Module 9/10 · Weeks 13–14 · 14 h

Image interpretation and detection of persons and heat sources

UAT 455 Sensor, Camera and Thermal Imaging Technology for UAS

About 100 minDraft, awaiting reviewLast updated 24 October 2026

Lesson

By the end of this module you will be able to

  1. Calculate the apparent temperature of a person in different states (dry clothing, wrapped in a blanket, soaked, bare face and hands, foil blanket) against the background, and explain why cold spots and spots with almost no difference must be looked for too
  2. Assess how flying height, canopy and the person's condition set the difference that is left for the image reader, and grade the result as clear, marginal or miss
  3. Screen points of interest with rules on size, difference, movement and context, and record the reasons for rejecting a point
  4. Calculate the mixing of a small hot object in a pixel at the radiance level, compare it with averaging temperatures, and check for saturation of the measurement range
  5. Explain the limits of reading the temperature of a hot spot from a single pixel, and set out a safe procedure for checking a smouldering fire

Prerequisites: Module 6 Thermal radiation, apparent temperature and emissivity · Module 7 Thermal camera operation and settings · Module 8 Environmental effects on thermal images

Why this matters

At 03:30 the camera operator of the Thung Sommuti team had flown all of the dry rice-field sections and had collected four points of interest (H1 to H4) from the thermal images over the night. A little after 05:00 the drone came back to check the line of the canal, a waterside with palm trees along the earth bank, and collected three more (H5 to H7), seven points in all that nobody had yet walked out to look at. The ground team has enough people to check no more than two points before dawn (an assumed case). The questions of this module are therefore two. First, what does a “person” look like in a thermal image in each situation, including the situations where the person does not stand out at all or stands out as a cold spot? Second, how do we choose the points worth a visit so that no time is wasted on false ones, and when we find a very hot source such as an ember, what can the number in a single pixel tell us, and what can it not tell us?

Module 7 taught the settings that stop the difference from vanishing in the image, and Module 8 taught how the environment sets the difference between a person and the background. This module brings those two together to read real images. It does not repeat UAT 460, which teaches the number of pixels on a person, the detection chain and AI screening. All the numbers below use the assumed values and models of Module 8, at the same times and over the same backgrounds.

A person in a thermal image: hot, cold and blended in

What the camera sees is the apparent temperature of each kind of surface, according to the measurement equation of Module 6. A person wears clothing with ε of about 0.95, the skin of the face and hands has ε of about 0.98, and an emergency foil blanket has an ε of only 0.04, so it reflects the cold sky instead of emitting its own heat. A searcher should therefore be prepared for a person to have three appearances: a hot spot (face and hands), a spot that blends into the ground (clothing, especially when the background is water) and a cold spot (foil blanket, metal). The next example calculates everything at 02:00 at a range of 80 m looking straight down ( from Module 8), using the clothing-surface function of Module 8 and the measurement equation of Module 6.

Example 1 Five states of a person against three backgrounds

At 02:00 the backgrounds from the Module 8 model are dry stubble at 16.6 °C, damp paddy soil at 20.4 °C and the surface of paddy water at 26.7 °C. The reflected temperature is 8 °C and the air is at 24 °C. A person has five states: thin clothing at 0.6 clo, clothing wrapped in a blanket at 1.0 clo, clothing soaked through at a humidity of 86%, a bare face and hands (skin at 33 °C, an assumed value, with ε = 0.98), and a foil blanket with ε = 0.04 and an outer surface at 25 °C (assumed). Find the apparent temperature difference from each kind of background.

