Module 5/5 · Weeks 13–15 · 27 h

Integration with automation systems, prototype development and safety

UAT 463 Smart Robotics and Automation

About 100 minDraft, awaiting reviewLast updated 23 October 2026

Lesson

By the end of this module you will be able to

  1. Divide the work among the robot, the PLC and the MES and define the signals they exchange by ISA-95 level
  2. Check the logic of a PLC-robot handshake by exploring every state, and add link supervision
  3. Set an OPC UA subscription (sampling interval, deadband, publishing interval) for a suitable data volume and delay
  4. Calculate the OEE of the cell and link it to engineering decisions
  5. Calculate stopping time and distance and assess the PL of a simple safety function, knowing the scope of ISO 10218, ISO 3691-4 and ISO 13849-1
  6. Plan prototype testing with the number of trials that proves a requirement at a statistical confidence
  7. Check the conditions before a ground robot approaches a drone by exploring every state and failing closed
  8. Separate industrial from service robots by the ISO 8373 definitions and size a fleet from the environment

Prerequisites: UAT 202 Fundamentals of Automation Technology Modules 3 and 5 (PLCs and a sequence as a state machine) · UAT 463 Modules 2 to 4

Why this matters

The MM-1 robot that perceives, decides and controls well is still only one part of the cell. The doors, light curtain, conveyor and charging rack belong to the PLC, the work orders and indicators belong to the MES, and the people who walk into the cell belong to the safety requirements. The most expensive failures seldom happen inside the robot’s algorithms. They happen at the seams between these systems: a handshake signal stuck in a state it should not be in, or a measurement that nobody proved meets its requirement.

This module closes the course with three topics: connecting the robot to the factory’s automation, the safety of the cell (to the level a robotics engineer must know in order to work with safety specialists, not to replace them), and the process of developing and testing a prototype. UAT 202 taught writing PLC logic and viewing a sequence as a state machine. We do not write logic here; we check whether the agreements between systems are correct. All numbers are assumed, and for the standards cited, the detailed content must always be read from the real edition.

The integration architecture of the cell

ISA-95 (ANSI/ISA-95, IEC 62264) organises the functions between the control level and the enterprise level; Part 1 gives models and terminology and Part 3 gives the activity models of manufacturing operations management, usually drawn as levels 0 to 4. In our cell, levels 0 and 1 are the drones, batteries, charging rack, and the sensors and drives. Level 2 is the PLC that runs the conveyor, door and light curtain, together with the controllers of MM-1. Level 3 is the MES that issues battery-swap work orders and computes the indicators, and level 4 is the plant’s planning system. At each seam you must state who sends what, in which format, how often, and who owns the decision (see the systems-engineering knowledge unit, and UAT 459 Module 9 on connecting to warehouse systems).

Three kinds of link are used in this cell. Inside MM-1, ROS 2 and the buses of module 4. Between MM-1 and the PLC, handshake signals that need low delay and clear logic (direct I/O, Modbus or OPC UA). Between the PLC or robot and the MES, OPC UA, a unified architecture for exchanging industrial data (IEC 62541). The companion specification OPC UA for Robotics Part 1 (OPC 40010-1) defines an information model of a “motion device system” covering industrial and mobile robots, so higher-level systems can supervise, monitor condition, manage assets and operate remotely, for example uploading and starting programs (Figure 1).

The most important point about integration is that safety functions, such as emergency stop and detecting a person entering the zone, must be implemented with devices and logic that have a performance level (see the safety section), not with ROS 2 messages or ordinary handshake signals. The handshake we check in example 1 is coordination of production.

Diagram of system layers. The bottom level is field devices: drones, charging rack, sensors and drives. The next level is the PLC, which runs the conveyor, door and light curtain, beside the MM-1 robot running ROS 2. Level three is the MES, which issues work orders and computes indicators, and level four is the plant planning system. The link between the PLC and the robot is handshake signals, and the links from the PLC and the robot to the MES are OPC UA. The safety function is a separate hard-wired loop from the light curtain and emergency stop button to a safety relay
Figure 1 System levels in the cell and the kind of link at each seam

PLC-robot handshake: check every reachable state

Suppose MM-1 must ask the PLC for permission before entering the pick area, and the PLC grants it while the door is closed. Plausible-sounding logic hides holes. For example, if the PLC grants permission and holds it (latched) until the robot finishes, a person who opens the door in the meantime does not stop the robot. A few manual trials will not find it because it needs a precise timing. A more systematic way is simple model checking: build a state model of both sides, let the environment open and close the door or freeze the link at every step, and explore every reachable state by breadth-first search (BFS) looking for states that violate a condition. If none is found, that proves that in the model it cannot happen, and if one is found you get the shortest counterexample to fix.

Example 1 Three versions of the handshake

The latched version grants permission and holds it until the robot finishes. The level version withdraws permission when the door opens, and the robot stops when it does not see permission. The watchdog version adds a count of whether the PLC’s alive signal is frozen, and the robot stops when it has been frozen for 2 steps. Each step is 10 ms. The forbidden condition is the robot moving with the door open for more than 2 steps. The model is small and assumed.

from collections import deque

# a model of the PLC-robot handshake, then check every reachable state (BFS)
# every step (10 ms) the environment may toggle the door and (if enabled) freeze the signal link
STEPS_TO_FINISH, BUDGET, WATCHDOG = 3, 2, 2        # steps to finish a move, most steps the door may stay open while the robot moves, steps a frozen link is tolerated

def step(s, protocol, door_toggle, frozen):
    plc, robot, prog, door, grant, hb, seen_grant, seen_hb, stale, expo = s
    door ^= door_toggle                                                    # a person opens or closes the light-curtain door
    request = robot in ("REQ", "MOVING")
    # PLC: grant when the robot asks and the door is closed
    if plc == "WAIT" and request and not door: plc, grant = "GRANTED", 1
    elif plc == "GRANTED":
        if not request: plc, grant = "WAIT", 0
        elif protocol != "latched" and door: plc, grant = "WAIT", 0            # the latched version never withdraws the grant
    hb = (hb + 1) % 8
    # the robot sees the PLC outputs of the previous step; a frozen link shows old values
    g_now, h_now = (seen_grant, seen_hb) if frozen else (s[4], s[5])
    stale = min(stale + 1, WATCHDOG + 1) if h_now == seen_hb else 0
    seen_grant, seen_hb = g_now, h_now
    if robot == "IDLE": robot, prog = "REQ", 0
    elif robot == "REQ" and seen_grant: robot = "MOVING"
    elif robot == "MOVING":
        stop = (protocol != "latched" and not seen_grant) or (protocol == "watchdog" and stale >= WATCHDOG)
        if stop: robot = "IDLE"
        else:
            prog += 1
            if prog >= STEPS_TO_FINISH: robot = "IDLE"
    expo = expo + 1 if (robot == "MOVING" and door) else 0
    return (plc, robot, prog, door, grant, hb, seen_grant, seen_hb, stale, min(expo, BUDGET + 1))

