UAT 454 UAS for Surveillance, Monitoring and Security
Worksheet 3 Working-range test of EO and thermal cameras
Objective
Measure real pixel density on targets against calculations and conclude each camera's detection range
Equipment and materials
- Drone or tripod with EO and thermal cameras
- 1 m target board
- Tray of hot charcoal or a controlled heat source
- Tape measure or GNSS
- Fire extinguisher
Safety
- The lecturer supervises the heat source; extinguisher ready
- Fly within CAAT conditions in visual line of sight; keep people clear
- Do not capture outsiders at identification level
Steps
- Compute IFOV and pixels on target at 50, 100, 200 m
- Set up targets and measure distances
- Record EO and thermal images at each distance
- Count pixels on targets in the real images
- Compare with calculations and conclude detection ranges
Record of results
| Range (m) | Thermal ground pixel (m) | Pixels on 1 m target (thermal) | EO px/m | Expected DORI level |
|---|---|---|---|---|
| Range (m) and camera | Pixels counted on target | Calculated | Difference (%) | Charcoal still detected or sign detail visible? |
|---|---|---|---|---|
Questions
Why are counted pixels usually fewer than calculated? Name the causes found in your group's test.
If the camera is on a drone 60 m high and 100 m horizontally from the target, which range should be used, and how much does the pixel count change?
Why can hot charcoal still be detected by the thermal camera when it covers few pixels, while the sign needs many more pixels to show detail?
If the mission only needs to know whether anyone is near the fire, which DORI level should be the target, and to what range can the wide EO camera achieve it?
Check before you hand in
What to hand in
- Calculated versus measured table
- Test images labelled by distance
- Conclusions and reasons for differences