UAT 453 UAS for Infrastructure, Energy and Utility Inspection
Worksheet 14 Severity grading and remaining life
Objective
Grade findings, compute remaining life and intervals, and compare data over time critically
Equipment and materials
- Group findings from module 13
- Pipe thickness data for 5 points over 3 years from the lecturer
- Drone with camera and the module 12 wall
- Python and module 14 example code
Safety
- Fly within CAAT conditions in visual line of sight at the same standoff
- Keep people clear
- Inspect batteries before flight; keep them in fire-safe bags or boxes
Steps
- Grade module 13 findings A–D with reasons from condition and location
- Compute pipe remaining life and intervals with Example 1
- Rank the points to inspect first
- Re-photograph the wall at another time with the same distance and angle
- Compare percent rust with Example 2
- Explain whether differences are real change or come from light and collection
Record of results
| Finding | Condition found | Importance of location | Grade A-D | Action |
|---|---|---|---|---|
| Point | Long-term rate (mm/yr) | Short-term rate (mm/yr) | Remaining life (yr) | Next inspection within (yr) | Rank |
|---|---|---|---|---|---|
| Image code | First percent rusted (grade) | Second percent rusted (grade) | Same light, time, distance? | Interpretation |
|---|---|---|---|---|
Questions
Which finding did you grade higher because of its location rather than its condition? Explain.
Which point has a short-term rate above its long-term rate, what does that tell you, and why use the higher rate?
Is the difference in rusted area you found real change or due to light and data collection? Use Table 3.
With 11.5 years of remaining life and a Class 1 pipe under API 570, within how many years is the next inspection due, and why?
Check before you hand in
What to hand in
- Graded findings table
- Remaining life, interval and ranking table
- Two-time comparison with interpretation