From aerodynamic results to DroneSim: preparing force tables
Define the units, axes, data ranges and evidence of a force table before using it in a flight simulation model.
Sending meaningful quantities into the simulation
By the end of this lesson, learners will be able to prepare a force data contract and write a verification plan for the interface. A motion simulator needs forces and moments in a well-defined coordinate frame, whereas CFD or experimental data may provide coefficients under a different definition. A unit conversion error or a flipped sign can make the aircraft accelerate in the wrong direction, even when the source data were computed correctly.
This lesson includes an airframe drag table interface that has been installed and tested in DroneSim together with a synthetic example to prove the data path. The propeller formulas and recording templates remain a separate foundation from this adapter. There is no validated force set for flight use, and the prescribed actuator-disk force results from the CFD lesson are not used as airframe drag.
This diagram is a general process for future aerodynamic data, including propeller data that may require RPM. The adapter actually working in this lesson accepts only fixed-direction, fixed-density airframe drag and does not use RPM.
Extension lab: from force tables to motion
Start this section after reading the three cases near the ground, around a building and payload You will practise deciding which model the available forces apply to, checking continuous motion, and preparing data for comparison with real measurements.
Download the force checking and hand-off workbook It contains a Python evidence-checking tool, a comparison example with uncertainty, and demonstration code for a continuous trajectory in DroneSim with pre-run results. The Python code runs on Windows/Linux without installing extra libraries, while running DroneSim requires the project and the interface described in the README.
Whose force is it: check correctly before transforming axes
| Result from Phase 2 | Reported force | What cannot yet be sent to the airframe drag model |
|---|---|---|
| near the ground | Fluid force on the ground | The ground is not the airframe, and the disk force was prescribed in advance |
| around a building | Fluid force on the building | The building force is not the force on a drone flying past |
| payload | Force on a box in the downwash | Combines the wind effect with the prescribed actuator disk; it is not whole-airframe drag as a function of flight speed |
All 14 cases meet the numerical completion criteria of the training set, but there are still no measured data confirming agreement with the geometry, fluid properties and boundaries of these cases The tools in the workbook therefore keep the results together with the reasons they cannot yet be handed off, and do not relabel them as drone forces. This is using data according to their correct meaning, following the principle of NASA Verification and Validation
Continuous motion with a checkable answer
The new example uses synthetic data with stepDynamics the actual DroneSim code, continuing the state from the previous step without moving the aircraft back to its starting point. The aircraft is set level at a height of 10 m with an initial horizontal speed of 5 m/s, and the initial motor speed is set so that lift balances weight, with the battery voltage held constant. This exercise therefore studies horizontal drag under restricted conditions; it is not a piloted flight mission or a gusting-wind scenario.
The example table over 0–5 m/s specifies Fₓ = −kvₓ with k = 0.06 N·s/m, where the minus sign means the drag opposes the direction of motion. Substituting into m dvₓ/dt = Fₓ gives the analytical solution:
vₓ(t) = v₀ exp(−kt/m) and x(t) − x₀ = (mv₀/k)[1 − exp(−kt/m)]
m is the mass in kg, t is time in s, v₀ = 5 m/s and x is the distance in m. The quantity kt/m is dimensionless. This formula applies only within the linear range of the table described above. The 5–10 m/s range of the table has a different slope, so the same formula must not be used across ranges without reconsideration.
Try comparing time steps of 0.002, 0.001 and 0.0005 s with this solution to separate time-integration error from the correctness of the physics. Compare x and v at the same time, not rows with the same index, which may correspond to different times. The original DroneSim drag is a different model, so its trajectory should not be expected to match the synthetic table.

The left graph shows an actual continuous run of the code, but the drag input is a value set up for testing. The right graph shows the difference from the analytical solution, not an error from real flight. Open the full-size graph
Results at 2 s, using the example aircraft mass of 0.5043 kg and a time step of 0.0005 s:
| Model | Final vₓ (m/s) | Distance x (m) |
|---|---|---|
| Original DroneSim drag | 4.468355 | 9.448308 |
| Synthetic table | 3.941168 | 8.898950 |
This difference comes from the choice of drag model; it does not indicate which one better matches a real drone. The file dronesim/result/trajectory.csv contains every time step for re-checking, while the JSON records the mass, trim setting and condition-check results. The table's limitations remain the same: the direction of relative velocity in the body frame is constant, the density is constant and the body rotation rate is zero. If these conditions are violated, the interface stops with an error.
Preparing to compare with measured values without adding accuracy that does not yet exist
Before comparing, everything must match: object, geometry, measured quantity, axes, moment reference point, density, viscosity, inflow, boundaries and time-averaging method. The tool rejects pairs whose conditions differ or whose uncertainty is not yet known. Matching IDs is only a data contract; the user must still check the actual evidence.
Let S be the simulated value and D the measured value in the same units. The difference is E = S − D If uₛ and uᴅ are evaluated standard uncertainties and the sources of uncertainty are independent, they combine as u꜀ = √(uₛ² + uᴅ²) according to NIST TN 1297 If they are correlated, a covariance term must also be considered; the example tool does not accept that case.
Practice example with values that are entirely hypothetical): S = 0.30 N, D = 0.28 N, uₛ = 0.01 N and uᴅ = 0.02 N give E = 0.02 N, u꜀ ≈ 0.02236 N and |E|/u꜀ ≈ 0.894. The last number indicates the size of the difference relative to the combined uncertainty; it is not a certification pass score and does not prove that the model is valid for all conditions.
Try it: Change the viscosity in the example file on one side only, then check that the system rejects the comparison. Next, restore the value and remove the uncertainty; the system should ask for the data to be corrected rather than filling the gap with zero. Do not put the difference between the two Phase 2 grids directly in as uₛ, because no error bound has yet been evaluated according to NASA Spatial Convergence
In the comparison file, flow_velocity_m_s means the relative wind flowing past the object, whereas DroneSim's velocity_direction_frd means the airframe moving through the air. These two definitions have opposite signs: for example, a +x wind pushes a stationary object toward +x, but an aircraft moving toward +x in still air experiences drag toward −x.
The next section explains the data contract, the axes and the original interface code in detail. The propeller work at the end of the lesson is a separate case study whose evidence status is independent of this experimental set.
Definitions that must match before building a table
If you want to practise with real measured data instead of hypothetical numbers, read NASA MTB2 experimental data to select a Run/Point and check the units and wind-tunnel conditions. That dataset gives rotor hub forces, so it is not yet an airframe drag table for this adapter.
Let n be revolutions per second (not rpm), D the diameter in m, V the speed along the reference axis in m/s, T the thrust in N and P the power in W. Using the standard definitions J = V/(nD), CT = T/(ρn²D⁴), CP = P/(ρn³D⁵) therefore T = CTρn²D⁴ and P = CPρn³D⁵
When n > 0, the shaft torque is Q = P/(2πn) in N·m. The symbol Q here denotes torque, unlike the flow rate Q in the channel-flow lesson, so column names must be stated clearly. Formulas that divide by n are not used directly at zero rotational speed.
UIUC Propeller Database is a wind-tunnel data source for small propellers. Its Reynolds number definition in the static plots uses the chord and rotational speed at the 75% radius station, so it should not be compared with a diameter-based Re without conversion. This lesson links directly to the owner's data; it does not copy the database or automatically claim redistribution rights.
Unit conversion example labelled as hypothetical
Given n = 100 rev/s = 6,000 rpm, D = 0.2 m, ρ = 1.225 kg/m³, CT = 0.10 and CP = 0.05, we obtain T = 1.96 N, P = 19.6 W and Q ≈ 0.03119 N·m These values are set up to practise the formulas; they are not data for any propeller model or results from UIUC.
If V = 5 m/s, then J = 0.25, but the original CT should not be reused automatically, because the coefficients may change with J and Reynolds number. The power P in the formula is shaft power, not electrical power from the battery; a motor/ESC model and efficiencies are also needed to link it to energy consumption.
The data contract to agree with the receiving side
| Item | What must be specified |
|---|---|
| Inputs | Rotational speed in either rpm or rad/s with its converter, relative airspeed, ρ and the variables the data cover |
| Outputs | Forces in N and moments in N·m, with axes, coordinate frame and sign convention |
| Coordinate frame | Definitions of the rotor/body/world axes and the rotation matrix actually used |
| Point of force application | Position relative to the centre of mass, for computing the moment r × F |
| Provenance | Experimental source or solver version, case ID, geometry ID, date and uncertainty |
| Validity range | Ranges of rotational speed, airspeed and density, and the conditions that have been checked |
| Out-of-range values | Reject or warn according to the agreed policy; do not extrapolate silently |
| Time | Mean or instantaneous values, averaging window, latency and update rate |
The table in the channel-flow workbook is still a planning template. The adapter actually used below defines a contract specific to airframe drag, with provenance separated into synthetic, simulation or experiment; these provenance labels are not certificates of accuracy.
The working interface and its data scope
On the following DroneSim baseline commit:
b1e26271a08090c278e6c6a45ed64e9f7f7a0cec
Added AirframeForceProvider as an optional sixth argument of stepDynamics Existing callers still use the original drag model. When a provider is passed in, forces and moments from the table replace params.dragCoef for airframe drag only. Rotor thrust, reaction torque, gravity and the motor system remain in the original model. There is no UI toggle and no automatic table loading.
Create a provider with the command:
createAerodynamicProvider(data, { densityKgM3, windWorldMps })
The function checks the schema, SI units, provenance and force_scope being airframe_drag_only before creating the provider. The table uses the FRD frame: x forward, y right, z down whereas the DroneSim body frame is FLU: x forward, y left, z up so forces and moments are rotated by (x, −y, −z) before forces are transformed to the world frame.
reference_from_cg_m is the vector from the CG to the moment reference point of the table. The adapter computes MCG = Mreference + r × F after transforming into the FLU frame. The reference point must be checked against the actual source to avoid double-counting the moment.
This version of the table supports one-dimensional speed in a constant direction of motion through the air in the body frame, constant density and zero body angular rates The world wind is subtracted from the airframe velocity before the axis transformation; this direction is opposite to the direction of the wind blowing onto the aircraft. Linear interpolation is used only within the speed range, with no extrapolation and no automatic adjustment of density or angle. Out-of-range or non-conforming inputs throw an error instead of a silent fallback.
Demonstrating one time step and downloading the code
Download the DroneSim adapter workbook with test code, patch and JSON results It contains copies of the five original adapter files, a patch limited to dynamics.ts, the baseline and a SHA256 manifest. It does not include the whole simulator or other changes in the project. Read README.md to apply it to a fresh checkout with a matching baseline, then from app run:
pnpm exec vitest run --maxWorkers=2
pnpm typecheck
pnpm build
New-Item -ItemType Directory -Force output
pnpm exec tsx scripts/aerodynamic-demo.ts output/aerodynamic-demo-reproduced.json
Give the output a new name each time, because the demo does not overwrite existing files. The recorded results use the table synthetic at 0, 5 and 10 m/s giving Fx = 0, −0.3 and −1.2 N respectively. Each comparison restarts at a height of 10 m and they are not chained into a trajectory:
With the same initial vx of 5 m/s and Δt = 0.001 s for both cases:
| Drag model | vx after the step (m/s) |
|---|---|
| Original drag | 4.999702558001189 |
| Synthetic override | 4.99940511600238 |
Integration runs passed via 650 tests with --maxWorkers=2, together with typecheck, build and lint on the modified TypeScript only. These results check software behaviour, including axes, moments, interpolation and the rejection of non-conforming data; they are not flight validation. Gravity can change the direction of velocity immediately, so this fixed-direction table should not be used for general trajectories.
CFD and the adapter are two separate experiments: the 0.08 N source in the previous lesson is a rotor-like force prescribed on the fluid, not an airframe drag predicted by the solver. Feeding it into the adapter would assign the force ownership incorrectly. Before connecting real data, an airframe drag is needed whose geometry, density, direction, reference point and range of conditions match, with no rotor or gravity included.
Interface verification plan before trusting the results
Start by testing the conversion of rpm to rad/s and to n, then input a synthetic force of known direction to check the axes. Test a force offset from the centre of mass to check r × F, and separate the reaction moment from the shaft torque. Next, test interpolation within the range and check that out-of-range inputs are handled according to the contract, including the zero-speed case.
Once real data are available, compare the forces with experiments under matching conditions, assess sensitivity to density, rotational speed and averaging method, and only then test the combined motion. The fact that FLOWUnsteady supports time-dependent aerodynamics does not mean that any result can be used in DroneSim immediately, nor that rotor–rotor interaction has been fully simulated in a single-propeller table.
Real-hardware case study: APC Thin Electric 10×5E
This propeller model was chosen as a starting point because UIUC wind-tunnel measurements and manufacturer documentation are available for cross-checking. Its nominal size is 10 in diameter × 5 in pitch; the diameter used for unit conversion is D = 0.254 m. Choosing this model as a case study does not mean it suits every motor or drone.
| Source | Used for |
|---|---|
| UIUC static: RPM, CT, CP | Experimental data for the case with no forward speed |
| UIUC dynamic: set near 6,000 rpm | Studying how CT/CP change with advance ratio; use the actual rotational speed given in the supporting data |
| APC performance data | Results from the manufacturer's analysis software, not independent measurements |
Coefficient conversion example: the UIUC row at 5,869 rpm gives CT = 0.0977 and CP = 0.0373. Assuming a density for calculation of ρ = 1.225 kg/m³ and n = 5,869/60 rev/s, the formulas above give T ≈ 4.7664 N, P ≈ 45.2118 W, Q ≈ 0.073563 N·m These are back-calculated values under the specified ρ; they do not claim that the density during the experiment was the same, nor are they battery electrical power.
The validation sequence is: choose static or dynamic to match the problem → record the file, version and conditions → compute CT/CP from the model using the same definitions → compare at matching rotational speed and J → analyse the differences and uncertainty. Interpolation between points for learning must stay within the data range and does not replace validation against independent data.
The original 0.08 N actuator-disk set is not yet a model of this propeller. The propeller geometry/model and matching conditions must be built before the UIUC results can be used for validation, and the adapter that replaces airframe drag is not a route for importing propeller thrust tables.
Data files and images are linked directly from their owners; no copy of the database is included in the ZIP. Read the citation method at UIUC Propeller Database and check any additional rights before redistributing the data or geometry.
Checking the geometry before building CFD of this propeller
We opened the APC geometry archive of February 2026 and checked the file 10x5E-PERF.PE0 The file header is v2025-1001, dated 24 February 2026, giving station/chord in inches and twist in degrees, along with thickness, sweep and rake. The file specifies E63 and APC12 with transition start/end points; APC explains that APC12 is equivalent to NACA 4412, but this statement alone does not specify the blending method or the full three-dimensional surface.
Compare with the UIUC geometry table which gives r/R, c/R and β. The two datasets are not confirmed to be the same specimen or revision, and APC separates angles based on the leading/trailing-edge datum from pitch measured with instruments, so the difference between β and twist should not immediately be called a measurement error.
Unit check example: Using the nominal radius R = 0.127 m at r/R = 0.75 gives r = 0.09525 m; the UIUC row gives c/R = 0.128, so the chord c = 0.016256 m or 16.256 mm, and β = 13.39°. This is a data conversion, not the construction of an airfoil from a single blade-width value.
Download the Python geometry checking and comparison kit and then download the UIUC table and the APC archive separately from their owners as described in the README. The tool matches three radial stations using linear interpolation, records hashes and reports the differences descriptively; it does not predict thrust and does not extend data beyond their range.
Results from the files actually checked: at r/R = 0.75, the APC table after interpolation gives chord ≈ 17.137 mm and twist ≈ 11.983°, while UIUC gives a chord of 16.256 mm and β of 13.39°. The widths differ by about 0.881 mm, but it cannot yet be concluded which dataset is wrong, because the propeller revision and the angle datum have not been confirmed to match. Keep this result as data-checking evidence before choosing a model.
Before running the real propeller, further checks are needed: section coordinates and the transition method, axis/rotation-direction definitions, hub/root/tip, a revision that matches the tested propeller, and a closed surface that can be meshed. Only then should the rotational speed and J be chosen to match the UIUC data and a grid/boundary study carried out. The existing files are sufficient for practising geometry data checks, but they do not yet confirm a CAD model matching the original specimen.
A dataset ready for further study: MS1101 from ENOLA