def explore(protocol, link_faults):
    start = ("WAIT", "IDLE", 0, 0, 0, 0, 0, 0, 0, 0)
    seen, todo, unsafe, parent = {start}, deque([start]), 0, {start: None}
    first_bad = None
    while todo:
        s = todo.popleft()
        for toggle in (0, 1):
            for frozen in ((0, 1) if link_faults else (0,)):
                n = step(s, protocol, toggle, frozen)
                if n not in seen:
                    seen.add(n); todo.append(n); parent[n] = (s, toggle, frozen)
                    if n[9] > BUDGET:
                        unsafe += 1; first_bad = first_bad or n
    return len(seen), unsafe, first_bad, parent

print("protocol         | link faults | reachable states | unsafe states (door open longer than %d steps while moving)" % BUDGET)
for protocol in ("latched", "level", "watchdog"):
    for faults in (False, True):
        n, bad, first_bad, parent = explore(protocol, faults)
        print("%-16s | %-11s | %16d | %d" % (protocol, "yes" if faults else "no", n, bad))

# the shortest counterexample for the level protocol when the link can freeze
n, bad, first_bad, parent = explore("level", True)
path, s = [], first_bad
while parent[s]: path.append((parent[s][1], parent[s][2], s)); s = parent[s][0]
print("counterexample for 'level' with link faults:")
for k, (toggle, frozen, st) in enumerate(reversed(path), 1):
    print("  step %d: door %s, link %s -> robot %s, door %s, grant seen by robot %d" % (k, "toggles" if toggle else "unchanged", "frozen" if frozen else "fresh", st[1], "open" if st[3] else "closed", st[6]))
protocol         | link faults | reachable states | unsafe states (door open longer than 2 steps while moving)
latched          | no          |              123 | 8
latched          | yes         |             1789 | 128
level            | no          |              155 | 0
level            | yes         |             1421 | 72
watchdog         | no          |              155 | 0
watchdog         | yes         |              917 | 0
counterexample for 'level' with link faults:
  step 1: door unchanged, link fresh -> robot REQ, door closed, grant seen by robot 0
  step 2: door unchanged, link fresh -> robot REQ, door closed, grant seen by robot 0
  step 3: door toggles, link fresh -> robot MOVING, door open, grant seen by robot 1
  step 4: door unchanged, link frozen -> robot MOVING, door open, grant seen by robot 1
  step 5: door unchanged, link frozen -> robot MOVING, door open, grant seen by robot 1

The latched version has 8 violating states even with a healthy link and 128 when the link can freeze. The level version fixes the healthy-link case (155 states, no violation found), but with a freezable link 72 states still violate. The shortest counterexample reads as a story. Within 5 steps the robot requests permission, the door opens in exactly the step when the robot starts to move (the robot sees a permission that has not yet been withdrawn), and then the link freezes, so the robot keeps seeing the old permission and moves for 3 steps with the door open, more than allowed. The watchdog version finds no violation in either case (917 states when the link can freeze), because the robot stops by itself when the alive signal does not change. Three points matter. First, the problem comes from overlapping timing, which hand testing misses. Second, the result holds only for the model, so you must also test on the real system (for example hardware-in-the-loop). Third, this handshake is not a safety function: even if it passes the check, it does not replace the light curtain and the safety relay.

Horizontal bar chart of the number of violating states for six handshake cases. The latched version has 8 with a healthy link and 128 with a freezable link. The level version has 0 with a healthy link and 72 with a freezable link. The watchdog version has 0 in both
Figure 2 Number of states violating the condition for three handshake versions

OPC UA: supervisory data and data volume

OPC UA lets a client create a subscription containing one MonitoredItem per variable of interest. Each MonitoredItem has four primary parameters: the sampling interval, the monitoring mode, the filter and the queue (OPC 10000-4 Section 5.13.1). The server samples at the sampling interval, queues only what passes the filter, and the subscription sends messages (NotificationMessage) in cycles of the publishing interval. The DataChangeFilter has an absolute deadband: a notification is generated when the absolute value of (the last value pushed to the queue minus the current value) is greater than the deadband (Section 7.22.2). The value the consumer holds is therefore, by definition, off by no more than the deadband.

OPC UA suits supervisory data such as states, counters and temperatures, not millisecond control, which is the job of ROS 2 and the buses in modules 3 and 4.

Example 2 Data volume of two tags as the deadband changes

A belt speed tag (0.20 m/s with a slow swing and 1.5 mm/s noise) and a joint motor temperature tag (40 to 65 degrees Celsius warming slowly), sampled every 100 ms for 10 minutes (simulated data). Try several deadbands, counting notifications per minute, the largest error the consumer sees, and the data volume, assuming one notification weighs 24 bytes, one message 90 bytes, and a 1 s publishing interval.

import numpy as np

# OPC UA: a MonitoredItem samples every sampling interval and queues a Notification when the value differs from the last queued value by more than the AbsoluteDeadband
rng = np.random.default_rng(12)
dt, T = 0.1, 600.0                                              # sample every 100 ms for 10 minutes
t = np.arange(0, T, dt)
speed = 0.200 + 0.010 * np.sin(2 * np.pi * t / 300) + rng.normal(0, 0.0015, len(t))    # belt speed m/s with noise
temp = 40 + 25 * (1 - np.exp(-t / 400)) + rng.normal(0, 0.05, len(t))                 # joint motor temperature degC warming slowly

def notifications(x, deadband):
    last, sent, err = x[0], [0], 0.0                            # the first value is always sent
    for k in range(1, len(x)):
        if abs(x[k] - last) > deadband: last = x[k]; sent.append(k)
        err = max(err, abs(x[k] - last))                        # the error in the value the consumer holds
    return len(sent), err

BYTES_PER_NOTIFICATION, BYTES_PER_MESSAGE = 24, 90               # rough sizes (assumed)
print("tag   | deadband | notifications per min | max error seen by the consumer | traffic kB/min")
for name, x, dbs in (("speed", speed, (0.0, 0.001, 0.003, 0.010)), ("temp", temp, (0.0, 0.1, 0.5, 1.0))):
    for db in dbs:
        n, err = notifications(x, db)
        per_min = n / (T / 60)
        msgs = min(per_min, 60.0)                               # at most one message per second at a 1 s publishing interval
        print("%-5s | %8.3f | %21.1f | %30.4f | %14.2f" % (name, db, per_min, err, (per_min * BYTES_PER_NOTIFICATION + msgs * BYTES_PER_MESSAGE) / 1000))

