UAT 362 Unmanned Aircraft Systems Technology for Industrial, Energy and Infrastructure Applications

Worksheet 3 Reading thermal patterns on a solar array

Lab 12 hAssesses CLO2, CLO3

Objective

Capture thermal images of a solar array under correct conditions, classify module- and string-level anomalies and confirm with other data

Equipment and materials

  • Drone or thermal camera kit with a colour camera
  • Irradiance meter, thermometer and anemometer
  • String layout and inverter current data from the system operator
  • Python and the module 3 example code
  • Lab notebook

Safety

  • Fly within CAAT conditions in visual line of sight and coordinate with the operator before entering
  • Do not touch modules, cables or DC equipment; work under the operator's supervision
  • Beware of sun heat; drink water and rest in shade

Steps

  1. Take thermal images on a sunny day, recording irradiance, air temperature and wind
  2. Tabulate module temperatures by the real string layout
  3. Use Example 1 to classify module- and string-level anomalies with criteria set before viewing results
  4. Confirm findings with colour images and inverter current data
  5. Write a findings list with module positions, possible causes and follow-up checks

Record of results

Table 1 Conditions during capture
TimeIrradiance (W/m²)Air temperature (°C)Wind speed (m/s)Thermal and colour image numbers
Table 2 String temperatures and abnormal modules
StringString median (°C)Difference from array median (K)Modules above string median by the criterion (K)Inverter current (A)Anomaly level
Table 3 Findings list
Position (string-module)Thermal patternPossible causeConfirmation (colour image, current)Follow-up check

Questions

  1. In Table 2, which string is warm as a whole and which module is hot on its own? What should the repair team check first in each case?

  2. If each module were compared only with the whole-array median, using the same 5 K criterion, how would your results change?

  3. Why must the 2 K and 5 K criteria (or your group's) be set before viewing the results? What happens to the report if they are set afterwards?

  4. Does the inverter current data confirm or contradict what the thermal images show? If they disagree, what will your group do next?

  5. How could the conditions in Table 1 (sunlight, wind, time) make your images misleading, and why does real work need the criteria from the actual IEC TS 62446-3?

Check before you hand in

What to hand in

  • Thermal images with conditions
  • Module temperature table
  • Anomaly classification
  • Findings list

CLO2 Use optical, thermal and LiDAR sensing to detect deterioration. CLO3 Assess risk and report inspections. (CLOs are a web-team draft; the course owner sets the final ones.)