Image generated from the geometry data of UPV / ENOLA and the adapted image is published under CC BY-SA 4.0 It is a geometry reference image, not a CFD image or a product image. Open the full-size image
To move forward without guessing the APC sections, we chose the T-Motor MS1101 in the ENOLA dataset as an additional real-data case study. We downloaded and inspected the archive and found an OBJ file, a propeller table, thrust and torque measurements, and the researchers' OpenFOAM results. These data are sufficient to start checking the geometry and setting up comparison cases, but they are neither CFD results run by this site nor confirmation of the model's accuracy. Source data and downloads
Which file to start from
Download the Propeller_Database.zip from the owner, then open the folder BBDD/T-Motor/MS1101/ on Windows or Linux:
| What you want to do | File to use |
|---|---|
| Read the test method and angle definition | README.txt, an angle of 0° means flow along the rotation axis |
| View the 3D geometry | geometry/MS1101.obj, open with software that supports OBJ |
| Check chord and twist | geometry/MS110_blade_definition.csv, chord is in mm |
| Study the force measurements | results/MS1101_exp_0deg.csv, includes RPM, V, thrust and torque with units |
| Compare calculation methods | results/MS1101_OF_mrf.csv and MS1101_OF_urans.csv, these are the original researchers' results |
Download our guide: data check log and case sheet It contains a file list, hashes, calculation examples and case-study preparation steps, without including the source database. The authors license the data under CC BY-SA 4.0 and specify use for study/research, not for flight decisions or missions whose safety depends on these results.
Calculation example from real measurements
Select the row 5088 RPM, V = 0 m/s which records a thrust of 4.6688 N and a torque of 0.05954 N·m:
n = 5088 ÷ 60 = 84.8 rev/s
P = 2πnQ = 2π × 84.8 × 0.05954 ≈ 31.724 W
This is the mechanical shaft power not electrical power from the battery. Finding electrical power also requires knowing the motor and ESC losses. In hover, the formula TV/P gives zero, so it should not be taken to mean the propeller is inefficient; use an appropriate hover metric separately.
What has been checked, and what must be preserved in the model
- The OBJ has 335,812 vertices and 671,620 triangles. Indexed edges were checked and each edge borders two faces, so no open edges were found by this method, but this does not guarantee the absence of self-intersections or that a good volume mesh can be generated.
- The Excel file states a nominal D = 0.2794 m while the X extent in the OBJ equals 0.280288 Further checking against the MS1101 manufacturer page which states a measured size of 280.3 mm provides evidence supporting metres as the OBJ unit, with a difference of only 0.012 mm. Keep the original surface and use the nominal size separately for normalization; do not scale the surface to match the 11-inch figure.
- The twist table at r/R = 0.9 gives 8.75°, but the radians column gives 0.16, which does not match, so the OBJ is used as the primary geometry rather than rebuilding the surface from the table with silent data corrections.
- A CQ of NaN means missing data, not zero. Atmospheric conditions and uncertainty must be checked for each test case before claiming that validation has passed.
A reproducible test sequence
- Keep the original files and check the hashes from the guide package. Inspect the geometry to define the rotation axis and the torque sign.
- Start hover at 5088 RPM to match the test row, using Ω ≈ 532.814 rad/s Record the density and viscosity chosen. If they do not yet match the experiment, label it a preliminary comparison.
- Start with MRF, then study the domain size and the grid at no fewer than three levels, checking thrust, torque, y+ and residuals together before moving on to URANS.
- Compare T and Q separately, and do not set your own percentage pass criterion without uncertainty data. If the 3000/6000 RPM results from the OpenFOAM files are used, the interpolation of the test rows must also be stated.
- Only once verified results are available should a propeller force interface be designed in DroneSim, separate from the existing airframe-drag adapter.
The work of Aular et al. (2026) supports checking MRF limitations in inclined flow, but it uses a reference propeller of a different geometry, so the error values from that work cannot be used directly as pass criteria for the MS1101.
Comparing the source results before using them as criteria

Graph adapted from UPV / ENOLA v1 under CC BY-SA 4.0. These are the original researchers' results, not CFD results that we ran ourselves. There are no error bars because uncertainty data for this test set are not yet available. Open the full-size graph
At 6000 RPM, linear interpolation of the measurements at 5815 and 6068 RPM gives T ≈ 6.46244 N, Q ≈ 0.0814705 N·m while the source MRF result gives 5.5896 N and 0.1134 N·m a difference of about −13.51% and +39.19% respectively. These figures are descriptive differences, not pass/fail scores, and the interpolated point is not a new measurement.
Formula for re-checking: difference (%) = 100 × (simulated value − interpolated experimental value) ÷ interpolated experimental value. If the divisor is zero, use the absolute difference instead. The tool does not compare points outside the measured RPM range.
Download the Python tool for comparing ENOLA results It runs on Windows/Linux without installing extra libraries. Download the source archive separately as described in the README. The tool checks hashes before reading files and does not overwrite earlier reports.
A normalization check on the 5088 RPM row found that, using the standard definitions and D = 0.2794 m, back-calculation from T/CT gives a density of 1.20984 but from Q/CP gives 1.19584 kg/m³ These figures are only consistency-check tools, not measured densities. Changing the diameter alone cannot resolve the difference for every row, so the averaging and normalization definitions must be obtained from the source before concluding the cause.
What cannot yet be confirmed on the researchers' behalf: the actual atmospheric conditions during measurement, sensor calibration and the uncertainty budget are not in the README/CSV that were checked. The temperature or density that the paper used to set up its CFD should therefore not be cited as the test conditions. The values we set for our runs must be labelled as simulation assumptions.
Real propeller run results: checking readiness before trusting simulated values
Latest result: the convergence problem has been resolved for one case
The MS1101 case on a 156,104-cell grid has now passed the numerical criteria after changing the pressure–velocity coupling method from SIMPLE to SIMPLEC following the OpenCFD guidance We used consistent=yes, pressure relaxation=1 and U/k/omega relaxation=0.7 as a set of settings tested together. The geometry, fluid, mesh and pass criteria were unchanged, so we have not yet isolated whether any single setting is solely responsible.