# the mean extra delay from the publishing interval (a queued value waits for the next cycle)
for pub in (0.1, 0.5, 1.0, 5.0):
    print("publishing interval %.1f s: mean extra delay %.2f s, worst %.1f s, belt moves %.0f mm during the worst delay" % (pub, pub / 2, pub, 0.2 * pub * 1000))
tag   | deadband | notifications per min | max error seen by the consumer | traffic kB/min
speed |    0.000 |                 600.0 |                         0.0000 |          19.80
speed |    0.001 |                 377.3 |                         0.0010 |          14.46
speed |    0.003 |                  92.8 |                         0.0030 |           7.63
speed |    0.010 |                   0.9 |                         0.0100 |           0.10
temp  |    0.000 |                 600.0 |                         0.0000 |          19.80
temp  |    0.100 |                 100.6 |                         0.1000 |           7.81
temp  |    0.500 |                   3.8 |                         0.5000 |           0.43
temp  |    1.000 |                   1.9 |                         0.9981 |           0.22
publishing interval 0.1 s: mean extra delay 0.05 s, worst 0.1 s, belt moves 20 mm during the worst delay
publishing interval 0.5 s: mean extra delay 0.25 s, worst 0.5 s, belt moves 100 mm during the worst delay
publishing interval 1.0 s: mean extra delay 0.50 s, worst 1.0 s, belt moves 200 mm during the worst delay
publishing interval 5.0 s: mean extra delay 2.50 s, worst 5.0 s, belt moves 1000 mm during the worst delay

With no deadband both tags notify 600 times a minute (every sample, because of noise), using 19.8 kB per minute per tag. Just setting the speed deadband to 0.003 m/s (about twice the noise) cuts notifications to 92.8 a minute, the data to 7.6 kB a minute, and the largest error the MES sees is 0.003 m/s, as set. At 0.010 m/s notifications almost vanish (0.9 a minute), but the MES could see the belt speed off by up to 10 mm/s, which may be too much for the time-compensation calculation of module 1. The temperature tolerates 0.5 degrees at 3.8 notifications a minute. The deadband is thus a decision about the accuracy needed, not just a way to cut data. A 1 s publishing interval makes the data on average 0.5 s old and up to 1 s old, in which the belt moves 200 mm, so this data must never be used for picking, which uses the direct sensors of module 1.

Horizontal bar chart of notifications per minute for the belt speed tag against deadband. At 0 it is 600, at 0.001 it is 377.3, at 0.003 it is 92.8 and at 0.010 it is 0.9
Figure 3 Notifications per minute of the belt speed tag by deadband

MES indicators: the OEE of the cell

The MES does not need to know how many turns a motor made; it needs production indicators. ISO 22400-2 defines key indicators for manufacturing operations management, and one of the most used is OEE, the product of availability (actual production time APT divided by planned busy time PBT), effectiveness (planned run time per item PRI times the quantity produced PQ divided by APT) and the quality ratio QR (good quantity GQ divided by produced quantity PQ). Kang et al. (2016) summarise these definitions from the ISO 22400 series and note that the QR of ISO 22400-2 does not count reworked parts as good, while the quality buy rate (QBR) that they also define does. The exact definitions a plant uses must follow the edition of the standard and the site’s agreement. This lesson uses QR, which does not count reworked parts.

Example 3 The OEE of the cell for each choice of retry count

Take the success probability and mean time of a battery swap from the module 2 example (1 to 4 retries) and simulate 500 shifts of 8 hours. Planned busy time PBT = 28,800 s, designed time per item PRI = 14.0 s, one failure needs a person to recover it for 120 s which is not counted as production time, and 98.5% of the produced items pass the battery seating check (assumed).

# ISO 22400-2 style KPIs a MES computes per shift: A = APT/PBT, E = PRI x PQ / APT, QR = GQ/PQ, OEE = A x E x QR (Kang et al., 2016)
PBT = 8 * 3600.0                          # planned busy time of one shift, s
PRI = 14.0                                # designed time per battery swap, s
RECOVER, RECHECK = 120.0, 0.985           # recovery per failure, s (module 2) and share passing the seating check (assumed)

def shift(p, t_attempt, rng):
    clock = apt = 0.0; produced = good = 0
    while True:
        if clock + t_attempt > PBT: break
        clock += t_attempt; apt += t_attempt
        if rng.random() < p:
            produced += 1; good += rng.random() < RECHECK
        else:
            if clock + RECOVER > PBT: clock = PBT; break
            clock += RECOVER                                     # a person recovers it: not production time
    A, E, Q = apt / PBT, PRI * produced / apt, good / max(produced, 1)
    return A, E, Q, A * E * Q, good

rng = np.random.default_rng(21)
print("retries | p(success) | attempt s | A     | E     | QR    | OEE   | OEE 5-95% over 500 shifts | good swaps per shift")
for r, p, t in ((1, 0.6948, 14.05), (2, 0.8949, 15.96), (3, 0.9242, 16.25), (4, 0.9282, 16.29)):
    runs = np.array([shift(p, t, rng) for _ in range(500)])
    m = runs.mean(axis=0); lo, hi = np.percentile(runs[:, 3], [5, 95])
    print("%7d | %10.4f | %9.2f | %5.3f | %5.3f | %5.3f | %5.3f | %12.3f to %5.3f | %20.0f" % (r, p, t, *m[:4], lo, hi, m[4]))
retries | p(success) | attempt s | A     | E     | QR    | OEE   | OEE 5-95% over 500 shifts | good swaps per shift
      1 |     0.6948 |     14.05 | 0.277 | 0.690 | 0.985 | 0.188 |        0.167 to 0.212 |                  387
      2 |     0.8949 |     15.96 | 0.560 | 0.785 | 0.985 | 0.433 |        0.396 to 0.472 |                  891
      3 |     0.9242 |     16.25 | 0.641 | 0.796 | 0.985 | 0.503 |        0.466 to 0.542 |                 1034
      4 |     0.9282 |     16.29 | 0.656 | 0.798 | 0.985 | 0.515 |        0.478 to 0.551 |                 1060

The numbers show how much the module 2 decision on retries affects output. With 1 retry the mean OEE is only 0.188 (availability 0.277, since almost three quarters of the shift is lost to recovery). With 3 retries OEE rises to 0.503 and good swaps per shift go from 387 to 1,034. The fourth retry adds only 0.012 to OEE, which fits the team’s choice of 3. The 5 to 95% range of OEE per shift at 3 retries is 0.466 to 0.542, so shift-to-shift variation is visible. Raising OEE further needs fewer failures at the cause, for example the perception error of module 1 and knowing the parcel mass in module 3, not just more retries. The MES receives this data over OPC UA as the PQ and GQ counters and machine states.

