ระบบจ่ายกำลังของ UAS

LiPo/Li-ion batteries, PDB, BEC, wire gauge, connectors and current sensing

Last updated:

Why it matters

The power distribution system of an electric drone is everything between the battery and the loads: the battery, connectors, wires, power distribution board, voltage regulators and the voltage and current sensors. It does two jobs at once. It delivers hundreds of watts to the motors, and it feeds avionics that use only tens of watts but must never flicker. Fail at the first and the aircraft lacks thrust or burns a wire. Fail at the second and the flight controller resets in the air.

This page gives an overview of each component, how to read the numbers on its datasheet, and how current is measured. Power budgets, wire sizing and rail current budgets are worked through in detail in the lessons linked at the end.

LiPo and Li-ion batteries

Almost every electric drone uses lithium cells, in two main families.

  • LiPo (lithium polymer) cells come in soft pouches and deliver high current well. According to Grepow, a standard LiPo cell is 3.7 V nominal, 4.2 V fully charged, should not be discharged below 3.0 V, and is stored at 3.7–3.85 V per cell.
  • Li-ion cylindrical cells, such as the 21700 size, hold more energy per kilogram but deliver less peak current, so they suit fixed-wing and VTOL aircraft that fly long. For example, Molicel specifies the INR-21700-P45B at 3.6 V, 4.5 Ah (16.2 Wh), 45 A maximum discharge and at most 13.8 mΩ internal resistance.

Packs are named by cell arrangement. S (series) is the number of cells in series, which sets voltage; P (parallel) is the number in parallel, which adds capacity and current. A 6S LiPo pack is therefore 6 × 3.7 = 22.2 V nominal and 25.2 V full. A LiPo's C-rating gives maximum continuous current as a multiple of capacity: a 5 Ah pack rated 25C can supply 25 × 5 = 125 A, following Grepow's explanation. The figure is self-declared by the maker, so leave margin and check pack temperature after flight.

Internal resistance is the resistance inside the cell itself. Under load the terminal voltage drops (voltage sag) and the cell heats by I2R. Internal resistance rises as cells age or get cold, which is why old packs often trip a low-voltage failsafe early during a climb.

Example 1: a 6S2P Li-ion pack for a VTOL

A team builds a 6S2P pack from P45B cells (12 cells). Values come from the maker's datasheet; tab and lead resistance are ignored.

ItemWorkingResult
Nominal voltage6 × 3.6 V21.6 V
Capacity2 × 4.5 Ah9.0 Ah
Energy12 × 16.2 Wh194.4 Wh
Datasheet maximum current2 × 45 A90 A
Worst-case internal resistance6 × 13.8 mΩ / 241.4 mΩ
Sag at 30 A30 × 0.04141.24 V (5.8%), 37 W of heat
Sag at 60 A60 × 0.04142.48 V (11.5%), 149 W of heat

The pack suits cruise at moderate current. If vertical take-off draws 60 A, the voltage sags by almost 2.5 V and the pack gets very hot. Set the failsafe with this sag in mind, or move to 6S3P.

From battery to load

  • Power distribution board (PDB). Splits battery power to the ESCs and regulators, and must carry the aircraft's total peak current.
  • BEC (battery eliminator circuit). A switching regulator that steps battery voltage down to 5 V or 12 V for other devices. The current drawn from the battery is Iin = Pout / (η × Vin), where η is efficiency. A BEC must tolerate full-charge battery voltage and be rated above peak load.
  • Power module. ArduPilot's documentation lists three roles: a stable supply for the flight controller that reduces the chance of brown-out, battery voltage and current monitoring for the failsafe, and current data for compensating motor interference on the compass. Both analogue types and digital types (I2C or DroneCAN) exist.
  • Wires and connectors. Size wires by voltage drop and heating, counting both outgoing and return length. Take connector ratings from the maker's datasheet, not from the number in the model name.

ArduPilot's page on powering the Pixhawk stresses a few rules: the flight controller does not power the servo rail, two BECs must not be paralleled directly, and the flight controller should have a backup supply. Read the page for your exact board before first power-up.

Measuring current and voltage

The flight controller needs current to count the capacity used and voltage to watch the battery. Two current-sensing methods are common.

  • Shunt resistor. A very small resistor in the current path. The voltage across it, V = IR, is amplified and fed to an ADC. Accurate and cheap, but it dissipates I2R and is not isolated.
  • Hall-effect sensor. Measures the magnetic field around the conductor. Isolated and nearly lossless, but its zero point can drift with temperature.

An analogue power module outputs two scaled voltages, and the flight controller converts them back with multipliers. In ArduPilot these are BATT_VOLT_MULT for voltage and BATT_AMP_PERVLT with BATT_AMP_OFFSET for current. Defaults are only approximate: calibrate against a multimeter and a clamp meter before basing a capacity failsafe on them.

Example 2: a shunt and a current calibration

A 0.25 mΩ shunt at 100 A produces 100 × 0.00025 = 25 mV and dissipates 1002 × 0.00025 = 2.5 W. At 20 A it gives 5 mV and 0.1 W. Signals of a few millivolts are why an amplifier is needed and why power-module signal leads must stay away from high-current wires.

After a flight the flight controller reports 3,600 mAh used, but the charger puts back 4,000 mAh (assumed values). Following ArduPilot's procedure, the new BATT_AMP_PERVLT is the old value times 4,000 / 3,600 ≈ 1.11; an old value of 36.36 becomes about 40.4. Left uncorrected, the system believes it has about 11% more energy than it does, and the failsafe warns too late.

Common pitfalls

  • Using average instead of peak current when choosing BECs, wires and connectors.
  • Forgetting full-charge voltage when choosing a regulator: a full 6S pack is 25.2 V, not 22.2 V.
  • Trusting a C-rating or a connector's model number without datasheet checks and temperature measurements.
  • Setting a capacity failsafe on an uncalibrated power module.
  • Paralleling BECs directly, or powering the flight controller from the servo rail.
  • Charging and storing packs carelessly. Balance-charge on a fire-resistant surface with a charger rated for Thai mains (230 V, 50 Hz), and store at storage voltage when idle for several days.

Continue in the lessons

Key references

  1. Grepow. What is the voltage of a LiPo battery? link
  2. Grepow. What is the C rating on a LiPo battery? link
  3. Molicel. INR-21700-P45B lithium-ion cell specification. link
  4. ArduPilot Dev Team. Power module / battery monitor. ArduPilot Copter documentation. link
  5. ArduPilot Dev Team. Powering the Pixhawk. ArduPilot Copter documentation. link
  6. ArduPilot Dev Team. Battery failsafe (Copter documentation). link

Used in courses

How to cite this page

Drone Institute, Rangsit University. (2026). ระบบจ่ายกำลังของ UAS. In UAS Technology Knowledge Hub (B.Tech.). https://rsu-uat.pk-research.work/en/kb/new/uas-power-system/