import math
import numpy as np
H_P, K_B, C_L, C2 = 6.62607015e-34, 1.380649e-23, 299792458.0, 1.438776877e-2
lam = np.linspace(8e-6, 14e-6, 601)                         # camera band 8-14 um
def band_radiance(t_c):                                     # as in Module 6
    t = np.asarray(t_c, dtype=float) + 273.15
    l = 2 * H_P * C_L**2 / lam**5 / (np.exp(C2 / (lam * t[..., None])) - 1)
    return np.trapezoid(l, lam, axis=-1)
grid = np.linspace(-40.0, 700.0, 3701); Lg = band_radiance(grid)
def to_temp(w): return float(np.interp(w, Lg, grid))
GAMMA, TD = 0.0665, 21.5
def esat(t): return 0.6108 * math.exp(17.27 * t / (t + 237.3))
def clothing(ta, tr, clo=0.6, met=0.9, v=0.5, wet=0.0, rh=None):   # outer clothing surface temperature, as in Module 8
    icl = 0.155 * clo
    fcl = 1 + 1.29 * icl if icl <= 0.078 else 1.05 + 0.645 * icl
    tsk = 35.7 - 0.028 * met * 58.15
    ea = esat(ta) * rh / 100 if rh is not None else esat(TD)
    def resid(tcl):
        hc = max(2.38 * abs(tcl - ta) ** 0.25, 12.1 * math.sqrt(v))
        hr = 3.96e-8 * ((tcl + 273) ** 4 - (tr + 273) ** 4) / (tcl - tr) if abs(tcl - tr) > 1e-6 else 4.7
        return (tsk - tcl) / icl - fcl * (hc * (tcl - ta) + hr * (tcl - tr) + wet * hc / GAMMA * (esat(tcl) - ea))
    lo, hi = ta - 20.0, tsk
    for _ in range(80):
        mid = (lo + hi) / 2
        lo, hi = (mid, hi) if resid(mid) > 0 else (lo, mid)
    return (lo + hi) / 2
def rad(eps, t_obj, tau, t_refl=8.0):                       # radiance reaching the camera from the surface, before adding the air term
    return eps * tau * band_radiance(t_obj) + (1 - eps) * tau * band_radiance(t_refl)
def seen(eps, t_obj, tau, t_atm=24.0):
    return to_temp(rad(eps, t_obj, tau) + (1 - tau) * band_radiance(t_atm))
TAU = 0.946                                                 # 80 m at night, from Module 8
BG = {"dry stubble": (0.95, 16.6), "wet soil": (0.95, 20.4), "paddy water": (0.98, 26.7)}   # 02:00, Module 8
TA, TR = 24.0, 16.5                                         # air, and radiant temperature at 02:00
STATES = [("dry clothing, 0.6 clo", 0.95, clothing(TA, TR, 0.6)),
          ("blanket wrapped, 1.0 clo", 0.95, clothing(TA, TR, 1.0)),
          ("soaked clothing, RH 86 %", 0.95, clothing(TA, TR, 0.6, wet=1.0, rh=86)),
          ("bare face and hands (assumed)", 0.98, 33.0),
          ("foil blanket (assumed 25 C)", 0.04, 25.0)]
print("apparent temperature at 80 m, then contrast to each background (K); * marks |contrast| >= 2 K")
print(f"{'':31s}" + "".join(f"{n:>13s}" for n in BG))
print(f"{'background apparent (C)':31s}" + "".join(f"{seen(e, t, TAU):13.1f}" for e, t in BG.values()))
for name, eps, t in STATES:
    a = seen(eps, t, TAU)
    cells = []
    for e, tb in BG.values():
        c = a - seen(e, tb, TAU)
        cells.append(f"{c:+10.1f}{'*' if abs(c) >= 2 else ' '}  ")
    print(f"{name:31s}" + "".join(cells) + f" surface {t:5.1f} C -> apparent {a:5.1f} C")
apparent temperature at 80 m, then contrast to each background (K); * marks |contrast| >= 2 K
                                 dry stubble     wet soil  paddy water
background apparent (C)                 16.6         20.0         26.2
dry clothing, 0.6 clo                +9.5*        +6.0*        -0.1    surface  27.1 C -> apparent  26.1 C
blanket wrapped, 1.0 clo             +8.0*        +4.6*        -1.6    surface  25.5 C -> apparent  24.7 C
soaked clothing, RH 86 %             +7.0*        +3.6*        -2.6*   surface  24.3 C -> apparent  23.6 C
bare face and hands (assumed)       +15.5*       +12.1*        +5.9*   surface  33.0 C -> apparent  32.1 C
foil blanket (assumed 25 C)          -7.0*       -10.4*       -16.6*   surface  25.0 C -> apparent   9.6 C

The result holds three lessons for the image reader. First, when the background is dry stubble, every state of a clothed person stands out, by +7.0 to +9.5 K. Even soaked clothing still stands out (+7.0 K) and does not fall low enough to blend in. Second, when the background is water, clothing does not stand out as a warm spot. Thin clothing differs by only −0.1 K (a miss), the blanket-wrapped state is 1.6 K cooler than the water (marginal), and the soaked state is 2.6 K cooler, which meets the clear threshold numerically (the * in the table) but is a spot that is cooler than the water, so a reader who looks only for bright spots overlooks it. The clothing is cooler than the water because the paddy water at 26.7 °C still holds the heat of the day (Module 8). A bare face and hands are the only signal that stands out over water (+5.9 K), but they are small (a face of about 0.2 m is 2 to 3 pixels at 80 m). Third, a foil blanket is not a warm spot. The foil surface is at 25 °C but the camera sees 9.6 °C, because ε = 0.04 makes almost all of the signal a reflection of the sky (Module 6). Against stubble it is therefore a cold spot at −7.0 K, and against water it is −16.6 K, the largest difference in the table. A searcher who looks only at bright spots will miss a person under foil. In real work the image reader must therefore look for anomalies in both directions, both brighter and darker than the ground, including unnaturally rectangular, shiny metallic outlines.