Safety of the cell: scope of the standards and first calculations

A robot that works near people must go through a risk assessment and be designed to standards. The main standards for this cell are as follows (checked on the ISO catalogue pages). ISO 10218-1:2025 (Part 1, industrial robots) and ISO 10218-2:2025 (Part 2, robot applications and robot cells) are the editions revised in February 2025, replacing the 2011 edition. The key point to know is that the scope of both parts states that they do not cover mobility when robots or manipulators are fixed to or part of driverless industrial trucks or mobile platforms. So the arm of MM-1 falls under ISO 10218, but the mobility of the base must be handled by another standard: ISO 3691-4:2023 (edition 2, June 2023), which gives safety requirements and verification for driverless industrial trucks and their systems, covering what are called AGVs and AMRs. The ISO catalogue says this edition is expected to be replaced by a draft edition, so check the edition in force before use. For people working directly with a robot, the requirements for collaborative applications that used to sit in the supplementary ISO/TS 15066:2016 are now part of the 2025 editions of ISO 10218-1 and ISO 10218-2 (ISO lists ISO/TS 15066 itself as to be revised), and the positioning of safeguards against the approach speed of the body is in ISO 13855:2024 (edition 3, November 2024). The design of safety-related parts of control systems uses ISO 13849-1:2023 (edition 4), which defines performance levels (PL) a to e by the probability of dangerous failure per hour (PFHd). These standards do not say which safety function needs which PL; the user must assess the risk.

At the level a robotics engineer must calculate, there are two things. The first is stopping time and distance. A protective function has a time chain: the sensor detects, the safety PLC processes, and the drive removes power before the robot even starts to slow. The stopping distance is , and the detection range must be longer than this plus a margin (the position error of module 1, intrusion). The method and constants that the standards prescribe (for example the speed at which a person approaches, found in ISO 13855) must be taken from the real edition; the example below shows only the structure of the calculation. The second is the PL of a function. The PFHd of a function made of subsystems in series is the sum of the PFHd of each subsystem, and the overall PL is capped by the subsystem with the lowest PL (the PFHd range of each PL was checked against the Keyence page and the WSPS slides, which cite the standard’s tables). Besides PFHd, the standard also needs a category structure, diagnostics and protection against common-cause failure, which the example does not cover.

Example 4 Stopping distance of MM-1 and the PL of a light-curtain function

The time chain (assumed) is a sensor at 80 ms, two PLC cycles of 10 ms each and a drive at 50 ms, a braking deceleration of 1.0 m/s² and a margin of 0.150 m. Calculate the detection range needed at several speeds. Then assess the PL of the function “light curtain broken, then stop”, which requires PL d (assumed), for three sets of devices (assumed PFHd values; real ones are in the manufacturers’ data sheets).

# time chain of a protective stop: sensor detects -> safety PLC -> drive removes power -> the robot is at rest
# all values are assumed; real ones come from manufacturer data and the method of the standard
t_sensor, t_plc, t_drive = 0.080, 2 * 0.010, 0.050                 # sensor response, two PLC cycles and the drive, s
decel, margin = 1.0, 0.150                                         # braking deceleration m/s^2 and margin (position uncertainty and intrusion) m
print("speed m/s | reaction s | stopping time s | stopping distance m | detection range needed m")
for v in (0.25, 0.5, 1.0, 1.5):
    react = t_sensor + t_plc + t_drive
    stop_t = react + v / decel
    stop_d = v * react + v * v / (2 * decel)
    print("%9.2f | %10.3f | %15.3f | %19.3f | %24.3f" % (v, react, stop_t, stop_d, stop_d + margin))

# the PFHd of a safety function is the sum over subsystems in series, and PL is capped by the weakest subsystem PL
BANDS = [("e", 1e-8, 1e-7), ("d", 1e-7, 1e-6), ("c", 1e-6, 3e-6), ("b", 3e-6, 1e-5), ("a", 1e-5, 1e-4)]
RANK = {"-": 0, "a": 1, "b": 2, "c": 3, "d": 4, "e": 5}
def pl_of(pfh):                                                    # below 1e-8 counts as PL e (the table's top), above 1e-4 is below PL a
    if pfh < 1e-8: return "e"
    return next((pl for pl, lo, hi in BANDS if lo <= pfh < hi), "-")
def evaluate(name, subsystems, required):
    total = sum(p for _, p in subsystems)
    weakest = min((pl_of(p) for _, p in subsystems), key=RANK.get)
    overall = min(pl_of(total), weakest, key=RANK.get)
    print("%-26s PFHd %.2e /h -> PL %s from the sum, weakest subsystem PL %s, required PL %s: %s" % (name, total, pl_of(total), weakest, required, "OK" if RANK[overall] >= RANK[required] else "NOT MET"))
    return total

curtain, logic, sto = ("light curtain", 8.0e-9), ("safety PLC", 1.5e-8), ("drive STO", 2.3e-8)       # assumed values
total = evaluate("A: all components PL e", [curtain, logic, sto], "d")
evaluate("B: cheap sensor 3.0e-7", [("sensor", 3.0e-7), logic, sto], "d")
evaluate("C: cheap sensor + contactor", [("sensor", 3.0e-7), logic, ("contactor", 9.0e-7)], "d")
print("dangerous-failure chance of A per year (2920 operating hours): %.1e" % (total * 2920))
speed m/s | reaction s | stopping time s | stopping distance m | detection range needed m
     0.25 |      0.150 |           0.400 |               0.069 |                    0.219
     0.50 |      0.150 |           0.650 |               0.200 |                    0.350
     1.00 |      0.150 |           1.150 |               0.650 |                    0.800
     1.50 |      0.150 |           1.650 |               1.350 |                    1.500
A: all components PL e     PFHd 4.60e-08 /h -> PL e from the sum, weakest subsystem PL e, required PL d: OK
B: cheap sensor 3.0e-7     PFHd 3.38e-07 /h -> PL d from the sum, weakest subsystem PL d, required PL d: OK
C: cheap sensor + contactor PFHd 1.22e-06 /h -> PL c from the sum, weakest subsystem PL d, required PL d: NOT MET
dangerous-failure chance of A per year (2920 operating hours): 1.3e-04

A reaction time of 0.150 s at 0.5 m/s gives a stopping distance of 0.200 m and a needed detection range of 0.350 m. At 1.0 m/s these are 0.650 m and 0.800 m, and at 1.5 m/s the range must be 1.500 m, because the growing part is , which grows with the square of the speed. Slowing down when a person is near therefore cuts the needed range a great deal. On PL, set A, with every part at level e, has a total PFHd of per hour, giving PL e, above the requirement. Set B uses a cheaper sensor, total PFHd , giving PL d, a pass by exactly one level. Set C, which adds a contactor of 9.0 × 10⁻⁷, has a total PFHd of and falls to PL c: it fails, even though each part is PL d. The conclusion is that sums erode PL, and one weak part can fail the whole function. The speed of the arm and base must also be monitored reliably, separate from the working controller, because module 3 showed that a limit inside the controller is not a protection.

