermal camera does not hand over a temperature directly. It measures the infrared radiation falling on its sensor and then converts it to a number using values the user has entered (emissivity, distance, humidity, reflected temperature). If those settings do not match the situation, the image still looks sharp and convincing, but the numbers can be wrong by several degrees. Search work does not always need absolute temperature, but it does need to know whether a bright or dark patch in the image comes from the object’s own heat or from the reflection of a cold sky, and how far the differences you see can be trusted.

This part of the course (Modules 6 to 10) uses a single assumed case throughout: the volunteer search team of Thung Sommuti sub-district (fictional name) in the central plains, a patchwork of paddy fields cut by irrigation canals, field bunds, a hut in the middle of the fields, and plots of organic soil along the canal where villagers often pile and burn rice straw. On the night of 14 November (assumed) at 22:10, relatives report that a 78-year-old man with early-stage dementia left home at about 20:30. That night the air is about 25 °C (falling to about 22 °C before dawn), relative humidity is about 80%, the sky is clear and the wind is light. The drone team of the local disaster prevention and mitigation unit has a drone carrying a thermal camera of 640 × 512 pixels, 12 µm pixel pitch and 8–14 µm band, like the model used in UAT 460 (according to DJI’s specification document), and has been granted permission for night flights in advance (assumed). Later, in the early morning, the village head reports a smell of smoke from a straw pile beside the organic-soil plot near the canal. The team must check whether there is a smouldering fire (embers without flame). All place names, people and numbers in this course are assumed values. The Python code can be downloaded at /downloads/uat-455/.

This course does not duplicate UAT 460, which teaches search theory, search areas and the number of pixels on a person. Instead it goes deep into the physics of thermal images, camera settings, environmental effects, image reading and the reliability of the data. It also builds on modules 1–5 of this course, which already explained Wien’s displacement law and the effect of setting ε = 1.0. This module does not repeat those two topics but follows the whole measurement chain onward.

From object surface to camera signal

The radiation entering the camera from one point in the image arrives by three paths at once (Teledyne FLIR, 2019). The first is radiation the object’s surface emits itself, which tells the object’s temperature. The second is radiation from the surroundings that the surface reflects, for example a cold sky or a warm hut. The third is radiation from the air between the object and the camera, which absorbs part of the radiation and adds emission of its own. The user must give the camera five values: the object’s emissivity, the apparent reflected temperature, the distance, the relative humidity and the air temperature. The camera then calculates back to the object temperature. This way of thinking lets every question in this course be answered with one question: which of these three signal contributions is the largest?

Planck’s law and the radiation in the camera band

A black body (an ideal object that absorbs and emits radiation perfectly) emits radiation according to Planck’s law. The spectral radiance , in W m⁻² sr⁻¹ m⁻¹, is

where is Planck’s constant, is the speed of light, and m K is the second radiation constant, whose value is exact under the 2022 CODATA definitions (NIST). Our camera responds only in the 8–14 µm band according to DJI’s specification document, so the radiation it can actually use is the integral over that band, . Vollmer and Möllmann (2017) explain that real cameras measure only their own band. The Stefan-Boltzmann formula, which covers all wavelengths, therefore shows the trend but is not the formula the camera uses.

Example 1 How sensitive is the 8–14 µm radiation to temperature?

Compute from 0 to 40 °C by numerical trapezoidal integration, and compare it with the all-wavelength radiance . Find the local exponent , the change per one kelvin, and the ratio of an ember at 450 °C (assumed value) to ground at 30 °C.