Bar chart split in two directions around the zero line. Five states of a person, each with two bars: against dry stubble and against paddy water. Dry clothing at 0.6 clo is plus 9.5 and minus 0.1 kelvin. Wrapped in a blanket at 1.0 clo, plus 8.0 and minus 1.6. Soaked, plus 7.0 and minus 2.6. Bare face and hands, plus 15.5 and plus 5.9. Foil blanket, minus 7.0 and minus 16.6
Figure 1 Apparent temperature difference of five states of a person against stubble and water at 80 m at 02:00

Height, canopy and the difference that reaches the image reader

The difference the image reader sees comes from the true difference multiplied by (Module 8) and by the fraction of the person that is visible through the canopy. When one pixel mixes a person and the background, the apparent difference is

where and are the radiance of the person and of the background reaching the camera, is the fraction of the pixel covered by the person (the canopy gap fraction from Module 8 if the person is under trees) and is the conversion from radiance to apparent temperature. The searcher grades the result at three levels: clear when K (matching the target of Perić et al. (2019), who used a difference of 2 K), marginal when it is 1 to 2 K, and miss when it is below 1 K. The three levels are a team convention that must be checked against real image readers in the lab. They are not a standard, because the texture of a real background means that readers need a much larger difference than the instrument’s detection threshold.

Example 2 Five situations at flying heights of 40 to 90 m

Use the atmospheric transmittance from Module 8 at the different slant ranges (interpolated from the table of Example 3 in Module 8). The heights are 40, 60, 80 and 90 m, where 90 m is the ceiling of the general CAAT conditions, which Module 10 will cover. The five situations are as follows. S1 is a person in thin clothing on stubble at 05:00 (clothing surface 26.1 °C, stubble 15.0 °C, from the table of Module 8). S2 is the same person under a canopy at LAI 1.5, viewed obliquely at 45°, with leaves at 21.5 °C (assumed). S3 is a person in thin clothing beside water at 22:00 (27.9 °C against water at 29.2 °C). S4 is a person in soaked clothing on a dry, windy night (humidity 60%, wind 3 m/s) on damp paddy soil at 21.1 °C at 02:00. S5 is a foil blanket on stubble at 02:00.

RANGES = [0, 80, 92, 113, 160, 234]; TAUS = [1.0, 0.946, 0.938, 0.926, 0.904, 0.868]   # night-time transmittance, Module 8
tau_at = lambda r: float(np.interp(r, RANGES, TAUS))
def gap(lai, zen, k0=0.5): return math.exp(-k0 * lai / math.cos(math.radians(zen)))
def contrast(p, bg, height, pitch=90.0, f=1.0):
    """Apparent temperature of the person pixel minus that of a pure background pixel (K). f = fraction of the person that is visible"""
    r = height / math.sin(math.radians(pitch)); tau = tau_at(r)
    w_bg = rad(bg[0], bg[1], tau); w_p = rad(p[0], p[1], tau)
    return to_temp(f * w_p + (1 - f) * w_bg + (1 - tau) * band_radiance(24.0)) - to_temp(w_bg + (1 - tau) * band_radiance(24.0))
soaked3 = clothing(24.0, 16.5, 0.6, 0.9, 3.0, wet=1.0, rh=60)       # soaked, on a drier and windier night (assumed as a worst case)
SCEN = [("S1 open stubble, 05:00", (0.95, 26.1), (0.95, 15.0), 90.0, 1.0),
        ("S2 under canopy LAI 1.5, 05:00, 45 deg", (0.95, 26.1), (0.97, 21.5), 45.0, gap(1.5, 45.0)),
        ("S3 beside paddy water, 22:00", (0.95, 27.9), (0.98, 29.2), 90.0, 1.0),
        ("S4 soaked, dry windy night, wet soil, 02:00", (0.95, soaked3), (0.95, 21.1), 90.0, 1.0),
        ("S5 foil blanket on stubble, 02:00", (0.04, 25.0), (0.95, 16.6), 90.0, 1.0)]
print(f"soaked clothing, 3 m/s, RH 60 %: {soaked3:.1f} C; canopy gap fraction at 45 deg: {gap(1.5, 45.0):.3f}")
print(f"{'':42s}" + "".join(f"{h:>9d} m" for h in (40, 60, 80, 90)))
for name, p, bg, pitch, f in SCEN:
    cs = [contrast(p, bg, h, pitch, f) for h in (40, 60, 80, 90)]
    tags = ["clear" if abs(c) >= 2 else ("marginal" if abs(c) >= 1 else "miss") for c in cs]
    print(f"{name:42s}" + "".join(f"{c:+8.1f}K" for c in cs))
    print(f"{'':42s}" + "".join(f"{t:>10s}" for t in tags))
soaked clothing, 3 m/s, RH 60 %: 20.4 C; canopy gap fraction at 45 deg: 0.346
                                                 40 m       60 m       80 m       90 m
S1 open stubble, 05:00                       +10.3K   +10.2K   +10.0K    +9.9K
                                               clear     clear     clear     clear
S2 under canopy LAI 1.5, 05:00, 45 deg        +1.4K    +1.4K    +1.3K    +1.3K
                                            marginal  marginal  marginal  marginal
S3 beside paddy water, 22:00                  -1.8K    -1.8K    -1.7K    -1.7K
                                            marginal  marginal  marginal  marginal
S4 soaked, dry windy night, wet soil, 02:00    -0.6K    -0.6K    -0.6K    -0.6K
                                                miss      miss      miss      miss
S5 foil blanket on stubble, 02:00             -7.2K    -7.1K    -7.0K    -6.9K
                                               clear     clear     clear     clear