Prototype development and proving that it meets the requirements

A good robot prototype does not come from trying until it works but from a clear cycle. Start from user needs, turn them into testable requirements (ISO/IEC/IEEE 29148), design the architecture and interfaces, build, test level by level from components to system, and check back against the needs. Alongside the deeper design are the test plans of the higher levels (often drawn as a V). The NASA Systems Engineering Handbook defines verification as a formal process that uses test, analysis, inspection or demonstration to confirm that a system and its components satisfy all specified requirements, and it calls for bidirectional traceability between requirements and what verifies them (Appendix D gives an example requirements verification matrix). Technology readiness levels (TRL) tell you where a prototype stands. NASA describes TRL 4 as several components tested together, TRL 5 as a breadboard tested in a near-realistic environment, and TRL 6 as a fully functional prototype. The prototype of this course sits at about TRL 4 to 5.

Requirements of the cell (assumed), traced to the modules and to a way of verifying them:

IDRequirementSourceVerification
R1Battery-swap success rate ≥ 0.90 at 90% confidenceModule 2Test (example 5)
R2Hand error at the battery bay ≤ 3 mm per axisModule 1Test with TRE at independent points
R3Protective field longer than the stopping distance plus marginModule 5Measure real stopping time and distance
R4The handshake never lets the robot move with the door open for more than 2 stepsModule 5Model check and HIL test
R5The 1 kHz control loop is not blockedModule 4Measure timer timing

A requirement proved statistically needs enough test trials planned. To prove that the success rate is at least at confidence , a test with no failures needs trials. If some failures are allowed, use the one-sided Clopper-Pearson (1934) lower bound , where is the number of successes and is the quantile of the beta distribution, the method UAT 461 used for navigation tests.

Example 5 How many battery swaps must be tested to prove R1

Requirement R1 is a success rate of at least 0.90 at 90% confidence. The module 2 model predicts a true rate of 0.9242 (3 retries). Find the number of trials, the failures allowed, and the chance that the test passes if the true rate equals the prediction or is lower (0.89).

import numpy as np
from scipy.stats import beta, binom

# acceptance requirement (assumed): the swap success rate is at least 0.90 at 90% confidence (one-sided Clopper-Pearson lower bound)
R_REQ, CONF = 0.90, 0.90
def lower_bound(successes, n, conf=CONF):
    return 0.0 if successes == 0 else beta.ppf(1 - conf, successes, n - successes + 1)

def max_failures(n):
    # the most failures that still prove the requirement (the bound grows with successes, so bisect)
    if lower_bound(n, n) < R_REQ: return -1
    lo, hi = 0, n
    while lo < hi:
        mid = (lo + hi + 1) // 2
        if lower_bound(n - mid, n) >= R_REQ: lo = mid
        else: hi = mid - 1
    return lo

n0 = np.log(1 - CONF) / np.log(R_REQ)
print("zero-failure demonstration needs n = ln(1-C)/ln(R) = %.2f, so %d trials with no failure" % (n0, int(np.ceil(n0))))
p_design = 0.9242                                              # the module 2 prediction (3 retries)
print("trials n | most failures allowed k | pass chance if the true rate is %.4f | pass chance if it is 0.89" % p_design)
for n in (22, 40, 60, 100, 150, 200, 300):
    k = max_failures(n)
    print("%8d | %23d | %37.3f | %.3f" % (n, k, binom.cdf(k, n, 1 - p_design), binom.cdf(k, n, 0.11)))
need = next(n for n in range(22, 2000) if binom.cdf(max_failures(n), n, 1 - p_design) >= 0.8)
print("smallest n whose test passes with 80%% chance when the true rate is %.4f: %d (failures allowed %d)" % (p_design, need, max_failures(need)))

# the result of a first test round: 60 swaps, 4 failures
s, n = 56, 60
print("first round %d/%d = %.3f, one-sided 90%% lower bound %.3f: requirement %s" % (s, n, s / n, lower_bound(s, n), "shown" if lower_bound(s, n) >= R_REQ else "not shown yet"))
zero-failure demonstration needs n = ln(1-C)/ln(R) = 21.85, so 22 trials with no failure
trials n | most failures allowed k | pass chance if the true rate is 0.9242 | pass chance if it is 0.89
      22 |                       0 |                                 0.177 | 0.077
      40 |                       1 |                                 0.183 | 0.056
      60 |                       2 |                                 0.157 | 0.033
     100 |                       5 |                                 0.222 | 0.030
     150 |                       9 |                                 0.292 | 0.027
     200 |                      14 |                                 0.445 | 0.039
     300 |                      22 |                                 0.491 | 0.022
smallest n whose test passes with 80% chance when the true rate is 0.9242: 620 (failures allowed 52)
first round 56/60 = 0.933, one-sided 90% lower bound 0.871: requirement not shown yet

A test with no failures needs 22 trials, but if the true rate is 0.9242 the chance that 22 trials have no miss is only 17.7%, because the requirement is set close to the predicted value (only 2.4 percentage points away). The result is surprising: more trials do not raise the chance of passing quickly. At 100 trials 5 failures are allowed but the chance of passing is only 22.2%; at 300 trials it is 49.1%, and it takes 620 trials (52 failures allowed) to reach an 80% chance of passing, which at the mean 25.35 s per swap including recovery from module 2 is about 4.4 hours of testing. If the true rate is 0.89 the chance of passing is very low in every case (at most 7.7%), which is what a test should do. The result of a first round, 56 of 60 (0.933), has a 90% lower bound of 0.871 and so does not yet prove the requirement, although the measured rate looks above 0.90. The team has three options: invest in about 620 trials, improve the design so that the true rate is higher, or discuss with the user a requirement that is tighter than necessary. This information belongs in the test plan before building the prototype.

Line chart of the chance a test passes against the number of test trials from 20 to 700. The green line, for a true rate of 0.9242, rises in a sawtooth from about 0.18 to 0.80 at 620 trials. The pink line, for a true rate of 0.89, stays below 0.08 throughout
Figure 4 Chance that a test proves requirement R1, by number of trials

Ground robots and drones: the interface and the conditions before approaching

The MM-1 cell is one kind of integration between a ground robot and an unmanned aircraft system (UAS): the robot services drones that have landed on pads. A drone is not just an object for the robot to pick up; it is an aircraft with its own flight controller and motors that can spin. If the propellers turn while the arm is close, the danger is obvious, so the interface between the two systems has three layers. The first is the state of the drone, reported over MAVLink: the HEARTBEAT, which says the drone is still on the link; the flag MAV_MODE_FLAG_SAFETY_ARMED in base_mode, meaning the motors are enabled, running or able to start; and the landed_state field of the EXTENDED_SYS_STATE message, whose values are MAV_LANDED_STATE_UNDEFINED, ON_GROUND, IN_AIR, TAKEOFF and LANDING (MAVLink Development Team, n.d.-a). The second layer is the pose of the pad relative to the robot base, which comes from the tags and the calibration of Module 1. The drone can use a target too: MAVLink has a LANDING_TARGET message with which a perception system sends the target position to the flight controller so that it lands more accurately than GPS, which is off by several meters, and possibly to the centimetre level (MAVLink Development Team, n.d.-b). The third layer is physical, such as the power fed to the pad and the battery connector.