import numpy as np
H, K, C = 6.62607015e-34, 1.380649e-23, 299792458.0
C2 = 1.438776877e-2                          # second radiation constant hc/k (m K) from NIST CODATA 2022
SIGMA = 5.670374419e-8
lam = np.linspace(8e-6, 14e-6, 601)          # camera band 8-14 um
def band_radiance(t_c):
    t = np.asarray(t_c, dtype=float) + 273.15
    l = 2 * H * C**2 / lam**5 / (np.exp(C2 / (lam * t[..., None])) - 1)
    return np.trapezoid(l, lam, axis=-1)     # W m-2 sr-1
temps = np.array([0.0, 10.0, 20.0, 30.0, 40.0])
L = band_radiance(temps)
total = SIGMA * (temps + 273.15) ** 4 / np.pi
for t, l, tot in zip(temps, L, total):
    print(f"{t:4.0f} C: band radiance {l:6.2f} W/m2/sr, share of total {100 * l / tot:4.1f} %")
n = np.log(band_radiance(30.5) / band_radiance(29.5)) / np.log(303.65 / 302.65)
dL = band_radiance(31.0) - band_radiance(30.0)
print(f"local exponent n at 30 C: {n:.2f} (Stefan-Boltzmann would give 4)")
print(f"1 K at 30 C changes band radiance by {dL:.3f} W/m2/sr = {100 * dL / band_radiance(30.0):.2f} %")
print(f"ember 450 C vs ground 30 C: radiance ratio {band_radiance(450.0) / band_radiance(30.0):.1f}")
   0 C: band radiance  35.15 W/m2/sr, share of total 35.0 %
  10 C: band radiance  41.89 W/m2/sr, share of total 36.1 %
  20 C: band radiance  49.37 W/m2/sr, share of total 37.0 %
  30 C: band radiance  57.61 W/m2/sr, share of total 37.8 %
  40 C: band radiance  66.61 W/m2/sr, share of total 38.4 %
local exponent n at 30 C: 4.54 (Stefan-Boltzmann would give 4)
1 K at 30 C changes band radiance by 0.866 W/m2/sr = 1.50 %
ember 450 C vs ground 30 C: radiance ratio 17.0

The 8–14 µm band holds only about 35–38% of the total radiation of a room-temperature object; the rest lies outside the band. More important, the local exponent is 4.54, not 4. When the surface gets one percent hotter in kelvin, the radiation the camera sees rises by about 4.5 percent. At 30 °C a surface that is 1 K warmer gives 1.50% more radiation (0.866 W m⁻² sr⁻¹), a signal that a camera with an NETD of 50 mK can resolve. The 450 °C ember is 17.0 times brighter than the 30 °C ground in the same band. These numbers return in Module 7 (measurement range and saturation) and Module 9 (hot spots smaller than a pixel).

Apparent temperature and the measurement equation

Apparent temperature in thermography is the temperature of a black body that gives a signal equal to all the radiation entering the camera. Teledyne FLIR (2019) defines it as the value read from the instrument without compensation, which includes radiation from every path falling on the instrument. It is not the “feels-like” temperature reported in weather forecasts. This value differs from the true surface temperature when or when the air in between is not clear. The manufacturer gives the general measurement equation as

where is the radiation in the camera band, is the emissivity, and is the transmittance of the atmosphere between the object and the camera (). The first term is the radiation the object’s surface emits itself, at temperature . The second is the radiation of the surroundings, at temperature , reflected by the surface (the reflected fraction is for an opaque object). The third is the radiation of the air at temperature , which has an “emissivity” of (Teledyne FLIR, 2019). Once ε, τ, the reflected temperature and the air temperature are known, solve for and convert it back to a temperature, as the camera does internally.

Example 2 Four surface types on a clear night: what does the camera read?

At 02:00 the air is 24 °C, the sky is clear, and the apparent reflected temperature measured with a crumpled foil sheet is 8 °C ( at a range of 80 m). The four surfaces are the missing person’s cotton clothing (), paddy water (0.98), the hut’s weathered tin roof (0.30, assumed value) and a foil blanket (0.04). The true surface temperatures are assumed values. The numbers in this example (for instance τ = 0.92, clothing at 29 °C, water at 27 °C, and a water ε of 0.98, a common table value, against the 0.990 that Example 3 calculates looking straight down) are set only to teach the equation. Module 8 computes the surfaces and the atmosphere with a more detailed model and supplies the values used in Modules 9 and 10 (for instance τ = 0.946 at 80 m, clothing at 27.1 °C and water at 26.7 °C at 02:00), which supersede the values of this example.