The first conclusion is that a height of 40 to 90 m changes the difference by less than 0.4 K in every situation (for example S1 goes from +10.3 to +9.9 K). The atmosphere is clear over this range (), so the height should be chosen from the number of pixels on the person, as learned in UAT 460, and not from the temperature difference. The difference is set by the situation. The second conclusion is that S1 and S5 are clear at every height (+10.0 and −7.0 K at 80 m). The third is that S2, a person under a thin canopy at LAI 1.5, is left with only +1.3 K out of a true difference of 4.6 K (gap fraction 0.346), which is rated marginal. The fourth is that S3, beside water at 22:00, has the person cooler than the water by −1.7 K. This is marginal, and it is easy to read the wrong way round. The last conclusion is that S4, a soaked person on a dry, windy night over damp soil, is left with −0.6 K, which is rated a miss, even though it is the situation most dangerous for the missing person (wet, cold, windy). The danger to the missing person and the difficulty of detection are therefore often one and the same, which is why the team must use RGB cameras at first light, scent dogs or foot teams in the parts that the thermal image rates as “marginal” or “miss”.

Colour table with five rows and four columns. Apparent temperature difference at heights of 40, 60, 80 and 90 metres. S1 open stubble: plus 10.3, 10.2, 10.0, 9.9 kelvin, green for clear. S2 under canopy: plus 1.4, 1.4, 1.3, 1.3, gold for marginal. S3 beside water: minus 1.8, 1.8, 1.7, 1.7, gold for marginal. S4 soaked on a dry windy night: minus 0.6 at every height, pink for miss. S5 foil blanket: minus 7.2, 7.1, 7.0, 6.9, green for clear
Figure 2 Apparent difference of five situations at different flying heights

Points of interest and false signals

The thermal images of a search in rice fields contain many heat sources that are not people. The next table summarises the common ones and the signs that tell them apart (temperatures are assumed example values, except for engines, which Burke et al. (2019) say can reach about 100 °C after running for a long time, and sunlit metal roofs, for which the Module 8 model gives 62 °C at noon but only 16.7 °C at 02:00).

Source that is often mistakenWhy it looks like a personA useful way to tell them apart
Buffalo or cattle in a penWarm skin, similar sizeLarger (2 to 3 m), a four-legged shape, part of a herd
DogsWarm, movingSmaller (no more than 1 m), moving faster than a walking person
Parked motorcycleThe engine section is very hotThe difference is above the range for a person, and the frame has straight-line shapes
Water pumps and motors in a hutOne intensely hot spotA difference of tens of kelvin, inside a building (the case of Module 7)
Metal roofWarm after sitting in the sunLarge, rectangular, and cools quickly at night
Concrete pipes and earth banksHigh inertia, give back heat slowlyLarge, low, not moving, lined up along the canal
Sky reflection on water and metalAppears as a cold or marginal spotPosition changes with the camera angle

The screening rules that work in the field therefore number four. The first is size (length 1.0 to 2.2 m and width 0.3 to 1.0 m, which covers a person lying, sitting and standing when seen from above). The second is apparent difference (the magnitude of 1 to 12 K, whether brighter or darker than the ground, which covers clothed people on stubble and damp soil in Example 1, +3.6 to +9.5 K, and a foil blanket on stubble, −7.0 K; falling outside the range are thin clothing over water (−0.1 K, below 1 K), bare faces and hands on stubble and damp soil (+15.5 and +12.1 K, above 12 K) and a foil blanket over water (−16.6 K), so these are cases the rule can miss and they must be checked separately). The third is movement (a missing person walks at no more than 1.5 m/s). The fourth is context (where it is and what is near it), which a calculator cannot check and a person must judge.

Example 3 Screening the seven points of interest of tonight

Points H1 to H7 have the size, difference, speed and location given in the code (all values assumed). Apply the first three rules to the table, then look at the context by eye.