The solver met the 10⁻⁵ residual criterion at iteration 3,554 after which we disabled only the automatic stop to run a further 200 iterations for checking, evaluated against the same criteria. The result at iteration 3,754 is a thrust of 3.38252 N and a resisting torque of 0.0848474 N·m with a maximum residual of 1.25 × 10⁻⁶ The thrust fluctuation range over the last 100 iterations was only 0.000649% and over the last 200 iterations 0.00515% so both the residuals and the force steadiness passed over the checked window.
This resolves the iterative convergence of this case but it is not yet confirmation that the forces match reality: below are screening results for grid/boundary sensitivity and the near-wall distribution, which are not yet sufficient to declare grid independence. The latest yPlus values of the continued check are at checkpoint 3,750, not at the force iteration 3,754, and still span about 2.61–90.40. The evidence is kept separately in simplec with simplec-hold of ZIP MS1101
Reading y⁺ to plan the near-wall grid
Next to the propeller surface, velocity changes rapidly over a short distance, so a grid that looks fine compared with the propeller size may still not be fine enough for this layer. The dimensionless distance y⁺ = y₁uτ/ν links the distance from the wall to the first cell centre, y₁, with the kinematic viscosity ν, using the friction velocity defined as uτ = √(|τw|/ρ); τw is the wall shear stress in Pa, and uτ is in m/s.
Practice example with an assumed uτ: using ν = 1.5 × 10⁻⁵ m²/s and uτ = 1 m/s, a target of y⁺ = 1 gives y₁ = 15 µm; a target of 30 gives y₁ = 0.45 mm. These numbers show the effect of the choice of target; they are not a grid specification for the MS1101, because the actual uτ varies with position and a compatible wall treatment must be chosen first.
If the first-layer cell has its centre near mid-thickness, a starting estimate may be Δy₁ ≈ 2y₁ then check the actual distance after generating the grid. For N layers growing in thickness at a constant ratio g, the total thickness is H = Δy₁(gᴺ − 1)/(g − 1) when g ≠ 1. For example, Δy₁ = 30 µm, g = 1.2 and N = 10 give H ≈ 0.779 mm This formula does not confirm that the grid layers cover the boundary layer or that they can be generated completely along the blade edges. See the procedure in OpenCFD Layer addition
For the 156,104-cell reference grid at checkpoint 3,750, per-face values on 15,536 surface faces were checked and 76.70% of the faces lie in the range 5 ≤ y⁺ < 30, even though the mean is 22.99, so the distribution should always be checked as well. This proportion counts faces and is not area-weighted because the faces have unequal areas. The bins are used to read the distribution, not as criteria for certifying a wall function.
The values in the file use the yPlus function of OpenFOAM 2512 with the default useWallFunction=true which relies on the expression of the selected nut wall function, so the calculation method must be stated when comparing with values obtained directly from wall shear. The current set does not yet have prism layers, and the near-wall sensitivity study has not been closed.
Re-checking practice: open wall-yplus.csv and wall-resolution.json in the ZIP for each case, check that the face counts across all bins add up to the total number of faces, then check field_iteration before comparing with the forces. Surface values may come from a checkpoint before the final force iteration, depending on the file-writing interval.
Grid and boundary sensitivity: the evidence available now

We compared the averages over the last 100 iterations of the SIMPLEC runs after checking that the physical values and the configuration files that should be fixed were identical. Case L4 and the reference grid L5 passed the residual and force criteria. L6 was continued from checkpoint 1,300 to 1,800 iterations; the residuals at the final iteration passed, but only 48 of the last 100 iterations met the criterion, so the percentage difference relative to the reference grid has not yet been computed.
| Case | Cells | Mean thrust (N) | Mean resisting torque (N·m) | Grid comparison status |
|---|---|---|---|---|
| L4 coarse surface refinement | 85,289 | 3.18582 | 0.0861272 | Passed criteria; differs from reference L5 by 5.82% and 1.51% respectively |
| L5 reference grid | 156,104 | 3.38252 | 0.0848474 | Passed criteria |
| L6 fine surface refinement | 399,881 | 3.54109 | 0.0833805 | Final iteration passed, but residuals passed in only 48/100 of the last iterations; results cannot yet be compared |
| L5 with domain enlarged 1.5 times | 234,113 | 3.32664 | 0.0849539 | Passed criteria; changed from reference L5 by 1.65% and 0.125% |
These results indicate that increasing the resolution on the surface alone changes the computed forces between L4 and L5, and a single domain enlargement also shows a difference, so grid and boundary effects cannot yet be ruled out. However, it is still not possible to compute a GCI or declare grid independence: the refinement is local and does not reduce cell size systematically over the whole propeller and wake; case L6 has not passed the residual window even after additional iterations; the separately tested relaxation set also failed the force criteria; there are no prism layers yet and first-order upwind is used; and a single level of domain enlargement is not enough to test independence from the boundaries. NASA recommends using converged solutions on successively refined grids and checking the asymptotic range before Richardson/GCI estimation (NASA Spatial Convergence).
The y⁺ values span 5.84–151.78 for case L4 and 2.61–90.40 for the L5 reference; L6 at checkpoint 1,800 spans 1.03–53.51, with 96.00% of the surface faces in the 5–30 range. These bracketed figures count faces, are not area-weighted and are not evidence of shear-stress accuracy. The OpenFOAM manual page explains that y⁺ must be interpreted consistently with the selected wall function (OpenFOAM Wall Functions); the seemingly lower L6 values therefore do not make the L6 results usable for comparison while the residual window has not passed.
Further checking found that the residuals of Ux and k in L6 oscillate repeatedly near the criterion, even though the force and torque values at the end of the set are very steady. A separate diagnostic experiment from checkpoint 1,800, reducing the under-relaxation of U/k/omega from 0.7 to 0.35, made the thrust fluctuate by 14.19% over the last 100 iterations, with a maximum residual in that window of 2.28×10⁻³ (final iteration 1.49×10⁻³), so this set of results is rejected and not used for grid comparison.
Another experiment reduced only the pressure field relaxation p from 1.0 to 0.3 while keeping U/k/omega at 0.7, from the same checkpoint. Over the 100-iteration window (1,901–2,000), residuals passed in only 1/100 iterations; Ux passed in 1, Uy in 4 and Uz in 9 iterations, while p/k/omega passed in all of them. Thrust and torque were very steady (peak-to-peak ranges of 0.00344% and 0.00157%), but the residual gate was not passed, so the results cannot yet be used. The two tests indicate that reducing relaxation alone does not solve this problem; the velocity equations/mesh/discretization must be investigated further, and the same protocol must be applied to every grid if solver settings are changed. All these results are numerical diagnostics, not validation results. The principles in OpenFOAM SIMPLE and under-relaxation explain that relaxation helps limit changes in variables/equations but is not in itself a criterion for confirming convergence.
Testing the hypothesis that “more iterations will make it pass”
We used a separate copy from the L6 checkpoint at iteration 1,800 and continued to 2,000, changing only endTime; the hashes of the mesh, geometry, physics, schemes, fvSolution and checkpoint fields matched the originals. Over iterations 1,901–2,000, the combined residuals passed in 46/100 compared with 48/100 before continuing, with Ux and k each passing in 68/100, while Uy passed in 95/100, and the maximum value was 1.36 × 10⁻⁵
Although the residuals have not yet passed, the mean thrust and resisting torque between the windows 1,701–1,800 and 1,901–2,000 changed by only 0.0000073% and 0.0000040% respectively. It can therefore only be concluded that the forces are nearly constant while the set residual criterion has not yet been met. A residual-pattern checking tool found a recurrence of Ux/k at a lag of about 18 SIMPLE iterations; this is a pattern in solver iterations, not a physical time period, and its cause has not yet been identified.

We wrote the quality fields of checkMesh and the cell-centre coordinates from a separate copy of the mesh, then ranked cells by non-orthogonality, skewness, aspect ratio, volume and volume ratio. The highest non-orthogonality was found at a radius of about 35 mm and the highest skewness at about 140 mm, within the rotor zone of the model (r ≤ 150 mm, −25 ≤ z ≤ 25 mm). These locations are cell centres used to point to areas for further checking; they do not confirm that those points intersect the blade surface or cause the residual cycle. The criterion Mesh OK and these statistics/rankings are diagnostic data and do not create a new pass/fail gate.