The cell is the one that decides. MAVLink has an arm authorization protocol under which the drone arms its motors only if an external entity authorizes it (MAVLink Development Team, n.d.-c). The cell’s PLC can therefore refuse authorization while the robot is inside the pad zone. But these messages are not a safety function (the same principle as in the section on the architecture of the cell), so they must be backed up by cutting the power to the pad or the battery connector with a PLC-controlled device whose safety level has been assessed.

Example 6 When may the robot approach the drone on the pad

MM-1’s conditions (assumed) before approaching are: the drone’s data is fresh (a HEARTBEAT and a state received within an agreed time, for example 3 s), the armed flag is not set, landed_state is ON_GROUND, and the pad pose is within tolerance. The team compares a simple rule that looks only at the armed flag with the full rule, by exploring every possible state (the same approach as Example 1).

# Check the conditions before the robot approaches a landed drone by exploring every possible state (same approach as Example 1)
from itertools import product
LANDED = ["UNDEFINED", "ON_GROUND", "IN_AIR", "TAKEOFF", "LANDING"]   # MAV_LANDED_STATE in EXTENDED_SYS_STATE.landed_state

def naive(fresh, armed, landed, pad_ok):
    return not armed                                  # trusts the armed flag alone

def interlock(fresh, armed, landed, pad_ok):
    # fail closed: the data must be fresh and every condition must pass together
    return fresh and (not armed) and landed == "ON_GROUND" and pad_ok

states = list(product([True, False], [True, False], LANDED, [True, False]))   # (data fresh, armed, landed_state, pad pose in tolerance)
allowed_naive = [s for s in states if naive(*s)]
allowed = [s for s in states if interlock(*s)]
wrongly = [s for s in allowed_naive if not interlock(*s)]
print("combinations: %d, naive rule allows %d, interlock allows %d" % (len(states), len(allowed_naive), len(allowed)))
print("the only allowed combination: fresh=%s armed=%s landed=%s pad_ok=%s" % allowed[0])
print("naive rule wrongly allows %d combinations, for example:" % len(wrongly))
for label, cond in (("stale data", lambda s: not s[0]), ("landed state not ON_GROUND", lambda s: s[0] and s[2] != "ON_GROUND"),
                    ("pad pose out of tolerance", lambda s: s[0] and s[2] == "ON_GROUND" and not s[3])):
    ex = next(s for s in wrongly if cond(s))
    print("   %-27s fresh=%-5s armed=%-5s landed=%-9s pad_ok=%s" % (label, *ex))
combinations: 40, naive rule allows 20, interlock allows 1
the only allowed combination: fresh=True armed=False landed=ON_GROUND pad_ok=True
naive rule wrongly allows 19 combinations, for example:
   stale data                  fresh=False armed=False landed=UNDEFINED pad_ok=True
   landed state not ON_GROUND  fresh=True  armed=False landed=UNDEFINED pad_ok=True
   pad pose out of tolerance   fresh=True  armed=False landed=ON_GROUND pad_ok=False

There are 40 states (2 × 2 × 5 × 2). The rule that looks only at the armed flag allows 20 of them, and 19 are wrong: stale data (the flag may be left over from an old message, when the drone may already have armed), an unknown landed state, and a pad pose that is off. The full rule allows exactly one state, in line with the principle of failing closed: missing or stale data counts as a failure, and the check must be repeated all the time the arm is close. If the armed flag is set or the data stops arriving, the arm must retreat immediately.

Beyond a robot servicing a drone on a pad, research shows several other forms of air-ground cooperation: a ground robot acting as a mobile base that carries the drone and as a charging station (Cai et al., 2023); a drone taking aerial images to build an energy-cost map for a ground robot to plan its path (Wei & Isler, 2019); and mixed teams that must coordinate across robot types, where Queralta et al. (2020) list coordination and interoperability in heterogeneous multi-robot systems as an open research question. Every form must settle three things first: a shared coordinate frame and time (Modules 1 and 4), who decides in each state, and what happens when the link drops.

Industrial and service work: the ISO 8373 definitions and fleet size

ISO 8373:2021 (as summarized by the IFR) defines an industrial robot as an automatically controlled, reprogrammable, multipurpose manipulator, programmable in three or more axes, fixed in place or fixed to a mobile platform, for use in automation applications in an industrial environment. A service robot is a robot in personal or professional use that performs useful tasks for humans or equipment, and the 2021 edition adds the medical robot as a third category (IFR, n.d.-a; IFR, n.d.-b). The split is therefore by environment and purpose of use, not by appearance. MM-1 in a factory cell is an industrial robot on a mobile platform. The IFR names ISO 10218-1, ISO 10218-2 and ISO/TS 15066 as the safety standards of the industrial sector and ISO 13482 as that of the non-industrial sector, and notes that mobile platforms following a set path for factory logistics (AGVs) have standards from ISO/TC 110. The scope of each must be checked in the original before it is applied to real work.

When the space is shared with the general public, the people approaching are untrained and there is no fence. The robot must slow down because stopping distance grows with the square of speed (Example 4), and it loses time waiting for people or lifts. The cycle gets longer, and more robots are needed to deliver the same throughput.

Example 7 How many transport robots are needed in a factory aisle versus a service corridor

The job is 30 transport tasks per hour, 150 m one way, with 40 s of loading and unloading per cycle. In the fenced factory aisle the robot averages 0.80 m/s. In the service corridor shared with people it is limited to an average of 0.50 m/s and waits an extra 30 s per cycle for people or lifts. The team allows robots to be busy at most 80% of the time to keep queues short, and robots are available 85% of the time because of charging and repairs (all values assumed).

# Fleet size of transport robots in a fenced industrial aisle versus a service corridor shared with people (assumed values)
import math
TASKS_PER_H, ROUTE_M, HANDLING_S = 30, 150, 40       # tasks per hour, one-way distance m, loading and unloading time per cycle s
UTIL_CAP, AVAILABILITY = 0.80, 0.85                  # highest allowed busy share (keeps queues short) and share of time available (charging, repairs)
sites = {"industrial aisle (fenced)": (0.80, 0), "service corridor (people)": (0.50, 30)}   # (average speed m/s, wait for people or lifts per cycle s)
cycles, fleets = {}, {}
for name, (v, wait) in sites.items():
    cycles[name] = 2 * ROUTE_M / v + HANDLING_S + wait    # time of one work cycle s (there and back)
    load = TASKS_PER_H * cycles[name] / 3600                # number of robots that must be working all the time
    fleets[name] = math.ceil(load / (UTIL_CAP * AVAILABILITY))
    print("%-26s cycle %4.0f s, workload %.2f robots, fleet %d" % (name, cycles[name], load, fleets[name]))
ind, svc = sites.keys()
served = fleets[ind] * 3600 * UTIL_CAP * AVAILABILITY / cycles[svc]
print("the industrial fleet of %d would serve only %.1f tasks per hour in the service corridor" % (fleets[ind], served))
industrial aisle (fenced)  cycle  415 s, workload 3.46 robots, fleet 6
service corridor (people)  cycle  670 s, workload 5.58 robots, fleet 9
the industrial fleet of 6 would serve only 21.9 tasks per hour in the service corridor

The factory aisle takes 415 s per cycle, a workload of 3.46 robots working all the time; dividing by 0.80 × 0.85 gives 6 robots. The service corridor takes 670 s per cycle, a workload of 5.58, and needs 9 robots. The original fleet of 6 would serve only 21.9 tasks per hour out of 30. The lesson is that moving to a new environment is not just moving the robot: safety, performance and cost must be assessed again, and the average speed and waiting time must be measured from real operating logs.