grid = np.linspace(-40.0, 700.0, 3701)
Lg = band_radiance(grid)
to_temp = lambda l: float(np.interp(l, Lg, grid))   # band radiance -> black-body temperature
T_REFL, T_ATM, TAU = 8.0, 24.0, 0.92
surfaces = [("clothing (cotton)", 0.95, 29.0), ("paddy water", 0.98, 27.0),
            ("weathered tin roof", 0.30, 22.0), ("foil blanket", 0.04, 26.0)]
for name, eps, t_obj in surfaces:
    obj = eps * TAU * band_radiance(t_obj)
    refl = (1 - eps) * TAU * band_radiance(T_REFL)
    atm = (1 - TAU) * band_radiance(T_ATM)
    tot = obj + refl + atm
    app = to_temp(tot)                                 # what the camera sees without compensation
    back = to_temp((tot - refl - atm) / (eps * TAU))   # recovered with the correct parameters
    print(f"{name:18s} true {t_obj:4.1f} C -> apparent {app:5.1f} C | shares obj {100*obj/tot:4.1f}% refl {100*refl/tot:4.1f}% atm {100*atm/tot:4.1f}% | corrected {back:4.1f} C")
for name, eps, t_obj in surfaces[:3]:                  # reflected temperature set 10 K too high
    tot = eps*TAU*band_radiance(t_obj) + (1-eps)*TAU*band_radiance(T_REFL) + (1-TAU)*band_radiance(T_ATM)
    wrong = to_temp((tot - (1-eps)*TAU*band_radiance(T_REFL + 10) - (1-TAU)*band_radiance(T_ATM)) / (eps*TAU))
    print(f"{name:18s} Trefl set 10 K too high -> reads {wrong:5.1f} C (error {wrong - t_obj:+.1f} C)")
clothing (cotton)  true 29.0 C -> apparent  27.7 C | shares obj 89.1% refl  3.3% atm  7.6% | corrected 29.0 C
paddy water        true 27.0 C -> apparent  26.4 C | shares obj 90.9% refl  1.4% atm  7.7% | corrected 27.0 C
weathered tin roof true 22.0 C -> apparent  13.4 C | shares obj 31.7% refl 58.8% atm  9.5% | corrected 22.0 C
foil blanket       true 26.0 C -> apparent  10.1 C | shares obj  4.8% refl 85.2% atm 10.0% | corrected 26.0 C
clothing (cotton)  Trefl set 10 K too high -> reads  28.5 C (error -0.5 C)
paddy water        Trefl set 10 K too high -> reads  26.8 C (error -0.2 C)
weathered tin roof Trefl set 10 K too high -> reads  -2.1 C (error -24.1 C)

For clothing and water (), most of the signal comes from the object itself (89–91%). The reading is only 0.6–1.3 °C below the true value, mainly because the atmosphere absorbs 8% of the radiation and pulls the reading back with its own emission. For the weathered tin roof (), 59% of the signal is a reflection of the cold sky, so a roof that is truly at 22 °C shows as 13.4 °C. The foil blanket () shows as 10.1 °C although the foil surface is at 26 °C. The foil blanket is therefore seen as a cold spot almost as cold as the sky, not as a warm one.

The last three lines show something more important. If the reflected temperature is set 10 K too high, clothing is off by only −0.5 °C, but the roof is off by −24.1 °C, because the compensation subtracts reflected radiation that is not actually there. The error follows the approximate rule , which gives a multiplier of 2.3 at and only 0.05 at . Low-ε surfaces are therefore hard to read for true temperature unless the reflected temperature is well known. This agrees with the manufacturer’s statement that when ε is low and the object temperature differs greatly from the reflected temperature, the reflected temperature must be set correctly (Teledyne FLIR, 2019).