Per-cell CSV/JSON files are in the MS1101 package without adding the 87 MB mesh or raw quality fields to the ZIP. The reproduction method uses OpenFOAM checkMesh -writeAllFields and postProcess -func writeCellCentres according to OpenFOAM 2512 checkMesh documentation and writeCellCentres. These locations have been linked with the residual and gradient maps; this diagnostic result is not used for grid comparison or to confirm experimental results.
Where the Ux and k fields change between checkpoints
We compared per-cell values of Ux and k saved at iterations 1,800→1,950 and 1,950→2,000 on the 399,881 cells of L6. The mesh in the diagnostic copy has constant/polyMesh hashes matching the solver case, so cell indices can be paired. The following results are changes in the saved solution not residuals or gradients:
| Iteration range | Field | Volume-weighted L2 change relative to the initial field | Cell-count p95 of |Δ| | Share of Δ² in r = 0.15–0.18 m |
|---|---|---|---|---|
| 1,800→1,950 | Ux | 0.0306% | 0.000157 m/s | 95.9% |
| 1,800→1,950 | k | 0.0712% | 0.0000190 m²/s² | 99.4% |
| 1,950→2,000 | Ux | 0.0211% | 0.000111 m/s | 95.7% |
| 1,950→2,000 | k | 0.0256% | 0.0000141 m²/s² | 97.3% |
The weighting uses Σ(V·|Δfield|²) in each radial band, divided by the sum over the whole domain, and r = √(x²+y²); each radial band therefore includes all z values. The locations of largest change in all four cases are at r ≈ 0.153–0.167 m, z ≈ 0.0093 m, with non-orthogonality of about 25.2°. The geometric envelope of the rotor (r ≤ 0.15 m, |z| ≤ 0.025 m) accounts for only 0.10–0.42% of the Δ² change, depending on the field and window selected, so the large values are concentrated outside that envelope in the outer radial band.
This helps point to areas for further checking, but it does not tell the cause of the residual cycle: checkpoint differences are neither residual equations nor physical time, and they are not validation data for grid comparison. See the JSON/CSV and reproduction scripts in the latest MS1101 package
Checking the gradients of velocity and turbulent kinetic energy
Computed grad(U) and grad(k) additionally from checkpoints 1,800, 1,950 and 2,000 using postProcess of OpenFOAM 2512 with the same fvSchemes . The operator grad returns a vector when given a scalar field and a tensor when given a vector field, according to OpenFOAM 2512 API We compared all components of the gradient fields between checkpoints, not only the magnitudes, so as not to discard changes in direction:
ΔgU = || grad(U)b − grad(U)a ||F [1/s]
Δgk = | grad(k)b − grad(k)a | [m/s²]
Radial band share = Σ(V · Δg²)band / Σ(V · Δg²)whole domain
| Iteration range | Gradient | Volume-weighted RMS of the change | Cell-count p95 of the change | Share in r = 0.15–0.18 m |
|---|---|---|---|---|
| 1,800→1,950 | grad(U) | 0.1617 s⁻¹ | 0.2210 s⁻¹ | 97.75% |
| 1,800→1,950 | grad(k) | 0.3657 m/s² | 0.02184 m/s² | 99.90% |
| 1,950→2,000 | grad(U) | 0.06027 s⁻¹ | 0.1768 s⁻¹ | 94.00% |
| 1,950→2,000 | grad(k) | 0.09538 m/s² | 0.01686 m/s² | 99.65% |
Most of the gradient change occurs in the 0.15–0.18 m radial band, as with the differences in Ux/k The locations of highest gradient change that recur in both windows are near cells 375687 and 375631 at r ≈ 0.15365 m, z ≈ 0.00929 m, with non-orthogonality ≈ 25.3°. However, the cells in the top 1% of the whole grid ranked by non-orthogonality or skewness together contribute less than 0.0018% of the squared gradient difference. This result identifies only where the gradients change between checkpoints; it does not prove whether mesh quality is or is not the cause of the residual cycle.
Volume-weighted RMS and cell-count p95 use different weightings, so the RMS of grad(k) may appear much higher than the p95 when the change is concentrated in small-volume cells. The checkpoints are 50 or 150 steady SIMPLE solver iterations apart, which is not the actual time of air flow. Importantly, grad(U/k) is not a local equation residual: the recorded residual is an aggregate value from the linear solver, so we still need to instrument the equations exactly according to the definition if we want a spatial residual map and to find the cause of the pattern Ux/k
Reproduce with extract_checkpoint_gradients.sh, analyse with analyze_checkpoint_gradients.py and generate the images with plot_checkpoint_gradient_changes.py; the ZIP contains logs, SHA256 provenance, CSV/JSON, tests and code, without the large gradient fields or the mesh.
Local equation residual maps and wake-line probes
In a separate diagnostic copy, we enabled solverInfo of OpenFOAM 2512 together with writeResidualFields while keeping the original fvSolution and fvSchemes , then continued from checkpoint 2,000 to 2,100 to record the local initial residuals of the equations Ux, Uy, Uz, p, k, omega every 10 iterations, 60 maps in total, on the 399,881-cell mesh. A map is the row-wise residual of the linear system before each equation is solved, whereas the usual residual history is an aggregate norm that the solver normalizes according to the matrix and the solution method, following OpenFOAM solverInfo and the OpenFOAM residual definition
For the recorded maps, the r = 0.15–0.18 m band accounts for about 60.9% of the sum of absolute residual-row values in Ux and 81.3% in omega; while k is about 75.2%. The maps of Ux and k normalized to equal L1 sums have almost repeating shapes between iterations 2010 and 2100 (L1 distances of about 6.8 × 10⁻⁷ and 1.2 × 10⁻⁷ respectively), while the global initial residuals of the two equations stay almost unchanged at 9.30 × 10⁻⁶ and 9.60 × 10⁻⁶ respectively. This helps identify the spatial pattern and its recurrence over the measured window, but it does not prove that the radial band or mesh quality causes the cycle, because these are unweighted algebraic rows, not volume-weighted, and not residuals of the nonlinear SIMPLE outer iteration that could be decomposed by cause.
We placed 24 probe points from the radial range and wake line of interest, plus upstream references and gradient hotspot points, then ran postProcess with the function object probes at iterations 2000, 2050 and 2100, following the OpenFOAM probes manual At 24/24 downstream points along −z, Uz < 0 at every checkpoint, which is consistent with air being induced to move opposite to the force on the propeller, which is +z. The centreline axial velocity at z = −0.16 m is about −6.20 m/s at iteration 2100, but this is a value from a steady solver field, not a real measurement or a validated representative wake velocity. The probe points use cell interpolation, so they are not a continuous streamline.
The residual maps, probe points, summary results, metadata and analysis scripts are in the workbook; the raw mesh and large fields are not included. The iteration values are steady SIMPLE solver iterations, not real flow time. Both checks therefore only help point to regions and check the sign of the flow direction in the model; they neither close the residual cycle nor confirm physical accuracy.
NASA recommends monitoring both residuals and engineering quantities, because they may converge at different rates, while OpenFOAM states that residuals depend on the solver and the normalization method. These sources help interpret the computation history, but we do not change the screening criteria of the training set based on this evidence (NASA: iterative convergence, OpenFOAM: residuals).
Download the latest MS1101 package to view sensitivity-simplec-study.csv/json, checkpoint fields and gradient diagnostics, log/provenance, wall-resolution.json and wall-yplus.csv including the cases that did not pass the criteria. The analysis code reports candidate lag values only to help read the pattern, without concluding a cause, and the difference checker still rejects cases whose residual window is incomplete or whose physical settings do not match.
Checking the rotating frame against an analytical solution before using it for propellers
To separate MRF setup problems from the complexity of the propeller, we built a fluid problem between two concentric cylinders: the inner cylinder of radius 1 m rotates at 1 rad/s and the outer cylinder of radius 2 m is stationary, with ν = 0.1 m²/s and a two-dimensional field without axial flow or cylinder end effects. The problem follows OpenCFD Rotating cylinders while the files and run results in this package were created by us.
For steady, laminar, axisymmetric flow, the tangential velocity equation reduces to:
d²uθ/dr² + (1/r) duθ/dr − uθ/r² = 0
uθ = A r + B/r
uθ(1 m) = 1 m/s, uθ(2 m) = 0
A = −1/3 s⁻¹, B = 4/3 m²/s
For example, at r = 1.5 m, uθ = 7/18 ≈ 0.388889 m/s We computed it from the CFD field using uθ = (−yUx+xUy)/r to preserve the sign of the rotation direction, then compared it with this solution at the same 19 points inside the domain.

| Number of cells | RMS velocity error (m/s) | Iterations to convergence |
|---|---|---|
| 256 | 0.00897463 | 144 |
| 1,024 | 0.00229790 | 386 |
| 4,096 | 0.000583085 | 1,324 |
When the resolution in the radial and circumferential directions is doubled, the error decreases by almost four times. The observed order computed with p = log(e_coarse/e_fine)/log(2) is 1.966 and 1.979 This value includes the effect of sampling at the sample points, so it is not the error of every cell in the domain. The fine case has a maximum error of about 0.0995% of the inner cylinder speed of 1 m/s
Download the three-grid MRF verification package with code and actual results The results and Python tests can be opened on Windows/Linux; OpenFOAM can be rerun on Ubuntu or on Windows via WSL as described in the README. Passing this package verifies only the specified laminar rotating-frame problem; it does not certify the turbulence model or propeller performance.
Exercise: why does a fourfold reduction in error give an order of about two? Because log(4)/log(2)=2. Try calculating with the actual values in the table, then explain why the result is not exactly two.
Evidence from the trials before a converging method was found

