Module 15/15 · Weeks 15 · 9 h

Inspection reporting

UAT 453 UAS for Infrastructure, Energy and Utility Inspection

About 80 minDraft, awaiting reviewLast updated 30 September 2026

Lesson

By the end of this module you will be able to

  1. Structure an inspection report that managers, maintenance and reviewers can use
  2. Evaluate automatic detectors with precision and recall
  3. Report inspection coverage and limitations honestly
  4. Build a traceability chain from finding to source data

Prerequisites: Module 14 Severity grading and temporal comparison

Why this matters

The report is the only thing the client actually receives from an inspection. Thousands of fine images are useless if the report does not say what to repair first, and a report that hides its limitations may lead managers to think an asset is safe when parts were never inspected. This module brings the whole course together into a report that is easy to read and can be traced.

Report structure

Six boxes joined by arrows: Executive summary, Scope and method, Findings by asset, Severity and actions, Limitations and Data appendix
Figure 1 Inspection report structure
SectionMain readerContent
Executive summaryPlant managerOne page: grade A and B findings, decisions needed, budget and time
Scope and methodReviewerAssets inspected and not inspected, equipment, GSD, dates, weather, inspectors and qualifications
Findings by assetMaintenanceFindings with asset location, images, measured values and grades
Severity and actionsMaintenance and planningTable sorted by grade, actions, deadlines and next inspection
LimitationsEveryoneAreas with no images, blurred images, what this method cannot detect
Data appendixReviewers and next yearFile list, hashes, flight logs, detector settings

Report language must separate what was seen from assumptions. “A 1.80% rusted area was found on panel C5-R2” is an observation; “probably caused by rainwater collecting at the ring” is an assumption that must be stated as unconfirmed.

Performance of automatic detectors

If the report uses an automatic detector for screening, it must say how accurate it is, measured by having an inspector review the same images.

  • Precision: of the spots the detector flagged, how many were real; if low, inspectors waste time chasing false spots
  • Recall: of all real spots, how many the detector found; if low, spots are missed without anyone knowing unless an inspector reviews

Example 1 How accurate is the rust detector?

The detector flagged 60 rust spots on the tank shell. The inspector confirmed 48; the other 12 were stains and welds. The inspector also found 12 spots the detector missed.

# automatic rust detector results versus inspector review
tp, fp, fn = 48, 12, 12                 # agreed, false detections, missed

precision = tp / (tp + fp)
recall = tp / (tp + fn)
print(f"precision {precision:.0%}, recall {recall:.0%}")
print(f"spots the inspector added by hand: {fn}")
precision 80%, recall 80%
spots the inspector added by hand: 12

Precision and recall are both 80%, meaning the detector alone would miss about 1 in 5 rust spots. The report must therefore state that every image was reviewed by an inspector, and record the detector version and settings in the appendix so next year can be compared.

Coverage and limitations

Readers often take “no damage found” to mean “no damage”, when it may mean “not looked at”. The report must give coverage as a number and state where was not inspected.

Example 2 Was the whole tank shell inspected?

The plan had 44 images; 2 were blurred by gusts and 1 was blocked by the spiral stair.

# image coverage of the tank shell
planned, blurred, occluded = 44, 2, 1   # planned images, blurred, hidden by the stair

usable = planned - blurred - occluded
print(f"usable images {usable}/{planned} = {usable / planned:.1%}")
print("limitations to report:", blurred, "blurred,", occluded, "occluded by the stair")
usable images 41/44 = 93.2%
limitations to report: 2 blurred, 1 occluded by the stair

41 of 44 images, or 93.2%, are usable. The report must list the unusable images, recommend a visual check from the stair for the blocked part during this shutdown, and state that all findings apply to the outer surface only; they say nothing about the tank floor or inner wall.

Traceability chain

Every finding must trace back to its source data. A reviewer or next year’s team should be able to start from a finding, then open the image, the original file, check its SHA-256 hash, and see the flight log with time, position and camera settings straight away.

Five boxes joined by arrows: Finding C5-R2, Image IMG_0231, Original file, SHA-256 and Flight log
Figure 2 Traceability chain from finding to source data

A matching hash proves the file has not changed since it was recorded, but not that the interpretation is correct. Correct interpretation comes from transparent methods, qualified inspectors and review. Each report version should carry a version number, date and change log.

Module lab

Lab: writing a complete inspection report

  1. Combine your group’s results from modules 11–14 into a report following this structure, with an executive summary of no more than one page
  2. Have another group review the same images, then compute the precision and recall of your group’s inspection with the code in Example 1
  3. Compute coverage with the code in Example 2 and write the limitations section
  4. Swap reports with another group, pick 3 findings at random and trace each back to its original file and hash

Common mistakes

Watch out

  • A long, jargon-filled executive summary that decision-makers do not finish
  • Mixing observations with assumptions
  • Not stating the detector’s accuracy, or that an inspector reviewed the results
  • Writing “no damage found” for areas with no images
  • Findings that cannot be traced back to images and original files

Summary

  • A report has an executive summary, scope and method, findings by asset, severity and actions, limitations and a data appendix
  • Automatic detectors need reported precision and recall, and inspector review
  • Coverage must be a number, with locations and damage types the method cannot detect stated
  • Every finding must trace back to images, original files, hashes and flight logs

Check your understanding

  1. A detector flagged 50 spots, 40 of them real. What is precision?
  2. There are 64 real spots in total and the detector found 40. What is recall?
  3. 57 of 60 planned images are usable. What is coverage?
  4. How should “probably caused by standing rainwater” be written in the report?
  5. What does a matching hash prove, and what does it not prove?
Answers
  1. State clearly that it is an unconfirmed assumption, separate from observations, and propose how to confirm it
  2. It proves the file has not changed since recording, but not that the interpretation is correct

Key formulas

Precision
Recall
Image coverage

Key references

  1. Barnhart, R. K., Marshall, D. M., & Shappee, E. (Eds.). (2021). Introduction to unmanned aircraft systems (3rd ed.). CRC Press. link
  2. American Petroleum Institute. (2023). Elements of a risk-based inspection program (API RP 580, 4th ed.). link
  3. International Organization for Standardization. (2024). Asset management — Vocabulary, overview and principles (ISO 55000:2024). link
  4. ASTM International. (2025). Standard practice for evaluating degree of rusting on painted steel surfaces (ASTM D610-25). link

Further reading

Study the assigned knowledge units in advance, review media and take the module quiz

In class / field

Lab or field practice from worksheets with a safety checklist

Learning evidence: Checked worksheets and quiz results

Module quiz

This is a formative self-check, not a graded exam

Knowledge domain: Law, safety and risk · Management, innovation and professional practice · Artificial intelligence and computer vision · Surveying, mapping and geoinformatics · Public safety and disasters · Inspection, industry and surveillance