Four horizontal stacked bars showing the share of the three radiation paths entering the camera. Clothing: object term 89.1 percent, reflected 3.3, atmosphere 7.6. Paddy water: object 90.9, reflected 1.4, atmosphere 7.7. Weathered tin roof: object 31.7, reflected 58.8, atmosphere 9.5. Foil blanket: object 4.8, reflected 85.2, atmosphere 10.0
Figure 1 Shares of the three radiation paths entering the camera from four surface types on a clear night

Emissivity and reflection

Emissivity (ε) is the fraction that a surface emits relative to a black body at the same temperature. By Kirchhoff’s law, the ability to emit equals the ability to absorb, so an opaque surface that absorbs a fraction reflects the remainder , which is the reason for the reflected term in the measurement equation. The table of Teledyne FLIR (2019) gives the following values (mostly total-spectrum values at 20–32 °C, used as starting values for the 8–14 µm band): human skin about 0.97–0.98 (0.98 at 32 °C), water layers thicker than 0.1 mm 0.95–0.98, dry soil about 0.92, saturated soil about 0.95, black cloth 0.98, oil paints of every colour above 0.9, and aluminium foil about 0.04. Users should remember two groups. Most things that matter for search work in paddy fields (people, water, soil, cloth, plants) have a high ε, above about 0.9, which makes thermal images reliable. Bare metal or foil with a very low ε is the exception that changes the image entirely. This lesson has no figure from a verified source for the ε of straw and rice leaves, so it uses the assumed value 0.95 and the team should measure it themselves with the method in the next section.

ε also depends on the viewing angle. For a smooth surface such as water, the reflectance can be calculated from the complex refractive index of water at that wavelength using the Fresnel equations. At an angle of incidence measured from the normal to the surface, the amplitude coefficients for the two polarisations are and . Unpolarised light reflects , and water that is thick enough is opaque, so . At 10 µm, liquid water at 25 °C has and (Hale and Querry, 1973).

Example 3 Looking at paddy water at different pitch angles

Paddy water is at a true 27 °C (, reflected temperature 8 °C and air 24 °C as before). A camera pointing straight down has an angle of incidence of 0°, while a camera pitched −10° from horizontal has an angle of incidence of 80°. The water surface is assumed to be as smooth as a mirror.

m = 1.218 + 0.0508j                          # liquid water at 10 um (Hale and Querry 1973)
def water_emissivity(theta_deg):
    th = np.radians(theta_deg)
    root = np.sqrt(m**2 - np.sin(th)**2)
    rs = (np.cos(th) - root) / (np.cos(th) + root)
    rp = (m**2 * np.cos(th) - root) / (m**2 * np.cos(th) + root)
    return 1 - (abs(rs)**2 + abs(rp)**2) / 2
T_W = 27.0
print("angle from vertical, camera pitch, emissivity, apparent temperature")
for th in (0, 30, 45, 60, 70, 75, 80, 85):
    eps = water_emissivity(th)
    tot = eps*TAU*band_radiance(T_W) + (1-eps)*TAU*band_radiance(T_REFL) + (1-TAU)*band_radiance(T_ATM)
    print(f"{th:3d} deg  pitch {-(90 - th):4d} deg  eps {eps:.3f}  apparent {to_temp(tot):5.1f} C")
angle from vertical, camera pitch, emissivity, apparent temperature
  0 deg  pitch  -90 deg  eps 0.990  apparent  26.6 C
 30 deg  pitch  -60 deg  eps 0.989  apparent  26.6 C
 45 deg  pitch  -45 deg  eps 0.985  apparent  26.5 C
 60 deg  pitch  -30 deg  eps 0.961  apparent  26.1 C
 70 deg  pitch  -20 deg  eps 0.900  apparent  25.1 C
 75 deg  pitch  -15 deg  eps 0.828  apparent  24.0 C
 80 deg  pitch  -10 deg  eps 0.697  apparent  21.8 C
 85 deg  pitch   -5 deg  eps 0.454  apparent  17.6 C

Down to a pitch of −45° the ε of water is almost constant at 0.985–0.990, and 27 °C water appears as 26.5–26.6 °C. At lower pitch angles, however, ε falls quickly. At −10° it is 0.697 and 27 °C water appears as only 21.8 °C, more than 5 K cooler than the truth. At −5° it is 0.454 and the water appears as 17.6 °C, which is 9 K cooler than when looking straight down. For search work this means that viewing a canal or a flooded paddy plot obliquely from far away makes the water surface look much cooler, and the difference between a person standing at the water’s edge and the water surface will look larger than it really is. A warm object floating on or in the water also has a different contrast with the water surface depending on the viewing angle. These numbers use a single reflected temperature of 8 °C at every angle. In reality the sky near the horizon is warmer than the sky overhead, so the real effect is milder, and a rippled water surface scatters the reflection, so the result lies between the two cases. What can be confirmed is the direction of the effect.