Service-robot case study: a medicine-delivery robot on a hospital ward

Example 7 counted robots. This case looks inside one service job: a mobile robot like the MM-1 base, with a locked drawer instead of an arm, carries medicines from the pharmacy to a ward. The people around it are patients, visitors and busy staff, none of them trained to work beside a robot. Safety is necessary but not enough. Human-aware navigation surveys summarise what people expect from a robot moving among them in three requirements (Möller et al., 2021, after Kruse et al., 2013): comfort, meaning people are not stressed or inconvenienced; naturalness, meaning the robot moves in a way similar to people; and sociability, meaning it follows cultural conventions such as keeping to one side of a corridor and waiting at a door.

In ROS 2 the first tool for this is the speed filter of Nav2. The team draws a mask map of the building, and each zone of the mask carries a speed limit, either as a percentage of the maximum speed or as an absolute value in m/s. The filter publishes the limit of the robot’s current zone as a SpeedLimit message on the speed_limit topic, and the controller server obeys it. The option enable_path_lookahead samples the planned path so the robot can slow down before it enters a slow zone, not after (Nav2 Maintainers, n.d.). Human-robot interaction completes the job: lights or a sound that show where the robot is about to go, a screen and a badge reader so that only a nurse can open the drawer, and a log of every stop for a person. Those logs become the performance measures: trip time, stops per trip, and time spent waiting at the handover.

Example 8 Speed zones, stopping and throughput of the delivery robot

The robot’s top speed is 1.0 m/s and it uses the time chain of Example 4 (0.150 s reaction, 1.0 m/s² braking). Assume a person may walk straight toward it at 1.4 m/s. The one-way route is 60 m of open corridor at 100% of the top speed, 40 m of ward corridor with patients at 50%, and 20 m past the nurse station at 30%. Each round trip includes two lift rides of 90 s, a 60 s handover and six stops of 5 s for people. The ward needs 60 deliveries in an 8-hour shift, with the same 0.80 utilisation cap and 0.85 availability as Example 7 (all values assumed).

Stopping. During the stopping time the robot covers and the person covers . To be at rest before contact, the robot must detect the person at least away:

speed m/sstopping time srobot travel mperson walks mdetect at least m
1.01.150.651.612.26
0.50.650.200.911.11
0.30.450.090.630.72

On a ward, a patient can step out of a door 1 m from the robot’s path, so only 0.3 m/s (0.72 m) leaves a margin there, and 0.5 m/s (1.11 m) suits a corridor where people are visible from farther away. That is where the zone limits come from.

Throughput. One way takes s, against 120 s with no zones. A round trip is s, against 510 s, so the human-aware robot is 34% slower per trip. The workload is robots working all the time; dividing by gives 2.09, so 3 robots are needed. Without zones the workload is 1.06, which gives 1.56 and only 2 robots.

Comfort and safety therefore cost one robot on this ward. The team can win part of it back without giving up safety: make the slow zones only as long as the risk demands (measure where people actually step out), turn on path lookahead so the robot brakes before the zone instead of inside it, and schedule bulk deliveries outside visiting hours. Any change must be measured again from the logs.

Module lab

Lab: integrate, check and verify the MM-1 cell

  1. Write the interface table of the cell (who sends what, format, frequency, decision owner) for all three seams, MM-1 with the PLC, the PLC with the MES, and MM-1 with the MES, and mark which signals are safety functions that must be a separate hard-wired loop
  2. Adapt the model of example 1 to the handshake logic of the test cell (for example the number of steps in a move and the watchdog threshold), run the state exploration, and fix the logic until no violation is found. Then test on a simulator or hardware using a real PLC
  3. Set up an OPC UA subscription on a sample (test) server for the belt speed and temperature tags, try at least three deadbands, measure notifications per minute and the largest error, and choose a deadband with a reason based on the accuracy the consumer needs
  4. Record the PQ and GQ counters, production time and downtime of the simulated cell over one shift, calculate A, E, QR and OEE, and propose one improvement with an estimate of its effect on OEE
  5. Measure the real stopping time and distance of the base at three speeds, cutting a sensor signal to simulate detection, compare with example 4, and say whether the proposed protective field is enough, writing down which constants must come from the real edition of a standard
  6. Write a table of at least 5 requirements of the prototype, state how each is verified, plan the number of trials of the success-rate requirement with the code of example 5, and report the first-round result with its lower bound

Common mistakes

Watch out

  • Using ROS 2 messages or an ordinary handshake signal in place of a safety function, when it must be a device and logic with a PL
  • Believing a few manual trials find the holes in a handshake, when the problem comes from overlapping timing
  • Treating a model-check result as the real system without testing on hardware
  • Using OPC UA for work needing millisecond delay, or setting a deadband without regard to the accuracy the consumer needs
  • Reporting OEE without stating the definition used, or without tying it to the causes of lost time
  • Applying the industrial-robot standard to a mobile base without checking scope, although ISO 10218 states it does not cover mobility of the base
  • Combining PL by looking only at the PL of each part, not summing the PFHd of the whole function
  • Concluding a requirement is proved from one measured rate, without the lower bound and the number of trials

Summary

  • Divide work by ISA-95 level among the robot, the PLC and the MES and choose the link for each seam; OPC UA suits supervisory data, while safety functions are a separate loop of devices with a PL
  • Check handshake logic by exploring every state, which finds holes that manual trials miss and shows that a link watchdog is needed
  • The OPC UA deadband and publishing interval are decisions about the accuracy and delay of data, not just a way to cut data
  • OEE is the product of A, E and QR, linking engineering decisions such as the retry count to output
  • ISO 10218 does not cover mobility of the base, so ISO 3691-4 is needed as well; stopping distance grows with the square of speed, and the PFHd of a function is the sum over its subsystems
  • A prototype needs a requirements table traced to ways of verifying it, and a statistical requirement needs its number of trials planned in advance
  • Before the robot approaches a drone, check the MAVLink state (HEARTBEAT, the armed flag and landed_state), the pad pose and the freshness of the data, exploring every state and allowing only the safe one. MAVLink messages are not a safety function.
  • ISO 8373 separates industrial from service robots by environment and purpose of use. When people share the space, speed falls and waiting grows, so more robots are needed to deliver the same throughput.

