UAT 455 Sensor, Camera and Thermal Imaging Technology for UAS

Worksheet 6 ε, reflected temperature and viewing angle

Lab 6 hAssesses CLO4

Objective

Measure the reflected apparent temperature and ε in the field, retrieve true temperatures with the measurement equation, and see how viewing angle changes a water surface

Equipment and materials

  • Radiometric thermal camera with adjustable ε and reflected temperature
  • Aluminium foil, cardboard and electrical tape
  • Tray of water, cotton cloth, a zinc sheet and foil
  • Calibrated contact thermometer
  • Python and the module 6 example code

Safety

  • Bench or tripod work; no flying
  • Never point the lens at the sun or a strong energy source
  • Sun-heated metal sheets are hot; wear gloves
  • Drink water and rest in the shade when working in the sun

Steps

  1. Run Example 1, change the band to 7.5–13.5 and 8–12 µm, and record the exponent at 30 °C
  2. Leave four materials outdoors to equilibrate, measure true temperatures with the contact thermometer, and image them on a clear night and under cloud
  3. Measure the reflected apparent temperature with crumpled foil as in the lesson, then compute each material's true temperature with the Example 2 function
  4. Set the reflected temperature wrong by ±5 K and ±10 K, record each material's error and compare with the (1 − ε)/ε rule
  5. Image the tray water at pitch −90°, −45°, −20° and −10° and compare with Example 3

Record of results

Table 1 Radiance exponent in three bands at 30 °C
Band (µm)Exponent n at 30 °CRadiance change per 1 K (%)
Table 2 True, read and retrieved temperatures
Material and skyε usedTrue temperature, thermometer (°C)Reflected apparent temperature, foil (°C)Apparent reading (°C)Retrieved temperature (°C)
Table 3 Errors from a wrong reflected temperature, and pitch angle on water
Material or pitchChange made (±5 K, ±10 K or angle)Measured value or error (°C or K)Prediction ((1 − ε)/ε rule or Example 3)

Questions

  1. Why is the exponent n in the camera band larger than 4, and how did it change between bands? What does that say about camera sensitivity?

  2. Which material's retrieved temperature was furthest from the thermometer? Explain using the share of the signal that comes from reflection.

  3. Did the errors from a wrong reflected temperature follow the (1 − ε)/ε rule? Which materials cannot be used for true temperature in practice?

  4. How did the foil and zinc readings differ between the clear night and the cloudy night, and why?

  5. What do your pitch-angle results on water tell you about searching along a canal with distant oblique views?

Check before you hand in

What to hand in

  • Table of exponents for three bands, and a table of true, read and retrieved temperatures
  • Table of errors from a wrong reflected temperature against the rule
  • Graph of ε and apparent water temperature against pitch angle

CLO4 Explain and compute the thermal measurement chain from emission, emissivity and apparent temperature to the camera signal, and choose thermal-camera settings suited to the mission. (CLOs are a web-team draft; the course owner sets the final ones.)

Instructors: answers and teaching notes for this worksheet are in the teaching pack