Line chart with two lines against the angle from vertical, from 0 to 85 degrees. The water emissivity line starts at 0.990 at 0 degrees and falls to 0.961 at 60 degrees, 0.697 at 80 degrees and 0.454 at 85 degrees. The apparent temperature line for 27 degrees Celsius water starts at 26.6 and falls to 26.1 at 60 degrees, 21.8 at 80 and 17.6 at 85
Figure 2 Emissivity and apparent temperature of a smooth 27 °C water surface by angle from vertical

How to set ε and the reflected temperature in the field

Two ASTM standards match these two values. ASTM E1862 covers measuring and compensating for the reflected temperature with a radiometric camera, and gives two methods: the reflector method and the direct method. ASTM E1933 covers measuring and compensating for ε, also with two methods, and states that it can be used both in the field and in the laboratory with commonly available materials (ASTM International, 2022a, 2022b). The procedure of Teledyne FLIR (2019) is concrete and a field team can use it immediately:

  1. Measure the apparent reflected temperature first. Crumple a large sheet of aluminium foil, flatten it out and stick it on cardboard. Place it in front of the object with the foil side facing the camera, set ε = 1.0 and the distance to 0, and measure the foil’s apparent temperature. The foil counts as a perfect reflector, so the value obtained equals the apparent reflected temperature of the surroundings. A thermocouple cannot be used instead, because a thermocouple measures temperature, not radiation intensity.
  2. Measure ε. Set the reflected temperature from step 1, then stick electrical tape of known high ε (FLIR uses 0.97) on the surface of interest. Heat the surface uniformly until it is at least 20 K above room temperature, so that there is enough difference from the surroundings, and wait until the tape is at the same temperature as the surface. Read the temperature of the tape using the tape’s ε. Then move the measurement spot to the surface next to the tape and adjust ε until the surface reads the same as the tape. This method assumes that the tape and the surface are at the same temperature, and the tape must be opaque and have a well-known ε.
  3. Record all the settings in the mission log (ε, reflected temperature, distance, humidity, air temperature), so that whoever reads the results knows what the numbers in the image were calculated from.

Images recorded radiometrically (which keep the raw value of every pixel) allow ε and the reflected temperature to be corrected afterwards (Teledyne FLIR, 2019). This matters when you discover only during later analysis that the reflected temperature was not measured correctly. Colour-adjusted 8-bit images cannot be corrected afterwards. Module 10 covers file formats.

Module lab

Lab: measuring ε, reflected temperature and the effect of viewing angle

  1. Run the code of Example 1 with the band changed to 7.5–13.5 µm and then 8–12 µm, and record how much the exponent at 30 °C changes.
  2. Place four materials outdoors: water in a tray, cotton cloth, a tin sheet and foil. Leave them until they reach equilibrium, measure the true temperature with a calibrated contact thermometer, and take thermal images on a clear night and when it is cloudy.
  3. Measure the apparent reflected temperature with crumpled foil, following step 1 in this module, then calculate the true temperature of each surface with the function in Example 2 and compare it with the thermometer.
  4. Set the reflected temperature wrongly by ±5 K and ±10 K in the camera or in software, record the error for each material, and compare it with the rule.
  5. Image the water surface in the tray from pitch angles of −90°, −45°, −20° and −10° (at a constant distance, as far as is practicable indoors or on a tripod) and compare the apparent temperature with Example 3.