# candidates: (id, length m, width m, apparent difference K, speed m/s, context)  (all values assumed)
CANDS = [("H1", 2.4, 0.9, 6.0, 0.0, "paddy bund beside a cattle pen"), ("H2", 1.8, 0.7, 38.0, 0.0, "farm track, parked motorcycle"),
         ("H3", 0.8, 0.8, 55.0, 0.0, "pump shed"), ("H4", 6.0, 4.0, 3.0, 0.0, "tin roof of a field hut"),
         ("H5", 0.7, 0.3, 4.5, 2.2, "canal bank"), ("H6", 1.6, 0.6, 5.2, 0.0, "canal bank under a palm"),
         ("H7", 3.0, 1.0, 2.0, 0.0, "culvert at a track crossing")]
def screen(length, width, dt, speed):
    why = []
    if not (1.0 <= length <= 2.2 and 0.3 <= width <= 1.0): why.append("size")
    if not (1.0 <= abs(dt) <= 12.0): why.append("contrast")
    if speed > 1.5: why.append("speed")
    return why
for cid, l, w, dt, v, ctx in CANDS:
    why = screen(l, w, dt, v)
    print(f"{cid} {l:3.1f} x {w:3.1f} m {dt:5.1f} K {v:3.1f} m/s {ctx:31s} " + ("KEEP -> verify with RGB and the ground team" if not why else "reject: " + ", ".join(why)))
H1 2.4 x 0.9 m   6.0 K 0.0 m/s paddy bund beside a cattle pen  reject: size
H2 1.8 x 0.7 m  38.0 K 0.0 m/s farm track, parked motorcycle   reject: contrast
H3 0.8 x 0.8 m  55.0 K 0.0 m/s pump shed                       reject: size, contrast
H4 6.0 x 4.0 m   3.0 K 0.0 m/s tin roof of a field hut         reject: size
H5 0.7 x 0.3 m   4.5 K 2.2 m/s canal bank                      reject: size, speed
H6 1.6 x 0.6 m   5.2 K 0.0 m/s canal bank under a palm         KEEP -> verify with RGB and the ground team
H7 3.0 x 1.0 m   2.0 K 0.0 m/s culvert at a track crossing     reject: size

The rules reject six points and leave H6 alone. H1 is too large and lies near a cattle pen. H2 has a difference of 38 K, above the range for a person, and lies beside a motorcycle. H3 is small and intensely hot (55 K) and is at a water pump. H4, at 6 × 4 m, is the roof of a hut. H5 is small (0.7 m) and moves at 2.2 m/s, faster than a person walks, so it is a dog or another animal. H7, at 3 m, is a culvert under the track. H6 is 1.6 m long and 0.6 m wide, differs from the ground by 5.2 K, does not move, and lies under a palm beside the canal. It passes every rule, so it is the point handed on for confirmation with RGB and the ground team in Module 10. Three cautions apply. First, these rules reject points in order to set the order of checking, not to conclude that “it is not a person”. A rejected point must have its reason recorded and must not be deleted (following the practice of UAT 460), and a person under a foil blanket over water (−16.6 K, above 12 K) or in thin clothing over water (−0.1 K, below 1 K) can fall outside the 1 to 12 K range. A foil blanket on stubble (−7.0 K) passes the difference rule because the code uses the magnitude of the difference (abs), but the image reader must recognise it as a spot darker than the ground. Second, the size and difference thresholds are assumed values for this case, and the team must adjust them with data from its own lab work. Third, a confused missing person may move faster or slower than expected, so using speed as a cut-off needs a margin.

Diagram of points on a plane of length 0 to 6.5 metres against apparent difference 1 to 100 kelvin on a logarithmic scale. The green frame is the person-like range, length 1.0 to 2.2 metres and difference 1 to 12 kelvin. Point H6 at 1.6 metres and 5.2 kelvin is inside the frame and drawn as a pink circle. The other points are outside the frame: H1 2.4 metres 6.0, H2 1.8 metres 38, H3 0.8 metres 55, H4 6.0 metres 3.0, H5 0.7 metres 4.5 and H7 3.0 metres 2.0
Figure 3 The seven points of interest against the person-like range of length and apparent difference

Embers, smouldering fires and mixing within a pixel

In the early morning the village head reported smoke from a straw pile beside the organic-soil plot near the canal. The team must check whether there is a smouldering fire, which is burning without flame. Burke et al. (2019) explain that smouldering occurs at about 500 to 700 °C, compared with 1,500 to 1,800 °C for a flaming fire, that it uses less oxygen, and that an underground peat fire moves slowly, about 1 cm per hour. Typically an underground peat fire has a peak temperature of about 275 °C (up to 500 °C), and the ground surface above the fire is at 50 to 400 °C according to the literature they cite. In their own experiment, fires buried underground were at 110 to 260 °C and the ground surface above was at about 35 °C when the pit was closed and rose to about 70 °C within an hour (one example image measured 77 °C with the fire inside at 250 °C), while the surrounding ground was at 25 to 30 °C. A thermal camera can therefore detect such a fire even though the eye cannot see it.

The problem is that a small pile of embers seen directly is smaller than a pixel. One pixel at 80 m is 8.09 cm wide (65.4 cm²). An ember 2 cm wide has an area of 4 cm² and fills only 6.1% of the pixel, and the rest is background. The camera therefore reports mixed radiation. Burke et al. (2019) write the mixing as an area-weighted average of temperature, an approximation that works when the differences are small, but radiance is not linear in temperature. The correct mixing is done in radiance and then converted to temperature. The next example compares the two methods using both of the numerical examples from the article of Burke et al., and checks for saturation of the high-gain range (−20 to 150 °C, per the DJI spec) and the low-gain range (0 to 550 °C).

