UAT 465 UAS Technology for Smart Farming and Precision Agriculture
Worksheet 4 Sprayer calibration and spreading test
Objective
Calibrate the spray drone's flow rate, check the pump can serve every zone, find the pass spacing for even spreading and prepare a safety checklist
Equipment and materials
- Registered spraying and spreading drone
- Plain water, catch containers, measuring jug and stopwatch
- Collection trays every 1 m and a scale
- Test material such as plastic pellets or fertiliser approved by the lecturer
- Anemometer
- Python and the module 4 example code
Safety
- Plain water only; no pesticides in this lab
- Fly within CAAT conditions in visual line of sight; keep people clear of the large drone's passes; tray handlers enter only after landing and motor shutdown
- Stop testing when wind exceeds the lecturer's limit
- Wear glasses and gloves when handling test material
- During the ground feeder test, remove the propellers or strap the drone down before powering up
Steps
- Fill the tank with plain water; time and catch every nozzle at working pressure; compare real flow with the setting
- Compute flow and speed for each zone of the group's prescription with Example 1
- Lay trays across the pass, spread test material and weigh each tray
- Before computing the CV, screen the tray rows with the lesson's rules (blank, negative, wrong unit, duplicate ID), and compute the mass and CG of your aircraft at full and empty tank with the tank-moving example code
- Find the pass spacing that meets the CV criterion with Example 2
- Write a pre-spray safety checklist following Department of Agriculture guidance
- Set the rate for the test material with a ground catch test as in Example 4 (propellers removed or the drone strapped down), and time one plain-water spraying job to find its field efficiency as in Example 5
Record of results
| Nozzle | Volume caught (mL) | Time (s) | Real flow (L/min) | Set flow (L/min) | Difference from setting (%) |
|---|---|---|---|---|---|
| Tray ID | Position (m) | Mass (g) | Unit recorded | Kept or held (reason) |
|---|---|---|---|---|
Questions
Which zone of your group's prescription needs more flow than the pump allows, what speed must the drone slow to, and if it does not slow, how much does the zone really get?
Which pass spacing did your group choose and why? What can a passing CV not tell you?
Why must the CG be checked at both full and empty tank? Is your aircraft's result inside the range in its manual?
How does the field efficiency you timed compare with 62% for the 150-rai field and 26% for the 5.5-rai plot in Example 5, and which part of the job time could be cut the most?
Check before you hand in
What to hand in
- Flow per nozzle table
- Flow and speed per zone
- Tray weights and chosen pass spacing
- Pre-spray safety checklist
- Tray screening result and mass and CG calculation
- Ground catch test and field efficiency
- Lab notebook