Common mistakes

Watch out

  • Thinking the signal varies exactly as . In the 8–14 µm band the exponent is about 4.5 at 30 °C. Using slightly underestimates the sensitivity.
  • Using the camera’s default ε for every material and not checking whether the surface you see is metal or foil.
  • Ignoring the reflected temperature. When a surface has a low ε, the error is magnified by a factor of .
  • Using a thermocouple to find the reflected temperature. It measures temperature, not the radiation intensity the surface reflects.
  • Looking at water at a very oblique angle and believing it is truly cold. At a low pitch angle the water surface reflects more of the sky.
  • Believing that red in the image is a temperature, when an 8-bit image has been range-adjusted and the user does not know how the parameters were set.

Summary

  • The radiation a camera receives in the 8–14 µm band is calculated from Planck’s law by integration. The local exponent is about 4.5, and a 1 K difference at 30 °C changes the radiation by about 1.5%.
  • The signal a camera receives has three terms: object, reflected and atmospheric, . The apparent temperature is the black-body temperature that gives the same total signal.
  • Surfaces with a high ε (people, water, soil, cloth) read close to the truth. Surfaces with a low ε (old tin, foil) show a reflection of the sky, and an error in the reflected temperature is magnified by a factor of .
  • The emissivity of water falls when it is viewed obliquely (0.990 looking straight down, down to 0.697 at a −10° pitch), so the water surface looks cooler depending on the viewing angle.
  • Measure the reflected temperature with crumpled foil, measure ε with tape, and record the settings every time, following the ASTM and manufacturer procedures.

Check your understanding

  1. Using the exponent , a surface warms from 25 °C to 30 °C. About what percentage does the radiation in the camera band increase?
  2. A surface with has its reflected temperature set wrongly by 6 K. About how wrong is the recovered true temperature?
  3. Let , , (in the same units), and . Find .
  4. A camera pitched −15° from horizontal looks at smooth water. What is the angle of incidence on the water, and what ε does the table in Example 3 give?
  5. Why can a thermocouple not be used instead of crumpled foil to measure the apparent reflected temperature?
Answers
  1. , an increase of about 7.8%
  2. K (off by about 6 K)
  3. The angle of incidence is and
  4. A thermocouple measures the temperature of the object it touches, whereas the apparent reflected temperature is the radiation intensity of the surroundings that the surface reflects into the camera (for example a sky much colder than the air). Crumpled foil reflects that radiation into the camera in place of the real surface, so it measures the value we need.

Key formulas

Spectral radiance of a black body (Planck's law)
Radiance in the camera band
Thermal camera measurement equation
Error from a wrongly set reflected temperature (approximate)
Emissivity of a smooth surface by angle of incidence

Key references

  1. Vollmer, M., & Möllmann, K.-P. (2017). Infrared thermal imaging: Fundamentals, research and applications (2nd ed.). Wiley-VCH. link
  2. FLIR Systems, Inc. (2019). Reference documentation: Thermography (Publication No. T810442). Teledyne FLIR. link
  3. National Institute of Standards and Technology. (n.d.). CODATA value: Second radiation constant (2022 CODATA recommended value). The NIST reference on constants, units, and uncertainty. link
  4. Teledyne FLIR. How does emissivity affect thermal imaging? link
  5. ASTM International. (2022b). Standard practice for measuring and compensating for reflected temperature using infrared imaging radiometers (ASTM E1862-14(2022)). ASTM International. link
  6. ASTM International. (2022a). Standard practice for measuring and compensating for emissivity using infrared imaging radiometers (ASTM E1933-14(2022)). ASTM International. link
  7. Hale, G. M., & Querry, M. R. (1973). Optical constants of water in the 200-nm to 200-μm wavelength region. Applied Optics, 12(3), 555–563. link
  8. DJI. Matrice 4 series specs (O4 Enterprise video transmission). link

Further reading

Study the assigned knowledge units in advance, review media and take the module quiz

In class / field

Lab or field practice from worksheets with a safety checklist

Learning evidence: Checked worksheets and quiz results

Module quiz

This is a formative self-check, not a graded exam

Knowledge domain: Inspection, industry and surveillance · Public safety and disasters · Sensors and embedded systems · Mathematics, physics and statistics