This graph shows results we ran ourselves unlike the graph above comparing the source results. It uses the MS1101 surface from ENOLA and computes forces from pressure plus viscous contributions; no experimental thrust was input to force the results. Open the full-size graph
What the experimental package can already do
Generate a mesh around the real propeller and run OpenFOAM 2512 as steady MRF / k-omega SST at 5088 RPM while recording thrust, torque, residuals and yPlus. ρ = 1.225 kg/m³ and ν = 1.5 × 10⁻⁵ m²/s were chosen as simulation assumptions which have not yet been confirmed to match the ENOLA test conditions.
The surface keeps its original coordinates, removing only 2 zero-area triangles out of 671,620 faces, then checking surface closure and normal directions before meshing. The package checks the hashes of the archive and OBJ before reading, and the download does not include a copy of the source geometry or OpenFOAM.
Download the MS1101 run package with CFD evidence for Ubuntu 24.04 amd64 or Windows via WSL Ubuntu 24.04 It includes a README with run steps and check results for each case. ENOLA must be downloaded separately from its owner, and a new output folder name must be used each time.
How to read the results without concluding beyond the evidence
Finishing the set number of iterations does not equal convergence. We check the last 100 iterations: the mean changes by less than 1% between the first and second halves and the max–min range is less than 2% of the mean, for both thrust and torque, with the initial residuals of all six variables below 10⁻⁵. This is a numerical screening criterion for the exercise, not a certificate of physical correctness.
The 85,289-cell grid at iteration 800 gives a final-iteration thrust of about 2.5165 N but the thrust over the last 100 iterations still fluctuates over a range of about 14.12% of the mean, while the 156,104-cell grid gives about 2.7336 N with a fluctuation range of 8.83% so they have not converged. The final-iteration number should not be put into DroneSim as confirmed performance.
When relaxation was reduced and the 156,104-cell grid was run on to iteration 1600 the thrust fluctuation over the last 100 iterations dropped to about 1.24% and passed the plateau criterion for both forces, but the maximum residual was still about 8.42 × 10⁻⁴ so it has not yet passed the combined criteria This example shows that a force graph that merely looks steadier is not sufficient.
The study of a third grid, a larger domain and reduced relaxation is recorded in results/*/summary.json and in the graph above:
| Case in the download package | Number of cells | Last iteration with forces | Status |
|---|---|---|---|
| coarse, initial grid | 85,289 | 800 | Did not pass the convergence criteria |
| fine, increased surface resolution | 156,104 | 800 | Did not pass the convergence criteria |
| finer, further refinement | 399,881 | 358 | Stopped before completion; no evidence of a finished run |
| finer-resumed, continued in a separate copy | 399,881 | 800 | Run completed, but did not pass plateau and residual criteria |
| domain, enlarged computational box | 234,113 | 800 | Continued from checkpoint; not yet passed the criteria |
| relaxed, reduced relaxation of fine | 156,104 | 1,600 | Passed plateau but not residuals |
The finer case has yPlus values from the checkpoint at iteration 350, so we do not claim them as iteration 358 values, and we have not concluded the cause of the stop from the available evidence. Adjusting relaxation changes the solution method; it does not adjust the density or forces to fit the experimental data.
Update 1.12.6: the finer grid was successfully continued from checkpoint 350 to 800 in a separate copy without changing the mesh or conditions. The final-iteration thrust is 2.8932 N and the torque 0.08292 N·m, but the thrust over the last 100 iterations still has a fluctuation range of 12.33% and a maximum residual of 1.37 × 10⁻³ so it has not converged. The yPlus values at iteration 800 are about 1.10–64.48 (mean 16.76). Completing the run closes a processing gap but does not make the validation pass automatically.
Additional checked continuation results: we continued the relaxed case from iteration 1,600 to 3,200 checking that the geometry and settings in 24 files were unchanged, changing only endTime. The program finished normally with T ≈ 3.02979 N, Q ≈ 0.0948042 N·m but the thrust over the last 100 iterations has a fluctuation range of 5.13% and a maximum residual of 7.76 × 10⁻⁴ so it has not passed either the force or the residual criteria. The window that looked steady at iteration 1,600 did not persist when the run was longer. The results of the set relaxed-3200 and the provenance are included in the ZIP.
Important limitations: the mesh does not yet have prism layers and yPlus is spread over several ranges; first-order upwind convection is used; oscillation over SIMPLE iterations is not oscillation in the propeller's real time. Even with several grids, grid independence, Richardson extrapolation or GCI cannot be claimed while the results have not converged.
The path toward a model that can be validated
- Check the near-wall layer and sensitivity to mesh/boundaries, together with the consistency of the rotation axis and forces. If steady MRF still does not converge, study a transient case with sufficient timestep and averaging window.
- Request the test conditions, normalization definitions, installation details and uncertainty from the data owner, and keep them separate from the values assumed in the CFD.
- Only after passing the numerical checks should T/Q and the coefficients be compared at the same rotational speed and conditions, with uncertainty, before passing values through the adapter into DroneSim.
This package is therefore ready for practising runs and analysing why the results are not yet reliable while propeller performance has not been confirmed. Do not use these results for real flight decisions.
Additional information from reviewing the research and reporting methods
We also reviewed the ENOLA team's ICAS 2024 paper and found that it uses a different propeller model from the MS1101, so the calibration data and sampling methods of that work are not carried over as metadata for this dataset. The related AST paper states that data can be requested from the researchers. This round of searching has not yet confirmed the atmospheric conditions or uncertainty of the MS1101 rows used for validation.
NASA recommends examining both residuals and the engineering quantities of interest. Steady force values and converged equations may occur at different times. The 10⁻⁵ criterion in the training package is a criterion we declared, not an international standard value endorsed by NASA for every case.
We later found the full AST paper published by the authors which contains an uncertainty table for the force balance, but it concerns yet another propeller experiment, so we added questions about the balance, calibration, axes and coverage factor to the data request instead of applying the values from that table to the MS1101 directly.
The yPlus values in this package use the default useWallFunction = true according to OpenFOAM 2512 so they must be read together with the selected wall function and are not always a direct check of shear from the flow field. Meanwhile, kOmegaSSTLM supports laminar-to-turbulent transition, but it requires additional variables and conditions to be prepared. The turbulence intensity formula that divides by the inlet velocity cannot be used directly with the zero velocity of hover, so we have not switched models and claimed that the problem has disappeared.
Preparing uncertainty before comparing CT and CP

The figure uses values from uncertainty-example.json to show how much each input contributes to the variance. When the values or uncertainties change, the shares change too. No ENOLA measurements are included in this example. Open the full-size graph
When CT = T/(ρn²D⁴) and CP = 2πQ/(ρn²D⁵) with n = RPM/60, if the inputs are independent and the uncertainties are small enough for a first-order approximation, we obtain:
u(CT)/CT = √[(u(T)/T)² + (u(ρ)/ρ)² + (2u(n)/n)² + (4u(D)/D)²]
u(CP)/CP = √[(u(Q)/Q)² + (u(ρ)/ρ)² + (2u(n)/n)² + (5u(D)/D)²]
u is the standard uncertainty, not automatically the maximum error from a specification. If variables are correlated, covariance must be included according to NIST TN 1297 guidance An easy mistake is to compute P = 2πnQ and then treat P and n as independent again, so the formula should first be reduced to Q and n, as shown above.
Hypothetical example for learning: if only u(D)/D = 1% and the other inputs have no uncertainty, the formulas give u(CT)/CT = 4% and u(CP)/CP = 5%. This shows the sensitivity to diameter, not ENOLA's measured uncertainty.
The Python package for comparing ENOLA now includes uncertainty.py and uncertainty-example.json . Run python uncertainty.py uncertainty-example.json new-result.json with all examples labelled as hypothetical. The tool does not fill missing values with zero, does not assess model bias, and does not declare validation results automatically.
Comparison with the real test row at 5,088 RPM
We inspected the 0° test file for the MS1101 in the UPV ENOLA v1 database, which is recorded exactly at the hover point 5,088 RPM, V = 0 m/s so no interpolation between rotational speeds is needed. The measurements in this row are T = 4.6688 N, Q = 0.05954 N·m and shaft power P = ΩQ = 31.72 W; the CQ value in the original is NaN so it keeps its missing status and is not replaced with zero (Source data and downloads, data usage rights conditions).

The CFD points compared have passed the package's numerical check criteria, but assume ρ = 1.225 kg/m³ and ν = 1.5 × 10⁻⁵ m²/s, because the test file checked does not specify per-point atmospheric conditions for matching. We report signed differences using 100 × (CFD − experiment) / experiment and compute power from P = ΩQ, Ω = 2π(RPM/60):
| Case that passed the numerical criteria | CFD thrust (difference) | CFD torque (difference) | CFD shaft power (difference) |
|---|---|---|---|
| ENOLA measurement at 5,088 RPM | 4.6688 N | 0.05954 N·m | 31.724 W |
| L5 reference, 156,104 cells | 3.38252 N (−27.55%) | 0.084847 N·m (+42.50%) | 45.208 W (+42.50%) |
| L4 coarse, 85,289 cells | 3.18582 N (−31.76%) | 0.086127 N·m (+44.65%) | 45.890 W (+44.65%) |
| L5 domain enlarged 1.5 times | 3.32664 N (−28.75%) | 0.084954 N·m (+42.68%) | 45.265 W (+42.68%) |
| coarse co-refinement · surface/rotor/wake 4/2/1 · 85,289 cells | 3.18580 N (−31.76%) | 0.086127 N·m (+44.65%) | 45.890 W (+44.65%) |
| medium co-refinement · surface/rotor/wake 5/3/2 · 310,153 cells | 3.10980 N (−33.39%) | 0.081360 N·m (+36.65%) | 43.350 W (+36.65%) |
| fine co-refinement · surface/rotor/wake 6/4/3 · 1,862,335 cells | 4.43316 N (−5.05%) | 0.090506 N·m (+52.01%) | 48.223 W (+52.01%) |
The L4/L5 and enlarged-domain differences are sensitivity results a different question from comparison with experimental data: the L4→L5 pair changes thrust by 5.82% and torque by 1.51%; enlarging the L5 domain changes thrust by 1.65% and torque by 0.125% relative to the L5 reference. The existing L6 set is not in the table because its residuals passed in only 48/100 of the last iterations; even though the forces were steady, it does not meet the project's result-acceptance criteria.
The co-refinement study increases the blade-surface/rotor-zone/wake levels together from 4/2/1 to 5/3/2 and 6/4/3 while keeping the domain, physics and schemes unchanged. All three grids passed checkMesh, force plateau, solver-end and the 100/100 residual window; the fine case ran OpenFOAM 2512 with Open MPI 4.1.6 on 16 ranks using about 3.7 GB of memory on WSL. The key point is that the solutions do not change in the same direction: from coarse to medium, T changes by −2.39% and Q by −5.54%, but from medium to fine, T reverses by +42.55% and Q by +11.24%, even though on the fine grid the forces are very tightly steady over the last 100-iteration window. This result is evidence of non-monotonic grid sensitivity not grid convergence.
The tool therefore deliberately does not compute or report Richardson extrapolation/GCI for either thrust or torque. Having three grids on which the solver passes is not sufficient on its own; if the solutions are not ordered and the asymptotic range cannot be identified, applying the GCI formula to these data would yield misleading numbers. NASA recommends at least three levels to estimate the order and check the asymptotic range before using extrapolation/GCI (NASA NPARC: spatial convergence); the standard procedure for reporting discretization uncertainty is described by Celik et al. (ASME J. Fluids Engineering, 2008).
Conclusions that can be drawn now: the solver fine case passes the numerical gates and the thrust approaches the test point, but the torque is still 52.01% higher than measured and the co-refinement results are non-monotonic, so grid uncertainty cannot yet be concluded and only a quantitative preliminary comparison is possible, this is not yet formal physical validation, and the numbers must not be used to predict performance or plan missions. Passing iterative convergence is a different matter from spatial convergence; grid ordering and the asymptotic range must be checked separately (NASA: iterative convergence, NASA: spatial/grid convergence).
The 21-row 0° test file and the calculated results, traceable by hash, are in the MS1101 measurement comparison dataset; it contains CSV, JSON, scripts and a description of the sources, citing ENOLA CC BY-SA 4.0. The simulation package can be reproduced separately from MS1101 CFD workbook using Python and OpenFOAM 2512 as described in the README.
The ENOLA data describe testing in the Francisco Payri wind tunnel with a custom force/moment balance, with load cells read through a National Instruments DAQ system; the project page gives the tunnel size as 2.8 × 2.8 × 22 m and the maximum wind speed as 40 m/s (ENOLA test rig, project facilities). However, the sources checked do not specifically match this information to the MS1101 row at 5,088 RPM, and they do not give per-point uncertainty/calibration, the atmospheric conditions at the time of measurement, or evidence that the OBJ is the same specimen as the test article. General test-rig details must therefore not be substituted for per-point metadata. We do not create error bars or borrow uncertainty from a different propeller model.
Checking the blade surface: where does the force difference come from?
When the results of three grids do not converge toward the same value, we should look back at what the grids represent. This check reads the surface face coordinates and the fields saved at iteration 4,000, identical for all three grids and then integrated the pressure force again. The result matches the pressure force in the OpenFOAM log within a relative check tolerance of 10⁻⁸, confirming that the tool reads the data and force directions consistently, but it does not yet show that the model matches the experiment.