Example 4 A 450 °C ember in a 65.4 cm² pixel, and the ambiguity of the reading

The ember has a surface temperature of 450 °C (assumed, lower than the 500 to 700 °C of the burning zone because the outer surface is cooler) and rests on ground at 30 °C. The camera is 80 m up with a focal length of 11.87 mm. Find the apparent temperature of ember patches 1, 2, 5 and 8 cm wide using the two kinds of mixing, then calculate in how many ways a single reading could arise from different objects. The example assumes that the ember and the ground have the same emissivity and that the camera’s ε and τ settings are correct, so the effects of ε and τ cancel and the displayed temperature equals the pure radiance mixing. If the camera were left at ε = 1 and τ = 1, the displayed values would be lower than the table below.

F_MM = math.hypot(640, 512) * 12e-6 / 2 / math.tan(math.radians(22.5)) * 1000      # focal length from the 45 degree diagonal field of view
GSD = 12e-6 * 80 / (F_MM / 1000); PIX = (GSD * 100) ** 2                               # ground sample distance (m) and pixel area (cm2) at 80 m
T_BG, T_EMBER = 30.0, 450.0
print(f"focal length {F_MM:.2f} mm, GSD {GSD * 100:.2f} cm, pixel area {PIX:.1f} cm2")
print("ember patch (450 C) on 30 C ground: side  fill   radiance blend   temperature blend   high gain (<150 C)?")
for side in (1, 2, 5, 8):
    f = min(1.0, side**2 / PIX)
    a_rad = to_temp(f * band_radiance(T_EMBER) + (1 - f) * band_radiance(T_BG))
    a_lin = (f * (T_EMBER + 273.15) + (1 - f) * (T_BG + 273.15)) - 273.15
    print(f"                                          {side} cm  {f:5.3f}   {a_rad:7.1f} C         {a_lin:7.1f} C          {'saturated' if a_rad > 150 else 'ok'}")
for name, t_hot, f in (("object 35 C, 3/4 pixel, 30 C ground", 35.0, 0.75), ("buried-fire surface 70 C, 3/4 pixel, 30 C ground", 70.0, 0.75)):
    a_rad = to_temp(f * band_radiance(t_hot) + (1 - f) * band_radiance(30.0))
    a_lin = f * (t_hot + 273.15) + (1 - f) * 303.15 - 273.15
    print(f"{name}: radiance blend {a_rad:.1f} C, temperature blend {a_lin:.1f} C")
target = to_temp(4 / PIX * band_radiance(T_EMBER) + (1 - 4 / PIX) * band_radiance(T_BG))   # a 2 cm ember patch (4 cm2)
print(f"one pixel reads {target:.1f} C; the same reading can come from:")
for t_hot in (200.0, 300.0, 450.0, 600.0):
    lo, hi = 0.0, 1.0
    for _ in range(60):
        mid = (lo + hi) / 2
        lo, hi = (mid, hi) if to_temp(mid * band_radiance(t_hot) + (1 - mid) * band_radiance(T_BG)) < target else (lo, mid)
    print(f"  {t_hot:4.0f} C over {100 * lo:5.2f} % of the pixel = {lo * PIX:5.1f} cm2")
focal length 11.87 mm, GSD 8.09 cm, pixel area 65.4 cm2
ember patch (450 C) on 30 C ground: side  fill   radiance blend   temperature blend   high gain (<150 C)?
                                          1 cm  0.015      45.3 C            36.4 C          ok
                                          2 cm  0.061      82.8 C            55.7 C          ok
                                          5 cm  0.382     244.4 C           190.6 C          saturated
                                          8 cm  0.979     443.7 C           441.1 C          saturated
object 35 C, 3/4 pixel, 30 C ground: radiance blend 33.8 C, temperature blend 33.8 C
buried-fire surface 70 C, 3/4 pixel, 30 C ground: radiance blend 61.1 C, temperature blend 60.0 C
one pixel reads 82.8 C; the same reading can come from:
   200 C over 22.15 % of the pixel =  14.5 cm2
   300 C over 11.52 % of the pixel =   7.5 cm2
   450 C over  6.12 % of the pixel =   4.0 cm2
   600 C over  3.98 % of the pixel =   2.6 cm2

The first table shows that an ember 1 cm wide (filling 1.5% of the pixel) reads only 45.3 °C, which is 15 K above the ground and still stands out. But an ember 2 cm wide reads 82.8 °C. Averaging by temperature would give only 55.7 °C, which is wrong by as much as 27 K. The gap between the two methods arises because the radiance of a hot object grows faster than its temperature. For an ember 5 cm wide the computed value is 244.4 °C (if the measuring range were unlimited), above the 150 °C ceiling of high gain, so the camera in high gain is saturated and shows a value that is not the true temperature (the number in the table is what should be read, not what the screen will display). You must switch to low gain (0 to 550 °C) whenever you suspect an intensely hot source. An ember 8 cm wide, which almost fills the pixel (0.979), reads 443.7 °C, close to the true value of 450 °C. The next two lines check the method against the article. An object at 35 °C filling three quarters of a pixel on 30 °C ground gives 33.8 °C by both methods, which matches what Burke et al. (2019) print. An underground-fire surface at 70 °C filling three quarters of a pixel gives 61.1 °C by radiance and 60.0 °C by temperature. The article prints 60 °C, which is a close approximation when the difference is of the order of ten kelvin, but goes astray when the difference is of the order of a hundred kelvin.