Check your understanding

  1. In an 8-hour shift (PBT = 28,800 s) the cell actually produces (APT) for 20,000 s and makes 1,300 items. The designed time is 14.0 s per item and 1,280 items pass inspection. Calculate A, E, QR and OEE
  2. The base moves at 0.8 m/s with a braking deceleration of 1.0 m/s² and a total reaction time of 0.15 s. What is the stopping distance?
  3. A safety function has a sensor of , a logic controller of and a drive of per hour. What is the total PFHd, and which PL does it fall in?
  4. You want to prove a success rate ≥ 0.95 at 95% confidence with a test that has no failures. How many trials are needed?
  5. A temperature tag is sampled every 100 ms with a deadband of 0.5 degrees. By how much can the value the MES sees differ from the true value at most, and how old can the data be at the oldest with a 2 s publishing interval?
  6. Do ISO 10218-1:2025 and ISO 10218-2:2025 cover the mobility of the base of a robot mounted on a driverless truck?
Answers
  1. , , ,
  2. m
  3. per hour, which lies between and , so PL e (subject also to the other conditions of the standard)
  4. , so 59 trials with no failure
  5. It can differ by at most 0.5 degrees by the definition of the deadband (the last value pushed to the queue), and the data can be about 2 s old at the oldest because of the publishing interval (plus transmission time)
  6. No. The scope of both parts states that mobility when robots or manipulators are fixed to driverless industrial trucks or mobile platforms is outside it. Another standard, such as ISO 3691-4, must be used

Key formulas

OEE indicators
Stopping distance of a protective function
PFHd of functions in series
Zero-failure demonstration trials
Clopper-Pearson lower bound
Transport fleet size

Key references

  1. International Society of Automation. ISA-95 standard: Enterprise-control system integration (ANSI/ISA-95, IEC 62264). link
  2. International Electrotechnical Commission. (2025). Programmable controllers – Part 3: Programming languages (IEC 61131-3:2025, Ed. 4.0). link
  3. International Electrotechnical Commission. (2025). OPC unified architecture – Part 1: Overview and concepts (IEC 62541-1:2025). link
  4. OPC Foundation. (2022). OPC 10000-4: OPC UA Part 4: Services (Release 1.05). Subscription, MonitoredItem and DataChangeFilter sections. link
  5. OPC Foundation & VDMA. (2025). OPC UA for Robotics – Part 1: Vertical integration (OPC 40010-1, Version 1.02). link
  6. International Organization for Standardization. (2014). Automation systems and integration: Key performance indicators (KPIs) for manufacturing operations management: Part 2: Definitions and descriptions (ISO 22400-2:2014). link
  7. Kang, N., Zhao, C., Li, J., & Horst, J. A. (2016). A hierarchical structure of key performance indicators for operation management and continuous improvement in production systems. International Journal of Production Research, 54(21), 6333–6350. link
  8. International Organization for Standardization. (2025). Robotics – Safety requirements – Part 1: Industrial robots (ISO 10218-1:2025). link
  9. International Organization for Standardization. (2025). Robotics – Safety requirements – Part 2: Industrial robot applications and robot cells (ISO 10218-2:2025). link
  10. International Organization for Standardization. (2023). Industrial trucks: Safety requirements and verification: Part 4: Driverless industrial trucks and their systems (ISO 3691-4:2023). link
  11. International Organization for Standardization. (2023). Safety of machinery: Safety-related parts of control systems: Part 1: General principles for design (ISO 13849-1:2023, Ed. 4). link
  12. International Organization for Standardization. (2024). Safety of machinery: Positioning of safeguards with respect to the approach of the human body (ISO 13855:2024, Ed. 3). link
  13. International Organization for Standardization. (2016). Robots and robotic devices – Collaborative robots (ISO/TS 15066:2016). link
  14. Keyence Corporation. PL (performance level): Safety knowledge. link
  15. Vomiero, R. (2022). Practical application of ISO 13849-1 [Seminar slides]. Workplace Safety & Prevention Services (ISSA seminar, May 2022). link
  16. Clopper, C. J., & Pearson, E. S. (1934). The use of confidence or fiducial limits illustrated in the case of the binomial. Biometrika, 26(4), 404–413. link
  17. National Aeronautics and Space Administration. (2016). NASA systems engineering handbook (NASA/SP-2016-6105 Rev 2). link
  18. National Aeronautics and Space Administration. (2023). Technology readiness levels. link
  19. International Organization for Standardization. (2018). Systems and software engineering — Life cycle processes — Requirements engineering (ISO/IEC/IEEE 29148:2018). link
  20. MAVLink Development Team. MAVLink common message set (common.xml). link
  21. MAVLink Development Team. Heartbeat/connection protocol. MAVLink developer guide. link
  22. MAVLink Development Team. Arm authorization. MAVLink developer guide. link
  23. MAVLink Development Team. Landing target protocol. MAVLink developer guide. link
  24. Queralta, J. P., Taipalmaa, J., Can Pullinen, B., Sarker, V. K., Nguyen Gia, T., Tenhunen, H., Gabbouj, M., Raitoharju, J., & Westerlund, T. (2020). Collaborative multi-robot search and rescue: Planning, coordination, perception, and active vision. IEEE Access, 8, 191617–191643. link
  25. Cai, B., Lu, F., & Zhou, L. (2023). Energy-aware routing algorithm for mobile ground-to-air charging (arXiv:2310.07729). arXiv. link
  26. Wei, M., & Isler, V. (2019). Air to ground collaboration for energy-efficient path planning for ground robots. In 2019 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (pp. 1949–1954). IEEE. link
  27. International Organization for Standardization. (2021). Robotics – Vocabulary (ISO 8373:2021). link
  28. International Federation of Robotics. Industrial robots: definition and classification. link
  29. International Federation of Robotics. Service robots: definition and standardization. link
  30. Möller, R., Furnari, A., Battiato, S., Härmä, A., & Farinella, G. M. (2021). A survey on human-aware robot navigation. Robotics and Autonomous Systems, 145, 103837. link
  31. Kruse, T., Pandey, A. K., Alami, R., & Kirsch, A. (2013). Human-aware robot navigation: A survey. Robotics and Autonomous Systems, 61(12), 1726-1743. link
  32. Nav2 Maintainers. (n.d.). Speed filter parameters. Nav2 documentation (rolling). link

Further reading

Study the assigned knowledge units in advance, review media and take the module quiz

In class / field

Lab or field practice from worksheets with a safety checklist

Learning evidence: Checked worksheets and quiz results

Module quiz

This is a formative self-check, not a graded exam

Knowledge domain: Automation, robotics and swarms · Management, innovation and professional practice · Aircraft, structures and design · Delivery, indoor operations and warehousing · Communications, networks and IoT