| What was checked at iteration 4,000 | Coarse 4/2/1 | Medium 5/3/2 | Fine 6/4/3 |
|---|---|---|---|
| Number of blade surface faces | 4,016 | 15,532 | 62,055 |
| Surface area (m²) | 0.0108154 | 0.0106906 | 0.0106680 |
| Volume enclosed by the grid, difference from the source OBJ | −0.722% | −0.619% | −0.174% |
| Area-weighted mean y⁺ | 36.63 | 29.77 | 20.15 |
| Area in the range 5 ≤ y⁺ < 30 | 54.77% | 69.07% | 78.39% |
| Pressure thrust (N) | 3.19119 | 3.11852 | 4.44458 |
| Viscous thrust (N) | −0.00539 | −0.00869 | −0.01142 |
Reading the graph: the upper bars show the actual area covered by each y⁺ range, which differs from the face-count statistics in the earlier case study. The lower lines sum the pressure thrust in annuli 0.1R wide, with R = 0.140144 m according to the imported geometry. The total pressure force differs between the fine and medium grids by 1.32606 N; in the outer half of the blade (r/R ≥ 0.5) the difference is 1.02623 N, or about 77.4% of this difference. The increase in total thrust therefore comes mainly from pressure, not directly from an increase in viscous force. However, wall treatment can change the velocity and pressure fields through the coupled solution of the equations, so its role cannot yet be ruled out.
The formulas used for re-checking are as follows:
- Area-weighted mean ȳ⁺ = Σ(Aᵢyᵢ⁺) / ΣAᵢ where Aᵢ is the magnitude of the area vector of face i in m²
- Pressure force Fₚ = ρ Σ(pₖᵢSᵢ) where pₖ is pressure divided by density in m²/s², which is the value stored in the file
pfor this incompressible case; Sᵢ points out of the fluid into the blade, and ρ = 1.225 kg/m³ - Pressure moment Mₚ = Σ[(cᵢ − c₀) × (ρpₖᵢSᵢ)] in N·m; cᵢ is the face centre and c₀ = (0,0,0) is the original reference centre
Practice example: two surface faces have areas of 1 and 3 mm² and y⁺ values of 10 and 30 respectively. Counting faces gives a mean of 20, but area weighting gives (1×10 + 3×30)/(1+3) = 25 so the averaging method must be stated before comparing numbers.
A volume closer to the OBJ helps check the overall geometry but does not confirm the resolution at the leading edge, trailing edge or near-wall layer. This grid set still has about 29,000–31,000 level-0 cells in the far field, even though the propeller and wake regions are finer, so it is local co-refinement not a reduction of grid spacing in all regions by a single ratio. NASA explains that a grid study must treat the near-wall spacing, boundaries and connecting regions systematically, not rely on the total cell count alone (NASA: grid considerations)
The 5–30 range in the table is an analysis bin, not an automatic acceptance or failure criterion. We use yPlus values computed through the wall function as stated in the previous section. This evidence points to checking wall treatment together with the near-wall grid layers and the geometric representation before building a new grid set. The OpenFOAM manual describes adding layers of cells along the surface in addLayersControls and the choice of absolute/relative thickness, which requires checking the number of layers actually generated and the quality afterwards (OpenFOAM: layer addition)
Open surface-faces.csv to see per-face values, surface-audit.json to see the mesh/field hashes, and surface-family-summary.csv to see the summary table in MS1101 CFD workbook Reading the fine field, which was run in parallel, uses reconstructPar -time 4000 -fields '(p yPlus nut)' before analysis; the original solver results were not modified.
Testing the wall function with a control case
To test the near-wall layer hypothesis, we split a copy of the medium grid from checkpoint 4,000 into two cases and ran both serially with OpenFOAM 2512 to 4,500. The control case uses all the original values, while the test case changes only nutkWallFunction as nutUSpaldingWallFunction in the field nut; the grid, rotational speed, fluid, omega wall function and solution method are unchanged, with before/after file hashes to confirm the scope of the change.
The Spalding wall function uses velocity to build a turbulent viscosity relation that is continuous down to the wall, instead of the original evaluation through k. This choice is a one-variable sensitivity experiment not a claim that it is better suited to this propeller (OpenFOAM: nutUSpaldingWallFunction). The results must pass residuals for all equations over the last 100 iterations and force steadiness under the same criteria before being reported as a converged comparison, and the method for computing yPlus after changing the wall function must be stated, because the expression used for evaluation changes with the model.
| Results for iterations 4,401–4,500 | Control: original nutk | Test: Spalding |
|---|---|---|
| Residuals of all equations below 10⁻⁵ | 100/100 iterations | 0/100 iterations |
| Maximum residual in the window | 6.68 × 10⁻⁷ | 2.56 × 10⁻⁵ |
| Force and torque steadiness criteria | Passed | Passed |
| Mean thrust in the window (N) | 3.10983 | 3.08281, diagnostic only |
| Mean torque in the window (N·m) | 0.0813598 | 0.0831889, diagnostic only |
| Accepted as a converged result | Yes | Not yet |
Lessons from the actual results: changing the wall function forces the solver to re-adjust the fields. Even though the forces looked steady, the test case did not pass the residuals within the specified 500-iteration window. We therefore do not report the percentage difference as a converged wall-model effect, do not conclude that Spalding fixes the non-monotonic response, and do not choose it because its forces are closer to the experimental data.
Understanding the three tolerance levels before adjusting the solver
The phrase “the computation has converged” must specify which level is meant. In this example there are at least three levels whose values should not be compared directly:
- Inside the wall function: finds the friction velocity uτ that makes the near-wall relation consistent, iterating with the Newton–Raphson method.
- Inside the linear solver: solves the system of equations assembled in that iteration, such as Aφ = b; solving this system well does not mean that all the fields are consistent yet.
- Between SIMPLE iterations: adjusts velocity, pressure and turbulence variables together. This project checks the initial residuals of all six equations at every iteration over the last 100 iterations, and checks force steadiness as an additional condition.
For Spalding, the basic relation is
y⁺ = u⁺ + [exp(κu⁺) − 1 − κu⁺ − (κu⁺)²/2 − (κu⁺)³/6] / E
u⁺ = Urel / uτ y⁺ = y uτ / ν uτ = √(|τw| / ρ)
Urel is the magnitude of the relative velocity used in the wall model, y is the distance from the wall, ν is the kinematic viscosity, τw is the wall shear stress and ρ is the density, while κ and E are constants of the wall law; y⁺ and u⁺ are dimensionless. This equation helps close the model near the wall but does not replace the Navier–Stokes equations for the whole field. See the details and limitations in the OpenCFD Spalding documentation
Unit example: if uτ = 0.6 m/s, y = 0.0005 m and ν = 1.5 × 10⁻⁵ m²/s, then y⁺ = 20. If Urel = 6 m/s, then u⁺ = 10. These numbers are for substitution practice only; they do not confirm that this pair is a solution of the Spalding equation or that it suits our grid.
The version actually used must be checked: the table in the 2312 manual gives a default tolerance of 0.0001, but the constructor source of version 2512 specifies 0.01 and maxIter 10, so numbers should not be copied from a manual across versions without checking. The documentation also explains that restarting with this condition may give slightly different nut values, and gives an example of tolerance 10⁻⁷ and maxIter 100 for stricter internal computation. This is guidance for setting up a separate experiment, not evidence that the current problem is caused by the tolerance or that adjusting it will certainly make the case pass.
Practice separating the issues: if the thrust changes by only 0.1% but the initial residual of Uz is still above the criterion, can the result be accepted? Under this protocol it cannot, and increasing the wall function's maxIter is not the same as increasing the number of SIMPLE iterations. Record clearly which variable is being changed.
Does it pass with more iterations? Test results up to iteration 6,000
We restarted both cases from the same checkpoint 4,000, set the stop at 6,000 before starting the run, and used OpenFOAM 2512 in parallel with the same 8 ranks according to OpenCFD guidance keeping the grid, equations, other boundary conditions and acceptance criteria unchanged. Comparisons must therefore be made within this new pair of experiments; the difference between serial and parallel runs is not treated as a physical result.

| Criteria and results for 5,901–6,000 | Original wall function | Spalding |
|---|---|---|
| Residuals passed for all equations | 100/100 iterations | 100/100 iterations |
| Maximum initial residual in the window | 6.403 × 10⁻⁷ | 1.049 × 10⁻⁶ |
| Mean thrust | 3.109609 N | 3.078787 N |
| Mean resisting torque | 0.0813582 N·m | 0.0831646 N·m |
| Force steadiness and mesh criteria | Passed | Passed |
Conclusions: both cases in this pair have now passed the project's numerical criteria. On the same medium grid, switching to Spalding reduces thrust by 0.991% and increases torque by 2.220% using the formula Δ% = 100 × (test value / control value − 1). This value is wall-model sensitivity on a single grid It does not prove that the inconsistency among the three grids has been resolved, it is not an uncertainty value, and it is not yet confirmation of agreement with the real experiment.
Reading the graph correctly: the upper line is the highest initial residual of the six equations at each iteration, the dashed line is the 10⁻⁵ criterion, and the shaded area is the last 100 iterations specified before the run. The horizontal axis is SIMPLE iterations, not seconds of real flight. Seeing the line below the criterion only in some ranges is not enough; the two force graphs help check the answers we will use as well.
Traceability: the solver wrote End completely for both cases at 6,000, and the force and residual histories were re-checked successfully. The original wrapper script failed after the solver finished because a file was edited while it was still running, so wrapper exit 1 is recorded as it happened and not replaced with a success status. The script was fixed to hand over execution with exec and a new, separate short test run gave exit 0. This incident is not mixed with the physical values or the acceptance criteria.
Download the Wall-function study evidence and graphs for all history CSVs, logs, input hashes, run status and graph-generation code. The original serial results at 4,500 remain in results/wall-trial/ and still have a qualified delta of null; the new set is kept separately in results/wall6000/ to preserve the history of both passing and failing results.
Near-wall grid layers: 8 layers requested, how many were actually obtained?

