UAT 459 UAS, Internet of Things and Smart Warehouse Systems
Worksheet 10 A data analysis and security assessment report on the mock system
Objective
Compute MKT, analyse vertical temperature profiles, detect drift with EWMA, and assess zones, SL-T and SL-C under IEC 62443, checking a device against ETSI EN 303 645
Equipment and materials
- Computer with Python, numpy and pandas
- At least one week of mock system data
- Indoor drone with a boom-mounted probe, or a pole that raises the probe
- Vendor documents of the devices the group uses
Safety
- Fly only in an authorised indoor area under instructor supervision, within visual line of sight, with the area cordoned so no one is under the flight path
- Check batteries before flight; store and charge lithium batteries in fire-resistant containers
- If a pole replaces the drone, have a helper steady it and watch for overhead cables
- Do security assessment only from documents and the mock system; never test real systems without written permission
Steps
- Compute MKT as in Example 1 for a normal and an event period, and write a paragraph for QA giving MKT, peak and duration
- Measure two vertical profiles by drone or pole, wait 5τ at each level and analyse as in Example 2
- Simulate 30 days of drifting duty cycle and compare EWMA at λ of 0.1, 0.2 and 0.3 as in Example 3
- Divide the mock system into zones and conduits, set SL-T per FR, rate SL-C, find gaps as in Example 5 and propose compensating countermeasures
- Check one device against the thirteen sections of ETSI EN 303 645 and the six capabilities of NIST IR 8259A
Record of results
| Period | Arithmetic mean (°C) | MKT (°C) | Peak (°C) | Hours above the limit |
|---|---|---|---|---|
| λ | Upper control limit (%) | Day EWMA signals | Day single-value chart signals | Points outside limits in the normal period |
|---|---|---|---|---|
| Zone | SL-T per FR1 to FR7 | SL-C per FR1 to FR7 | FRs with a gap | Compensating countermeasure |
|---|---|---|---|---|
Questions
From Table 1, why is an MKT within 2 to 8 °C not enough to conclude that the product is usable, and which numbers must the QA paragraph contain?
From the vertical profiles you measured (or Example 2 values if you did not fly), what are the top-to-bottom difference and gradient, where is the hot spot, what do you recommend, and why must you wait 5τ at each level?
Which λ signalled first in the group's data, at what cost, and from which period must the target and standard deviation come?
Which zone has the most gaps, what compensating countermeasures do you propose, and what weaknesses did the device check against ETSI EN 303 645 and NIST IR 8259A find that should become procurement criteria next time?
Check before you hand in
What to hand in
- QA summary paragraph
- Profile charts and storage recommendation
- EWMA charts at three λ values
- Zone and conduit diagram, gap table and device check results