The end of the output shows what the decision maker must remember. A pixel reading 82.8 °C cannot tell us whether it is a 450 °C ember of 4.0 cm² (6.1% of the pixel), a 200 °C object of 14.5 cm² (22.2%) or a 600 °C object of 2.6 cm² (4.0%). Any of them is possible. A single-band camera cannot resolve this ambiguity. There are two unknowns (temperature and size) but only one equation, so a second, different measurement is needed, such as another band. This is the idea behind methods for identifying surface temperatures finer than a pixel from satellite images (Dozier, 1981), but the camera used in this course has only one band (8–14 µm). In the field the ambiguity is reduced by flying lower, so that the pixel is smaller and the source fills more of it. At 30 m, for example, a pixel is 3.0 cm wide (9.2 cm²) and an ember 2 cm wide fills as much as 44% of the pixel, after which readings of 150 °C and above are taken with low gain.

There are three practical conclusions. First, a hot spot smaller than a pixel can still be seen clearly even though its temperature cannot be estimated. This agrees with the conclusion of Burke et al. (2019) that a peat fire with a surface at 40 °C or more and 1 m or more wide can be detected from heights of up to 400 m, even with a low-resolution camera. Second, setting an automatic threshold from the top percentile of the image (the article uses the 99th and sets the minimum pixel count according to a size of 10 cm on the ground) works better than setting a threshold in absolute degrees. Third, the false signals that the article identifies are sunlit metal roofs and engines that have run long enough to reach about 100 °C, which can be told apart by shape and location as in the table above.

Safety when checking fires. The DJI specification document (DJI, n.d.) warns against pointing the infrared lens at strong energy sources such as the sun, lava or a laser, because the sensor can be permanently damaged. The team therefore does not fly low over a flaming fire and does not point the camera at the sun. The team does not go in to put out a smouldering fire hidden underground, where there may be sinkholes and toxic gas. It only marks the position, reports it together with the uncertainty (Module 10) and informs the local fire service.

Horizontal bar chart with two bars per group, showing the apparent temperature of a 450 degree ember on 30 degree ground at 80 metres. Ember 1 centimetre wide: radiance mixing 45.3, temperature mixing 36.4. 2 centimetres wide: 82.8 and 55.7. 5 centimetres wide: 244.4 and 190.6. 8 centimetres wide: 443.7 and 441.1. The vertical pink dashed line at 150 degrees is the high-gain ceiling
Figure 4 Apparent temperature of a 450 °C ember on 30 °C ground by patch size at 80 m

Module lab

Lab: making test targets, screening points and measuring mixing in a pixel

  1. Make warm targets in the five states of Example 1, using bags of warm water at about 35 °C wrapped in thin clothing, a thick wrapped blanket, wet clothing (wrung out until just damp), a panel that represents the face and hands (a small warm-water bag with its surface exposed) and a foil blanket. Take thermal images at night on two kinds of ground (dry grass and the surface of shallow water) from two heights. Record the apparent difference and compare it with Examples 1 and 2.
  2. Have at least three image readers who do not know where the targets are look through that set of images and note the points they judge suspicious. Count the targets found and the false points per image, then find the apparent difference at which most readers begin to miss, and compare it with the 1 K and 2 K thresholds of this module.
  3. Photograph ten hot spots around the site (motors, vehicles, roofs, animals and so on, if present and safe), then build a table of size, difference, movement and context as in Example 3. Adjust the thresholds to match the team’s data, and record the reason for rejecting every point.
  4. Use an electric heating pad or a container of hot water with a lid pierced by holes of 2, 5 and 10 cm as the hot source (never real fire). Photograph it from three ranges, then compare the apparent temperature with Example 4. Switch between high gain and low gain when the image saturates.
  5. Write a report sheet for one point of interest in the format of UAT 460, adding two lines: the apparent difference that was read, and what that number still cannot tell us (for example, the size of the heat source).

Safety: the heat source in step 4 can burn the skin. Use heat-resistant gloves and place it on a stable base. Never point the lens at the sun or at a strong energy source. All the work is done on the ground or on a tripod, with no flying needed.