Close to the blade surface, velocity changes rapidly over a short distance, so we tried adding thin cells arranged along the surface, called layer mesh before solving the flow equations. This set uses OpenFOAM 2512 and copies of the three original grid levels, keeping the original grids. The target is 8 layers with a thickness expansion ratio of 1.2 and first-layer thicknesses of 100, 50 and 25 micrometres respectively.
We compared two methods of moving the grid to make room for the new layers: displacementMedialAxis which is the default, and displacementMotionSolver which solves a mesh-motion equation. The latter also requires settings in fvSolution and fvSchemes according to the OpenCFD manual on layer addition The following results come from the logs of actual runs, not values expected from the manual.
| Original grid | Mesh motion method | Cells after generation | Surface faces where layers were generated | Mean number of layers | Passed mesh generation criteria |
|---|---|---|---|---|---|
| Coarse | Medial axis | 94,891 | 88.23% | 2.45 | Failed |
| Coarse | Motion solver | 96,377 | 95.31% | 2.82 | Passed |
| Medium | Medial axis | 379,974 | 93.26% | 4.53 | Failed |
| Medium | Motion solver | 384,364 | 96.06% | 4.81 | Passed |
| Fine | Medial axis | 2,254,693 | 96.91% | 6.35 | Passed |
| Fine | Motion solver | 2,258,175 | 97.94% | 6.40 | Passed |
Criteria declared before the runs: checkMesh must pass, no more than 3 million cells, and layers must be generated on at least 95% of the requested surface faces. The 95% criterion is a screening criterion of this project. All six cases passed checkMesh but two cases failed the coverage criterion; we keep those results as well.
The statement 95.31% does not mean that 95.31% of the surface has all 8 layers because it counts faces where layers were generated at least partially, it is not area-weighted, and the actual mean for the coarse grid is only 2.82 layers. Looking only at the message Mesh OK or the value nSurfaceLayers 8 is therefore not sufficient. This set has not yet solved the flow equations on the layered grids, so there are no new force or yPlus results yet.
Compute the thickness before generation, then check the values actually obtained
Let the first-layer thickness be t₁, the expansion ratio r and the number of layers n:
tᵢ = t₁rⁱ⁻¹ and H = t₁(rⁿ − 1)/(r − 1) when r ≠ 1; if r = 1, then H = nt₁
Medium grid example: t₁ = 50 µm, r = 1.2, n = 8 gives a design total thickness of H ≈ 0.825 mm but the Motion solver log reports a total thickness of about 0.679 mm with a mean of 4.81 layers. Both reported values indicate that the actual generation was truncated. The mean number of layers should not be substituted back into the series in the expectation of matching the reported thickness at every point.
For cells nearly perpendicular to the surface, the first-layer centre distance may be approximated as y₁ ≈ t₁/2 to begin planning y⁺ = y₁uτ/ν but uτ must be obtained from the wall shear stress after solving the equations, so an expected yPlus must not be called a checked value.
Refining the whole domain: why the grids actually generated must be checked
We fixed the geometry, the 0.84 m domain and the surface/rotor/wake refinement levels 5/3/2, changing only the number of base cells N, and then used h = 0.84/N with a first-layer height of t₁ = 50 µm × 32/N The same criteria for every protocol are: checkMesh passes, no more than 3 million cells, and layers generated on at least 95% of the requested surface faces.
| N / protocol | Cells | coverage by face count | Mean layers out of 8 | Construction result |
|---|---|---|---|---|
| 24 · v1 | 100,682 | 0.00% | None | Failed; skewness 4.517 |
| 28 · v2 | 286,141 | 96.02% | 4.58 | Failed; skewness 4.738 |
| 30 · v3 | 340,769 | 95.81% | 4.74 | Passed |
| 32 · v3 | 384,364 | 96.06% | 4.81 | Passed |
| 36 · v3 | 529,897 | 96.51% | 5.15 | Passed |
| 44 · v3 | 921,354 | 96.72% | 5.64 | Passed |

N=28 passed the coverage share but failed checkMesh so it had to be excluded under the original protocol. We then registered protocol v3 before running the new set, without adjusting thresholds; N=30/32/36/44 all passed the construction gate according to the logs and have complete mesh-hash evidence. The coverage value counts faces, is not area-weighted, and means that layers exist partially; it does not mean each face has all 8 layers.
The solve step has been completed for all four grids: all four grids start from the same initial fields, using OpenFOAM 2512 simpleFoam/steady SIMPLE, Open MPI 4.1.6 with 8 ranks up to iteration 6,000 and the same residual/force/y⁺ criteria. If the launcher hits a time limit, the run continues from the latest checkpoint without changing the equations or criteria, and logs/hashes are kept separately by segment according to protocol addendum The checks found that only N32 passed all criteria, so the results are not accepted as qualified grid sensitivity and Richardson/GCI is withheld. Grid screening alone is neither a force result nor physical confirmation against ENOLA.
What is a checkpoint? It is a saved flow field used to resume computation. For example, if a job stops during iteration 1,167 but the last complete write was at 1,150, it resumes from 1,150, after checking that all 8 parts of the files are from the same iteration and complete. A resumed run must still pass the same criteria, and it is not guaranteed to be bit-for-bit identical to an uninterrupted run, because ASCII data store a limited number of digits. Read the notes on checking checkpoints and accepting results
Checked results: N30 and N32 ran the full 6,000 iterations, have complete checkpoints for all 8 ranks and both passed the mesh and force steadiness checks, but their residual results differ:
| Grid | Final iterations in which residuals passed for all equations | Maximum residual over the last 100 iterations | Mean thrust (N) | Mean torque (N·m) | Acceptance result |
|---|---|---|---|---|---|
| N30 | 0/100 | 5.029×10⁻⁵ | 3.877983 | 0.104284 | Failed; force values for diagnosis only |
| N32 | 100/100 | 2.458×10⁻⁶ | 2.956402 | 0.0926844 | Passed the numerical criteria for this case |
| N36 | 0/100 | 7.301×10⁻³ | 2.702727 | 0.0918554 | Failed residuals and force steadiness; diagnostic only |
| N44 | 0/100 | 2.449×10⁻⁵ | 3.309027 | 0.0882917 | Failed residuals; diagnostic only |
This is an example showing that steady forces do not replace checking the residuals of the entire field Since N30 has not passed, the N30–N32 force difference is not used as confirmation of grid sensitivity. Even though N32 passes all criteria for a single case, this still does not confirm grid independence or agreement with the real experiment.
Final results for all four grids

Open the full-size graph · Summary report of results and limitations · Getting-started guide for the download package
The planned runs are complete, but grid independence is not yet confirmed: N32 passes the per-case criteria, while N30/N36/N44 fail the residuals and N36 also fails force steadiness. The shared inputs and protocol were checked and match, but this does not compensate for the failing cases, so no qualified grid sensitivity or GCI is reported.
N44 has a force fluctuation range of only 0.00378% and a torque of 0.01582% but the maximum residual of 2.449×10⁻⁵ exceeds the 10⁻⁵ criterion, making it another example that both the field and the quantities to be used must be checked. This result is not formal physical validation against ENOLA.
Beware of comparing grids that are too close together: the N30→N32 pair has a spacing ratio r = h₃₀/h₃₂ = 32/30 ≈ 1.067 whereas NASA recommends r of at least 1.1 to help separate grid effects from other errors. A small force difference in this single pair therefore does not mean the model is accurate. We keep all grids as planned and consider the whole sequence before drawing conclusions.
Try it yourself: download the Layer mesh package: code and run evidence to compare the summary with the per-case logs. Read the protocol v2, protocol v3 and screening results report v3 The source geometry data must be obtained separately under ENOLA's rights terms; the download package does not include the geometry or self-generated experimental results.
Exercise: if t₁ is halved while r and n are kept the same, how does H change? The answer is that it halves, but it cannot yet be concluded that yPlus or the force error will halve, because the equations must be solved and the flow field checked first.
Do not confuse fitting with verification: in the GCI tool, fitting the order p from three points and then testing the same three points for consistency is only a check of the calculation, not independent evidence that the asymptotic range has been reached. The code therefore separates richardson_fit_consistency_ratio from asymptotic_range_verified which is still false and requires further grid work/evidence. The existing three-grid MS1101 results are still rejected before the fitting step because they are not monotonic.
Review exercises and suggested answers
Problem: in the hypothetical example, if n is increased to 200 rev/s with ρ and D fixed and CT, CP assumed unchanged, what are T and P? Which assumptions must be re-checked?
Suggested answer: T increases fourfold to 7.84 N and P increases eightfold to 156.8 W, but Reynolds number, tip Mach number, J and the data range must be checked, because the coefficients may not be constant. Multiplying according to the formula does not extend the validation range.
What is ready to use are the formulas, recording templates, adapter code, reference geometry data, the MRF verification package against an analytical solution, and the MS1101 case that can be compared with the test data exactly at the 5,088 RPM row, with convergence and sensitivity evidence separated by grid/domain. See the reproducible files in the ENOLA comparison dataset and CFD experimental package; the differences found have not yet passed physical validation with uncertainty, because test-point metadata and specimen traceability are still missing. Multi-angle models and angular rates for general flight also remain future work. Go back to check the CFD process or review the lesson overview
Reading CFD results properly: completing the computation does not mean passing
The following N36 case is an actual result that ran the full 6,000 iterations but did not pass the criteria. Use it to learn how to check results before using forces in DroneSim. N44 has now finished but also failed the residuals; read the results for all four grids and the limitations below.
Vocabulary for starting to read the graphs
- Mesh (grid): small cells that divide the fluid region for computation. Passing checkMesh helps check geometric quality but does not confirm that the grid is fine enough.
- Residual: an indicator of the imbalance of the equations the solver is solving. The value shown is the initial residual before each linear-system solution, not a percentage error in force compared with reality.
- Convergence: you must state whether you mean iteration, grid refinement or comparison with experimental results; each requires different evidence.
- y⁺: the distance from the wall in dimensionless form, used to assess near-wall resolution together with wall treatment. No single value suits every model.
- Verification / validation: the former checks how correctly the model is computed; the latter checks how well the model represents what is actually measured.
Start with the figure

