When a drone misbehaves, for example it vibrates, drifts, drains its battery quickly or falls, the easiest and most expensive response is to swap parts until the symptom disappears. That wastes money and time and often misses the cause, so the problem comes back. Fault diagnosis finds the cause step by step from evidence, repairs only what caused it, and proves by testing that the fault is gone and nothing new has appeared.

A six-step procedure

  1. Describe the symptom precisely: when it happens, in which mode, at what speed and payload, every time or intermittently. "Flies badly" is not a symptom.
  2. Preserve evidence: download the log, photograph parts and keep the failed part before touching or removing anything.
  3. List hypotheses. An Ishikawa (fishbone) diagram helps you think broadly, for example people, machine, method, material, measurement and environment.
  4. Test from cheap to expensive: start with checks that are quick, non-destructive and eliminate many causes, such as reading the log and checking connectors, before removing motors or replacing the flight controller.
  5. Repair the cause only, following the manufacturer's manual, and record the part numbers removed and fitted.
  6. Test after repair against that aircraft's baseline from when it was healthy, then approve return to service.

A root cause is different from the immediate cause. A cracked propeller is the immediate cause of vibration; the root cause may be propellers stored loose so they knock together. Replacing the propeller alone lets the problem return.

The log as a witness

Flight controllers such as ArduPilot record a great deal during flight. Messages often used in diagnosis:

Log messageWhat it showsSymptoms it helps explain
VIBEVibration on three axes and accelerometer clipping countsShaky video, height oscillation, position drift
RCOUOutput command to each motorOne motor working harder than the others, persistent tilt
BATBattery voltage and currentShort endurance, voltage sag when accelerating
GPS and MAGSatellite quality and magnetic fieldPosition jumps, heading turning by itself
ERR and EVErrors and events such as failsafesMode changes or return-to-home without a command

ArduPilot documentation suggests vibration levels below 30 m/s², and levels above 60 m/s² often cause position and altitude problems. The better habit, though, is to compare with a normal flight of the same aircraft, since each airframe has its own signature. Tools such as UAV Log Viewer plot several values together.

Worked example: short endurance after a motor change

Example: separating battery ageing from a propulsion fault

A pilot reports shorter flights after new motors were fitted. The team opens the BAT messages and reads voltage and current at two moments for the same 6S battery (assumed data): 22.4 V at 20 A in hover and 21.2 V at 48 A in a climb.

  1. Approximate internal resistance R ≈ ΔV / ΔI = (22.4 − 21.2) / (48 − 20) = 1.2 / 28 ≈ 42.9 mΩ.
  2. A reference flight when the battery was new read 22.6 V and 21.9 V at the same currents: R ≈ 0.7 / 28 = 25.0 mΩ.
  3. Resistance rose by about 17.9 mΩ. At 60 A the extra sag is 0.0179 × 60 ≈ 1.07 V, so the low-battery warning arrives sooner.
  4. Hover current, 20 A, is close to the value before the motor change, so there is no evidence the new motors draw more power.

The evidence points to an aged battery, not the motors. The next step is to fly a healthy battery under the same conditions; if endurance returns, the conclusion holds. The estimate is rough, because voltage also depends on state of charge and temperature, so compare moments at similar charge levels.

For an intermittent electrical fault along a harness with many joints, the half-split method cuts the number of measurements: measure in the middle first, then discard the half that is fine. A harness with 16 joints can be narrowed down in about log216 = 4 measurements instead of checking every joint.

Replacing parts and post-repair testing

  • Use parts that match the manual. A motor with a different KV or a different propeller changes response and current.
  • Follow the manufacturer's torque and thread-locking requirements; check motor direction and propeller placement.
  • After replacing a flight controller, compass or GNSS unit, recalibrate and check the configuration.
  • Test in stages: on the ground, then a low hover, then a test pattern. Compare vibration, motor outputs and current with the baseline against criteria set in advance.

Common pitfalls

  • Changing several parts at once, so you never learn which one was at fault.
  • Deleting or overwriting the log before analysis.
  • Concluding from one value, for example passing vibration while current is abnormally high.
  • Having no baseline for each aircraft, so you cannot tell whether a value is abnormal.
  • Closing the job without a root cause, so the fault reappears on another aircraft.

Continue in the lessons

Key references

  1. Federal Aviation Administration. (2023). Aviation maintenance technician handbook – General (FAA-H-8083-30B). link
  2. ArduPilot Dev Team. ArduPilot documentation. link
  3. ArduPilot Dev Team. Onboard message log messages. ArduPilot Copter documentation. link
  4. ArduPilot Dev Team. Measuring vibration. ArduPilot Copter documentation. link
  5. ArduPilot Dev Team. UAV Log Viewer. ArduPilot Copter documentation. link
  6. Ishikawa, K. (1976). Guide to quality control. Asian Productivity Organization. link

Used in courses

How to cite this page

Drone Institute, Rangsit University. (2026). การวิเคราะห์ข้อบกพร่องและการซ่อม. In UAS Technology Knowledge Hub (B.Tech.). https://rsu-uat.pk-research.work/en/kb/new/maint-troubleshooting/