Common mistakes

Watch out

  • Looking only for bright spots: foil blankets, metal, and wet clothing in a strong wind make a person a cold spot or a spot with almost no difference
  • Thinking that flying higher makes the difference vanish: between 40 and 90 m the difference falls by less than 0.4 K. What falls is the number of pixels
  • Treating the screening rules as a verdict: the rules set the order of checking, and a rejected point must have its reason recorded, not be deleted
  • Averaging temperatures in a pixel instead of averaging radiance: for the 2 cm ember the error is as much as 27 K
  • Reading temperatures from a high-gain image when there is an intensely hot source: a value above 150 °C is a saturated value, not the true temperature
  • Believing that the temperature in a single pixel tells the type of fire: the same reading can come from a small, intensely hot ember or from a larger, cooler object
  • Going in to put out an underground fire yourself instead of marking it, reporting it and informing the fire service

Summary

  • A person in a thermal image has three appearances: a hot spot (face and hands), a spot that blends into the ground or is slightly cooler than it (clothing over water, −0.1 to −2.6 K) and a cold spot (foil blanket, −7.0 to −16.6 K). On dry stubble a clothed person stands out by +7.0 to +9.5 K.
  • A height of 40 to 90 m changes the difference by less than 0.4 K. The difference is set by the situation: the background, the canopy (LAI 1.5 leaves +1.3 K), wetness and wind. Grade the result as clear (≥ 2 K), marginal (1–2 K) or miss (< 1 K).
  • The four screening rules, size, difference, movement and context, reject six of the seven points and leave H6, in order to set the order of checking, not to conclude that something is not a person.
  • A pixel mixes radiance, not temperature. A 2 cm ember reads 82.8 °C by radiance, and 55.7 °C if the temperatures are wrongly averaged. A value of 150 °C or more at high gain is a saturated value, and a single pixel cannot separate a small, intensely hot ember from a larger, warmer object.
  • Check a smouldering fire by marking it, reporting it and informing the fire service. Do not fly low over a fire, and do not point the lens at a strong energy source.

Check your understanding

  1. An ember patch 3 cm wide lies in a pixel 6.07 cm wide (the same camera at 60 m). What percentage of the pixel does it fill?
  2. From question 1, if the ember is at 450 °C on 30 °C ground, about how many °C does the pixel read by radiance, and can this value be trusted at high gain (range −20 to 150 °C)?
  3. A point 1.5 m long and 0.5 m wide differs from the ground by 14 K and does not move. Does it pass the rules of Example 3, and what should be done next?
  4. A person in thin clothing beside water has a true difference of 1.1 K (, ). What is the approximate apparent difference, and which level is it?
  5. The surface above an underground fire is at 77 °C, 0.5 × 0.5 m, on ground at 15 °C, at 90 m, where a pixel is 9.1 cm wide. Does this spot completely fill the central pixel, and can it be detected clearly, when the clear threshold is 2 K? (Use , ε = 0.95, reflected temperature 8 °C, air 24 °C and the measurement equation of Module 6.)
Answers
  1. The ember area is cm² and the pixel area is cm², so the fraction is , or 24.4%
  2. Mixing at the radiance level with the same code as Example 4 () gives about 185.5 °C, above the 150 °C ceiling of high gain, so it is saturated and cannot be trusted. Switch to low gain
  3. A length of 1.5 m and a width of 0.5 m pass the size rule. A difference of 14 K is outside the range of 1 to 12 K, so it fails the difference rule, but it should not simply be rejected. Record the reason and check the context, for example whether it is near a vehicle or a motor, or whether it is the exposed face of a person
  4. The apparent difference is K, which is a miss (below 1 K), just short of marginal
  5. A width of 0.5 m equals pixels, so it completely fills the central pixel (). With the measurement equation gives an apparent temperature of about 71.7 °C for the spot and 15.2 °C for the ground, a difference of about 56.5 K, far above the 2 K threshold, so it is clear

Key formulas

Apparent difference of a pixel that mixes a person and the background
Mixing at the radiance level (correct) and at the temperature level (approximate)
Fraction of the pixel that a small object fills

Key references

  1. Perić, D., Livada, B., Perić, M., & Vujić, S. (2019). Thermal imager range: Predictions, expectations, and reality. Sensors, 19(15), 3313. link
  2. Burke, C., Rashman, M., Wich, S., Symons, A., Theron, C., & Longmore, S. (2019). Optimizing observing strategies for monitoring animals using drone-mounted thermal infrared cameras. International Journal of Remote Sensing, 40(2), 439–467. link
  3. Burke, C., Wich, S., Kusin, K., McAree, O., Harrison, M. E., Ripoll, B., Ermiasi, Y., Mulero-Pázmány, M., & Longmore, S. (2019). Thermal-drones as a safe and reliable method for detecting subterranean peat fires. Drones, 3(1), 23. link
  4. DJI. Matrice 4 series specs (O4 Enterprise video transmission). link
  5. Dozier, J. (1981). A method for satellite identification of surface temperature fields of subpixel resolution. Remote Sensing of Environment, 11, 221–229. link

Further reading

Study the assigned knowledge units in advance, review media and take the module quiz

In class / field

Lab or field practice from worksheets with a safety checklist

Learning evidence: Checked worksheets and quiz results

Module quiz

This is a formative self-check, not a graded exam

Knowledge domain: Public safety and disasters