The top graph shows force, the middle graph torque and the bottom graph the initial residuals of six separate variables. The colours and names in the legend identify variables; they are not quality scores. The gold dashed line is the mean, and the vertical dotted line divides the data into two halves. The numbers on the horizontal axis are SIMPLE iterations, not seconds so the fluctuation range cannot be converted into a real vibration frequency of the drone.
All lines come from raw data without smoothing. For pressure, which is solved twice per iteration, the maximum residual of that iteration is used. This graph is numerical evidence, not a measurement from a real drone.
How is finishing the program different from converging?
The statement End means that the solver finished running according to its settings, while accepting the result requires checking further criteria. NASA guidance recommends monitoring both residuals and the quantities of interest, such as lift or drag, because each quantity may converge at a different rate (NASA: Iterative Convergence)
The criteria of this study were set in advance: the residuals of all six variables must be below 10⁻⁵ at every iteration over the last 100 iterations, and force and torque must pass both indicators below. These numbers are not international standard values that can automatically be applied to every solver.
Equations used
Let qᵢ be the force or torque at each iteration, with 100 values:
Mean: q̄ = (q₁ + q₂ + … + q₁₀₀) / 100
Fluctuation range: A_pp = (q_max − q_min) / |q̄| × 100%
Difference between halves: D_half = |q̄₅₁:₁₀₀ − q̄₁:₅₀| / |q̄| × 100%
A_pp measures the peak-to-trough fluctuation range relative to the mean, while D_half measures the change in the mean between the first and second halves. The criteria used are A_pp < 2% and D_half < 1% for both force and torque If the mean is close to zero, this ratio is hard to interpret, so a suitable reference scale must be defined in the protocol before use; the scale should not be changed after seeing the results.
| N36 quantity | Mean | A_pp | D_half | Result |
|---|---|---|---|---|
| Force | 2.702727 N | 11.976% | 0.314% | Failed A_pp |
| Resisting torque | 0.0918554 N·m | 4.918% | 2.070% | Failed both |
Force example: (2.8154121841 − 2.4917468178) / 2.702727095717 × 100 = 11.9755%
Although the means of the two halves of the force are close, the graph rises and then falls, which can make the difference between the means small, so the fluctuation range must also be checked. In this case the residuals passed in 0/100 iterations with a maximum of 0.007300501907 so there is evidence of failure on more than one front.
Decision flowchart for students
Having y+ at the final iteration is only a data-completeness criterion in this package; it does not confirm that the wall treatment is appropriate everywhere, and passing per case is still not confirmation of physical accuracy.
Exercises with suggested answers
- If only D_half is considered for the force, how would the judgement go wrong? You might think the force is steady, even though A_pp exceeds the criterion by almost six times.
- N36 finished with exit 0; can its mean be used to compute GCI? Not yet, because the case failed individually, and GCI also requires additional conditions on the grids and convergence behaviour (NASA: Grid Convergence)
- Does this rising and falling graph prove that vortex shedding actually occurs? It does not. SIMPLE iterations are not physical time, and these data cannot yet separate numerical causes from physical behaviour.
- If further study is needed, should the solver settings be changed and the old results simply replaced? No. The original results must be kept, and a new hypothesis and protocol set up before experimenting, so that comparisons remain traceable.
Acceptance checklist before using forces
| What to check | Which file to read | What passing tells you |
|---|---|---|
| Mesh and cell count | summary.json and log.checkMesh in the evidence package | Passes the grid quality criteria for this case |
| Finished at 6,000 with all 8 checkpoint parts complete | final-checkpoint.json and solver-segments.json | A complete finished result according to the protocol, not confirmation of convergence |
| Residuals of all six variables for the full 100 iterations | residuals.csv and layer-solver-summary.json | Passes the specified iterative residual criteria |
| Force and torque pass A_pp and D_half | force.dat, moment.dat | The target quantities are steady according to the chosen window and criteria |
| y⁺ at the final iteration | summary.json | Near-wall data are available for further checking; this does not certify the wall treatment |
| Inputs and grid sequence are comparable | solver-provenance.json and the protocol | A precondition for a grid sensitivity study |
| Comparison with the real experiment | metadata, uncertainty and specimen traceability | Real evidence must still be obtained before physical certification |
Hands-on: Download the Layer mesh package then open the folder results/layers/v3-global36-solver and check the numbers against this table. The current package contains complete results for N30/N32/N36/N44 together with QUICKSTART-TH.md Open the full-size graph or Read the lesson with instructions for regenerating the graphs
Isolating the cause: does increasing the wall function precision help?

The documentation for OpenFOAM: nutUSpaldingWallFunction explains that the near-wall calculation with the Newton method may not give identical results on every restart, so we tried setting maxIter 100 and tolerance 1e-7 compared with the original values. Both cases started from the same N36 checkpoint at iteration 6,000, kept the grid and other solver settings unchanged, and ran to iteration 6,200 with a time limit of 900 seconds per case.
Both actually finished, taking 96 and 94 seconds, but the results for the last 100 iterations still failed the criteria in both cases This adjustment does not solve the problem being investigated:
| What was checked over iterations 6,101–6,200 | Original values | Adjusted wall function | Original criterion |
|---|---|---|---|
| Maximum residual over all equations | 0.00649015 | 0.00649015 | All samples below 0.00001 |
| Mean thrust | 2.024384 N | 2.024382 N | The mean alone is not a pass criterion |
| Thrust fluctuation range ÷ magnitude of the mean | 25.554% | 25.552% | Below 2% |
| Change in mean thrust between the two halves | 12.471% | 12.471% | Below 1% |

Distinguish between the tolerance of the iterative computation inside the wall function from residual criterion for the whole-field solution Making the former smaller does not automatically make the latter pass. In this case, the mean thrust differs by only about 0.00000274 N, but neither solution has converged, so their closeness is not evidence that the force is correct.
This result helps rule out one approach to solving the problem within the tested window. It does not prove a single cause of the fluctuation and does not change the status of the v3 grid set: GCI and grid independence are still not reported. Before computing a new round, the grids, the steady-flow approximation and the convergence evidence should be reviewed together, rather than adding iterations or changing criteria to make the case pass.
Check and reproduce: Thai-language guide · Full numerical results and criteria · Full-size residual graph · Force history of the adjusted case
Further experiment: reducing the size of the velocity update at each iteration

Under-relaxation reduces the size of the change in the solution between iterations. Think of turning a knob a little at a time when a value is oscillating. This approach may make the computation steadier, but it may also merely make the solution move more slowly, so both residuals and forces must be checked, not just a smoother-looking graph.
The experiment on 29 September B.E. 2569 (2026) used two copies of the same N36 checkpoint at iteration 6,000, keeping SIMPLEC and the original grid and changing only the equation relaxation of U from 0.7 to 0.3, then running to iteration 6,600. Both finished within the 600-second limit per case. Iterations 6,501–6,600 were used to read the results, without changing the original acceptance criteria.
| Indicator | relaxation 0.7 | relaxation 0.3 | Original criterion |
|---|---|---|---|
| Maximum initial residual | 0.00730236 | 0.000719718 | All samples < 0.00001 |
| Thrust fluctuation range / absolute mean | 18.3752% | 5.4660% | < 2% |
| Change in mean thrust between window halves | 7.1817% | 2.6950% | < 1% |
| Torque fluctuation range / absolute mean | 3.8550% | 0.5334% | < 2% |
| Overall result for all criteria | Failed | Failed | Must pass all |
Reducing relaxation reduces the fluctuation in the checked window but does not solve the convergence problem and it changes the equation system used to report normalized residuals, so it cannot be interpreted as the error of the original equations decreasing in the same proportion. This round did not separately measure the unrelaxed nonlinear residual, and the sequence of SIMPLE iterations is not physical time, so this fluctuation cannot be used to confirm genuinely unsteady flow.
The graph is smoother, but the mean force still drifts in one direction

When the original data were checked every 100 iterations with windows defined before reading the results the mean thrust of the case U=0.3 decreased from 2.567 to 1.939 newtons continuously over all six windows, or 24.45% relative to the first window. Although the final window looks smoother than the case U=0.7 the mean of the last 100 iterations is still 5.44% lower than the previous window, so it cannot yet be called “converged”. The mean of each window is computed as sum of thrust over 100 iterations ÷ 100 without selecting only the windows that look good after seeing the graph.
| Iterations | U=0.7: mean force (N) | U=0.3: mean force (N) | U=0.3: maximum residual in the window |
|---|---|---|---|
| 6001–6100 | 2.159 | 2.567 | 0.00536209 |
| 6101–6200 | 2.024 | 2.414 | 0.00160609 |
| 6201–6300 | 2.695 | 2.268 | 0.00058433 |
| 6301–6400 | 2.204 | 2.153 | 0.00063519 |
| 6401–6500 | 1.993 | 2.051 | 0.00068942 |
| 6501–6600 | 2.676 | 1.939 | 0.00071972 |
Every window still has residuals above the original criterion 0.00001 and this graph shows only means; it does not replace the force graph at every iteration. Changing relaxation means the normalized residuals of the two cases cannot be compared as errors of the original equations on the same scale. NASA recommends examining both residuals and output quantities while OpenFOAM explains how residuals are normalized These results are used to diagnose numerical trends; they are not real flight time or evidence of physically unsteady flow. Download the complete results and source hashes with re-checking script
Read the guide and reproduction scope, complete numerical results and residual graph The original grid set is still not qualified, and GCI cannot yet be computed nor agreement with the real experiment certified. The download files do not include third-party geometry/mesh.
Reference on OpenFOAM: solution and algorithm control and under-relaxation
Bibliography
-
García-Tíscar et al., On the effect of popular additive manufacturing technologies (AST 169, 2026)
-
UPV, ENOLA numerical and experimental propeller database, v1 (2026)
-
Aular et al., Assessing the Fidelity of Steady-State MRF Modeling (2026)
-
Brandt, Deters, Ananda, Dantsker & Selig, UIUC Propeller Database, Vols 1–4
-
APC, Propeller Geometry Data and archive 202602, file 10x5E-PERF.PE0 checked on 26 September B.E. 2569 (2026)
Original sources checked on 26 September B.E. 2569 (2026); the relaxation experiment was additionally checked on 29 September B.E. 2569 (2026)